메뉴 건너뛰기




Volumn 92, Issue 4, 2013, Pages 517-521

Does venous blood gas analysis provide accurate estimates of hemoglobin oxygen affinity?

Author keywords

Diagnosis; Erythrocytosis; Hemoglobin; Oxygen affinity; Polycythemia

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD GAS ANALYSIS; BLOOD SAMPLING; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE ASSOCIATION; ERYTHROCYTOSIS; FEMALE; HUMAN; MALE; OUTCOME ASSESSMENT; OXYGEN AFFINITY; OXYGEN SATURATION; OXYGEN TENSION; PH MEASUREMENT; PREDICTIVE VALUE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; TONOMETRY; VENOUS BLOOD GAS ANALYSIS; CHEMISTRY; ENZYME SPECIFICITY; EVALUATION; METABOLISM; METHODOLOGY; MIDDLE AGED; OXIMETRY; PROTEIN BINDING; VEIN;

EID: 84877044371     PISSN: 09395555     EISSN: 14320584     Source Type: Journal    
DOI: 10.1007/s00277-012-1667-z     Document Type: Article
Times cited : (12)

References (11)
  • 2
    • 34548152255 scopus 로고    scopus 로고
    • Amendment to the guideline for diagnosis and investigation of polycythaemia/erythrozytosis
    • National Cancer Research Institute Myeloproliferative Disorder Subgroup British Committee for Standards in Haematology 10.1111/j.1365-2141.2007.06741.x
    • McMullin MF, Reilly JT, Campbell P, Bareford D, Green AR, Harrison CN, Conneally E, National Cancer Research Institute, Myeloproliferative Disorder Subgroup, Ryan K, British Committee for Standards in Haematology (2007) Amendment to the guideline for diagnosis and investigation of polycythaemia/erythrozytosis. B J Haematol 138:812-823
    • (2007) B J Haematol , vol.138 , pp. 812-823
    • McMullin, M.F.1    Reilly, J.T.2    Campbell, P.3    Bareford, D.4    Green, A.R.5    Harrison, C.N.6    Conneally, E.7    Ryan, K.8
  • 3
    • 0032587023 scopus 로고    scopus 로고
    • Hb Schlierbach or β108(G10)Asn→Ile: A new variant with low oxygen affinity detected in a Swiss family
    • 10081990 10.3109/03630269908996152 1:CAS:528:DyaK1MXhsF2isbo%3D
    • Frischknecht H, Speich R, Bloch KE, Fehr J, Tuchschmid P, Jenni R (1999) Hb Schlierbach or β108(G10)Asn→Ile: a new variant with low oxygen affinity detected in a Swiss family. Hemoglobin 23(1):83-87
    • (1999) Hemoglobin , vol.23 , Issue.1 , pp. 83-87
    • Frischknecht, H.1    Speich, R.2    Bloch, K.E.3    Fehr, J.4    Tuchschmid, P.5    Jenni, R.6
  • 4
    • 84879498006 scopus 로고    scopus 로고
    • UpToDate Accessed 11 Dec 2012
    • Steinberg MH (2012) Genetic disorders of haemoglobin oxygen affinity. UpToDate. http://www.uptodate.com/contents/genetic-disorders-of-hemoglobin- oxygen-affinity?source=search-result&search=haemoglobin+oxygen+affinity& selectedTitle=2%7E150, Accessed 11 Dec 2012
    • (2012) Genetic Disorders of Haemoglobin Oxygen Affinity
    • Steinberg, M.H.1
  • 5
    • 0018399378 scopus 로고
    • 2 dissociation computations
    • 35496 1:STN:280:DyaE1M7nt1Krtg%3D%3D
    • 2 dissociation computations. J Appl Physiol 46(3):599-602
    • (1979) J Appl Physiol , vol.46 , Issue.3 , pp. 599-602
    • Severinghaus, J.W.1
  • 8
    • 0028817948 scopus 로고
    • Performance characteristics of Hemox-Analyzer for assessment of the hemoglobin dissociation curve
    • Guarnone R, Centenara E, Barosi G (1979) Performance characteristics of Hemox-Analyzer for assessment of the hemoglobin dissociation curve. Haematologica 80(5):426-430
    • (1979) Haematologica , vol.80 , Issue.5 , pp. 426-430
    • Guarnone, R.1    Centenara, E.2    Barosi, G.3
  • 9
    • 0025690785 scopus 로고
    • Arterial oxygen status determined with routine pH/blood gas equipment and multi-wavelength hemoximetry: Reference values, precision and accuracy
    • 10.3109/00365519009087492 1:CAS:528:DyaK3MXlsFCgurg%3D
    • Siggaard-Andersen O, Wimberley PD, Fogh-Andersen N, Gøthgen IH (1990) Arterial oxygen status determined with routine pH/blood gas equipment and multi-wavelength hemoximetry: reference values, precision and accuracy. Scand J Clin Lab Invest 50(Suppl 203):57-66
    • (1990) Scand J Clin Lab Invest , vol.50 , Issue.SUPPL. 203 , pp. 57-66
    • Siggaard-Andersen, O.1    Wimberley, P.D.2    Fogh-Andersen, N.3    Gøthgen, I.H.4
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet 1(8476):307-310
    • (1986) The Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.