메뉴 건너뛰기




Volumn 183, Issue , 2013, Pages 381-387

NiO-decorated single-walled carbon nanotubes for high-performance nonenzymatic glucose sensing

Author keywords

Glucose sensing; Nanoparticles; Nickel oxide; Single walled carbon nanotubes

Indexed keywords

AMPEROMETRIC RESPONSE; ARC-DISCHARGE METHOD; COATED GLASS SUBSTRATES; CRYSTALLINE STRUCTURE; CYCLIC VOLTAMMOGRAMS; ELECTROCATALYTIC BEHAVIOR; ELECTROCHEMICAL METHODS; GLUCOSE SENSING;

EID: 84877021355     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.04.018     Document Type: Article
Times cited : (73)

References (25)
  • 1
  • 2
    • 0026216348 scopus 로고
    • Design an in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
    • D.S. Bindra, Y. Zhang, and G.S. Wilson Design an in vitro studies of a needle-type glucose sensor for subcutaneous monitoring Analytical Chemistry 63 1991 1692 1696
    • (1991) Analytical Chemistry , vol.63 , pp. 1692-1696
    • Bindra, D.S.1    Zhang, Y.2    Wilson, G.S.3
  • 3
    • 84155165112 scopus 로고    scopus 로고
    • A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode
    • J. Luo, S. Jiang, H. Zhang, J. Jiang, and X. Liu A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode Analytica Chimica Acta 709 2012 47 53
    • (2012) Analytica Chimica Acta , vol.709 , pp. 47-53
    • Luo, J.1    Jiang, S.2    Zhang, H.3    Jiang, J.4    Liu, X.5
  • 5
    • 62649166821 scopus 로고    scopus 로고
    • Design and fabrication of nickel microdisk-arrayed diamond electrodes for a non-enzymatic glucose sensor based on control of diffusion profiles
    • T. Watanabe, and Y. Einaga Design and fabrication of nickel microdisk-arrayed diamond electrodes for a non-enzymatic glucose sensor based on control of diffusion profiles Biosensors & Bioelectronics 24 2009 2684 2689
    • (2009) Biosensors & Bioelectronics , vol.24 , pp. 2684-2689
    • Watanabe, T.1    Einaga, Y.2
  • 6
    • 70349253893 scopus 로고    scopus 로고
    • Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection
    • S. Cherevko, and C.H. Chung Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection Sensors and Actuators B 142 2009 216 223
    • (2009) Sensors and Actuators B , vol.142 , pp. 216-223
    • Cherevko, S.1    Chung, C.H.2
  • 7
    • 43749100910 scopus 로고    scopus 로고
    • Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes
    • C. Batchelor-McAuley, G.G. Wildgoose, R.G. Compton, L. Shao, and M.L.H Green Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes Sensors and Actuators B 132 2008 356 360
    • (2008) Sensors and Actuators B , vol.132 , pp. 356-360
    • Batchelor-Mcauley, C.1    Wildgoose, G.G.2    Compton, R.G.3    Shao, L.4    Green, L.H.5
  • 8
    • 67349158670 scopus 로고    scopus 로고
    • Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode
    • Y. Liu, H. Teng, H. Hou, and T. You Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode Biosensors and Bioelectronics 24 2009 3329 3334
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 3329-3334
    • Liu, Y.1    Teng, H.2    Hou, H.3    You, T.4
  • 9
    • 84871659216 scopus 로고    scopus 로고
    • A high-performance nonenzymatic glucose sensor made of CuO-SWCNT nanocomposites
    • N.Q. Dung, D. Patil, H. Jung, and D.J. Kim A high-performance nonenzymatic glucose sensor made of CuO-SWCNT nanocomposites Biosensors and Bioelectronics 42 2013 280 286
