메뉴 건너뛰기




Volumn 4, Issue 2, 2013, Pages 183-191

A Novel Acquisition Technique to Utilize Swan-Ganz Catheter data as a Surrogate for High-fidelity Micromanometry within the Right Ventricle and Pulmonary Circuit

Author keywords

Catheter; Hemodynamics; Pulmonary arterial pressure; Right heart catheterization; Right ventricular pressure

Indexed keywords

CATHETERS; DATA ACQUISITION; DIAGNOSIS; HEART; HEMODYNAMICS; TIMING CIRCUITS;

EID: 84877016847     PISSN: 1869408X     EISSN: 18694098     Source Type: Journal    
DOI: 10.1007/s13239-013-0124-z     Document Type: Article
Times cited : (14)

References (6)
  • 1
    • 70349776690 scopus 로고    scopus 로고
    • Comprehensive invasive and noninvasive approach to the right ventricle-pulmonary circulation unit: state of the art and clinical and research implications
    • Champion, H. C., E. D. Michelakis, and P. M. Hassoun. Comprehensive invasive and noninvasive approach to the right ventricle-pulmonary circulation unit: state of the art and clinical and research implications. Circulation 120(11): 992-1007, 2009.
    • (2009) Circulation , vol.120 , Issue.11 , pp. 992-1007
    • Champion, H.C.1    Michelakis, E.D.2    Hassoun, P.M.3
  • 2
    • 0015986786 scopus 로고
    • Analysis and correction of pressure wave distortion in fluid-filled catheter systems
    • Falsetti, H. L., et al. Analysis and correction of pressure wave distortion in fluid-filled catheter systems. Circulation 49(1): 165-172, 1974.
    • (1974) Circulation , vol.49 , Issue.1 , pp. 165-172
    • Falsetti, H.L.1
  • 3
    • 0015579398 scopus 로고
    • In vivo comparison of catheter manometer systems with the catheter-tip micromanometer
    • Gould, K. L., S. Trenholme, and J. W. Kennedy. In vivo comparison of catheter manometer systems with the catheter-tip micromanometer. J. Appl. Physiol. 34(2): 263-267, 1973.
    • (1973) J. Appl. Physiol. , vol.34 , Issue.2 , pp. 263-267
    • Gould, K.L.1    Trenholme, S.2    Kennedy, J.W.3
  • 4
    • 68349091504 scopus 로고    scopus 로고
    • Assessment of pulmonary vasculature and right heart by invasive haemodynamics and echocardiography
    • Hemnes, A. R., P. R. Forfia, and H. C. Champion. Assessment of pulmonary vasculature and right heart by invasive haemodynamics and echocardiography. Int. J. Clin. Pract. Suppl. 162: 4-19, 2009.
    • (2009) Int. J. Clin. Pract. Suppl. , vol.162 , pp. 4-19
    • Hemnes, A.R.1    Forfia, P.R.2    Champion, H.C.3
  • 5
    • 0018230640 scopus 로고
    • Percutaneous left ventricular catheterisation with an ultraminiature catheter-tip pressure transducer
    • Nichols, W. W., et al. Percutaneous left ventricular catheterisation with an ultraminiature catheter-tip pressure transducer. Cardiovasc. Res. 12(9): 566-568, 1978.
    • (1978) Cardiovasc. Res. , vol.12 , Issue.9 , pp. 566-568
    • Nichols, W.W.1
  • 6
    • 84860142442 scopus 로고    scopus 로고
    • Current practice for determining pulmonary capillary wedge pressure predisposes to serious errors in the classification of patients with pulmonary hypertension
    • Ryan, J. J., et al. Current practice for determining pulmonary capillary wedge pressure predisposes to serious errors in the classification of patients with pulmonary hypertension. Am. Heart J. 163(4): 589-594, 2012.
    • (2012) Am. Heart J. , vol.163 , Issue.4 , pp. 589-594
    • Ryan, J.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.