    • (2013) Biosensors and Bioelectronics , vol.42 , pp. 280-286
    • Dung, N.Q.1    Patil, D.2    Jung, H.3    Kim, D.J.4
  • 10
    • 77953325233 scopus 로고    scopus 로고
    • The non-enzymatic determination of glucose using an electrolytically fabricated nickel microparticle modified boron-doped diamond electrode or nickel foil electrode
    • K.E. Toghill, L. Xiao, M.A. Phillips, and R.G. Compton The non-enzymatic determination of glucose using an electrolytically fabricated nickel microparticle modified boron-doped diamond electrode or nickel foil electrode Sensors and Actuators B 147 2010 642 652
    • (2010) Sensors and Actuators B , vol.147 , pp. 642-652
    • Toghill, K.E.1    Xiao, L.2    Phillips, M.A.3    Compton, R.G.4
  • 11
    • 84857373416 scopus 로고    scopus 로고
    • A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in ionic liquids
    • A. Sun, J. Zheng, and Q. Sheng A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in ionic liquids Electrochimica Acta 65 2012 64 69
    • (2012) Electrochimica Acta , vol.65 , pp. 64-69
    • Sun, A.1    Zheng, J.2    Sheng, Q.3
  • 12
    • 68049120171 scopus 로고    scopus 로고
    • A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: Enhancing sensitivity through a nanowire array strategy
    • L. Lu, L. Zhang, F.L. Qu, H.X. Lu, X.B. Zhang, Z.S. Wu, S.Y. Huan, Q.A. Wang, G.L. Shen, and R.Q. Yu A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: Enhancing sensitivity through a nanowire array strategy Biosensors & Bioelectronics 25 2009 218 223
    • (2009) Biosensors & Bioelectronics , vol.25 , pp. 218-223
    • Lu, L.1    Zhang, L.2    Qu, F.L.3    Lu, H.X.4    Zhang, X.B.5    Wu, Z.S.6    Huan, S.Y.7    Wang, Q.A.8    Shen, G.L.9    Yu, R.Q.10
  • 13
    • 57949096141 scopus 로고    scopus 로고
    • Porous single-wall carbon nanotube films formed by in Situ arc-discharge deposition for gas sensors application
    • N.D. Hoa, N.V. Quy, Y. Cho, and D.J. Kim Porous single-wall carbon nanotube films formed by in Situ arc-discharge deposition for gas sensors application Sensors and Actuators B 135 2009 656 663
    • (2009) Sensors and Actuators B , vol.135 , pp. 656-663
    • Hoa, N.D.1    Quy, N.V.2    Cho, Y.3    Kim, D.J.4
  • 16
    • 84863340067 scopus 로고    scopus 로고
    • Realization of an open space ensemble for nanowires: A strategy for the maximum response in resistive sensors
    • N.M. Vuong, H. Jung, D.J. Kim, H.J. Kim, and S.K. Hong Realization of an open space ensemble for nanowires: a strategy for the maximum response in resistive sensors Journal of Materials Chemistry 22 2012 6716
    • (2012) Journal of Materials Chemistry , vol.22 , pp. 6716
    • Vuong, N.M.1    Jung, H.2    Kim, D.J.3    Kim, H.J.4    Hong, S.K.5
  • 17
    • 84862832369 scopus 로고    scopus 로고
    • An amperometric glucose biosensor based on a GOx-entrapped TiO2-SWCNT composite
    • N.Q. Dung, D. Patil, T.T. Duong, H. Jung, D.J. Kim, and S.G. Yoon An amperometric glucose biosensor based on a GOx-entrapped TiO2-SWCNT composite Sensors and Actuators B 166-167 2012 103 109
    • (2012) Sensors and Actuators B , vol.166-167 , pp. 103-109
    • Dung, N.Q.1    Patil, D.2    Duong, T.T.3    Jung, H.4    Kim, D.J.5    Yoon, S.G.6
  • 18
    • 80053319823 scopus 로고    scopus 로고
    • 3 nanowire arrays
    • 3 nanowire arrays Analyst 136 2011 4241 4246
    • (2011) Analyst , vol.136 , pp. 4241-4246
    • Cao, X.1    Wang, N.2
  • 19
    • 0032638325 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of methanol at a nickel hydroxide/glassy carbon modified electrode in alkaline medium
    • A.A. El-Shafei Electrocatalytic oxidation of methanol at a nickel hydroxide/glassy carbon modified electrode in alkaline medium Journal of Electroanalytical Chemistry 471 1999 89 95
    • (1999) Journal of Electroanalytical Chemistry , vol.471 , pp. 89-95
    • El-Shafei, A.A.1
  • 20
    • 34248200455 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of cyclohexanol on a nickel oxyhydroxide modified nickel electrode in alkaline solutions
    • Q. Yi, J. Zhang, W. Huang, and X. Liu Electrocatalytic oxidation of cyclohexanol on a nickel oxyhydroxide modified nickel electrode in alkaline solutions Catalysis Communications 8 2007 1017 1022
    • (2007) Catalysis Communications , vol.8 , pp. 1017-1022
    • Yi, Q.1    Zhang, J.2    Huang, W.3    Liu, X.4
  • 21
    • 74449089230 scopus 로고    scopus 로고
    • Highly improved electrooxidation of glucose at a nickel(II) oxide/multi-walled carbon nanotube modified glassy carbon electrode
    • M. Shamsipur, M. Najafi, and M.M. Hosseini Highly improved electrooxidation of glucose at a nickel(II) oxide/multi-walled carbon nanotube modified glassy carbon electrode Bioelectrochemistry 77 2010 120 124
    • (2010) Bioelectrochemistry , vol.77 , pp. 120-124
    • Shamsipur, M.1    Najafi, M.2    Hosseini, M.M.3
  • 22
    • 79551510866 scopus 로고    scopus 로고
    • Nonenzymatic electrochemical glucose sensor based on novel copper film
    • F. Sun, L. Li, P. Liu, and Y. Lian Nonenzymatic electrochemical glucose sensor based on novel copper film Electroanalysis 23 2011 395 401
    • (2011) Electroanalysis , vol.23 , pp. 395-401
    • Sun, F.1    Li, L.2    Liu, P.3    Lian, Y.4
  • 23
    • 33244496199 scopus 로고    scopus 로고
    • Preparation of functionalized copper nanoparticles and fabrication of a glucose sensor
    • Q. Xu, Y. Zhao, J.Z. Xu, and J.J. Zhu Preparation of functionalized copper nanoparticles and fabrication of a glucose sensor Sensors and Actuators B: Chemical 114 2006 379 386
    • (2006) Sensors and Actuators B: Chemical , vol.114 , pp. 379-386
    • Xu, Q.1    Zhao, Y.2    Xu, J.Z.3    Zhu, J.J.4
  • 24
    • 55849150929 scopus 로고    scopus 로고
    • CuO nanospheres based nonezymatic glucose sensor
    • E. Reitz, W. Jia, M. Gentile, Y. Ming, and Y. Lei CuO nanospheres based nonezymatic glucose sensor Electroanalysis 20 2008 2482 2486
    • (2008) Electroanalysis , vol.20 , pp. 2482-2486
    • Reitz, E.1    Jia, W.2    Gentile, M.3    Ming, Y.4    Lei, Y.5
  • 25
    • 55249083796 scopus 로고    scopus 로고
    • Fabrication and optimization of a nanoporous platinum electrode and a non-enzymatic glucose micro-sensor on silicon
    • Y.J. Lee, D.J. Park, J.Y. Park, and Y.H. Kim Fabrication and optimization of a nanoporous platinum electrode and a non-enzymatic glucose micro-sensor on silicon Sensors 8 2008 6154 6164
    • (2008) Sensors , vol.8 , pp. 6154-6164
    • Lee, Y.J.1    Park, D.J.2    Park, J.Y.3    Kim, Y.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.