메뉴 건너뛰기




Volumn 61, Issue , 2013, Pages 8-20

Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort

Author keywords

Building energy efficiency; Control optimization; Daylighting; Electrochromic windows

Indexed keywords

BUILDING ENERGY EFFICIENCY; CONTROL OPTIMIZATION; ELECTROCHROMIC WINDOWS; ENERGY SAVINGS POTENTIAL; INTERIOR ILLUMINANCE; LEAST-SQUARES ALGORITHMS; LIGHTING SIMULATION; LINEAR INEQUALITY CONSTRAINTS;

EID: 84876946289     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2012.10.057     Document Type: Article
Times cited : (106)

References (33)
  • 1
    • 0041577553 scopus 로고
    • Window blinds as a potential energy saver-A case study
    • Department of Commerce, National Bureau of Standards Washington, DC, USA
    • A.I. Rubins, B.L. Collins, and R.L. Tibbott Window blinds as a potential energy saver-a case study NBS Building Science Series vol. 112 1978 Department of Commerce, National Bureau of Standards Washington, DC, USA
    • (1978) NBS Building Science Series , vol.112 VOL.
    • Rubins, A.I.1    Collins, B.L.2    Tibbott, R.L.3
  • 2
    • 33750339277 scopus 로고    scopus 로고
    • Monitored energy performance of electrochromic windows controlled for daylight and visual comfort
    • E.S. Lee, D.L. DiBartolomeo, J.H. Klems, M. Yazdanian, and S.E. Selkowitz Monitored energy performance of electrochromic windows controlled for daylight and visual comfort ASHRAE Transactions 112 2 2006 122 141
    • (2006) ASHRAE Transactions , vol.112 , Issue.2 , pp. 122-141
    • Lee, E.S.1    Dibartolomeo, D.L.2    Klems, J.H.3    Yazdanian, M.4    Selkowitz, S.E.5
  • 5
    • 84876910359 scopus 로고    scopus 로고
    • Control strategies and energy saving potentials for variable transmittance windows versus static windows
    • Copenhagen, Denmark June 19-22
    • J. Karlsson, B. Karlsson, and A. Roos Control strategies and energy saving potentials for variable transmittance windows versus static windows Eurosun 2000 Copenhagen, Denmark 2000 June 19-22
    • (2000) Eurosun 2000
    • Karlsson, J.1    Karlsson, B.2    Roos, A.3
  • 6
    • 2342661678 scopus 로고    scopus 로고
    • Control system and energy saving potential for switchable windows
    • Rio de Janeiro, Brazil August 13-15
    • J. Karlsson Control system and energy saving potential for switchable windows Building Simulation 2001 Rio de Janeiro, Brazil 2001 August 13-15
    • (2001) Building Simulation 2001
    • Karlsson, J.1
  • 7
    • 77954383992 scopus 로고    scopus 로고
    • Visual and energy performance of switchable windows with antireflection coatings
    • A. Jonsson, and A. Roos Visual and energy performance of switchable windows with antireflection coatings Solar Energy 84 2010 2010 1370 1375
    • (2010) Solar Energy , vol.84 , Issue.2010 , pp. 1370-1375
    • Jonsson, A.1    Roos, A.2
  • 8
    • 84876895368 scopus 로고    scopus 로고
    • Simulations of energy influence using different control mechanisms for electrochromic windows
    • Melbourne, Australia
    • A. Jonsson, and A. Roos Simulations of energy influence using different control mechanisms for electrochromic windows Sustainable Buildings 2008 Melbourne, Australia 2008
    • (2008) Sustainable Buildings 2008
    • Jonsson, A.1    Roos, A.2
  • 9
    • 72049117376 scopus 로고    scopus 로고
    • Evaluation of control strategies for different smart window combinations using computer simulations
    • A. Jonsson, and A. Roos Evaluation of control strategies for different smart window combinations using computer simulations Solar Energy 84 2010 2010 1 9
    • (2010) Solar Energy , vol.84 , Issue.2010 , pp. 1-9
    • Jonsson, A.1    Roos, A.2
  • 10
    • 84870204418 scopus 로고    scopus 로고
    • Switchable façade technology-energy efficient office buildings with smart facades
    • Göteborg, Sweden June 14-19
    • W.J. Platzer Switchable façade technology-energy efficient office buildings with smart facades Proceedings of the Solar World Congress 2003 Göteborg, Sweden 2003 June 14-19
    • (2003) Proceedings of the Solar World Congress 2003
    • Platzer, W.J.1
  • 13
    • 33947581281 scopus 로고    scopus 로고
    • Comparing the energy performance of an electrochromic window under various control strategies
    • M.N. Assimakopoulos, A. Tsangrassoulis, M. Santamouris, and G. Guarracino Comparing the energy performance of an electrochromic window under various control strategies Building and Environment 42 2007 2007 2829 2834
    • (2007) Building and Environment , vol.42 , Issue.2007 , pp. 2829-2834
    • Assimakopoulos, M.N.1    Tsangrassoulis, A.2    Santamouris, M.3    Guarracino, G.4
  • 14
    • 0037332921 scopus 로고    scopus 로고
    • Visual and energy management of electrochromic windows in Mediterranean climate
    • F. Gugliermetti, and P. Bisegna Visual and energy management of electrochromic windows in Mediterranean climate Building and Environment 38 2003 2003 479 492
    • (2003) Building and Environment , vol.38 , Issue.2003 , pp. 479-492
    • Gugliermetti, F.1    Bisegna, P.2
  • 15
    • 0020002663 scopus 로고
    • Glare from windows: Current views of the problem
    • P. Chauvel Glare from windows: current views of the problem Lighting Research and Technology 14 1 1982 31 46
    • (1982) Lighting Research and Technology , vol.14 , Issue.1 , pp. 31-46
    • Chauvel, P.1
  • 17
    • 0035451348 scopus 로고    scopus 로고
    • Dynamic Radiance-based daylight simulations for a full-scale test office with outer Venetian blinds
    • C.F. Reinhart, and O. Walkenhorst Dynamic Radiance-based daylight simulations for a full-scale test office with outer Venetian blinds Energy & Buildings 33 7 2001 683 697
    • (2001) Energy & Buildings , vol.33 , Issue.7 , pp. 683-697
    • Reinhart, C.F.1    Walkenhorst, O.2
  • 19
    • 84869815526 scopus 로고    scopus 로고
    • Illuminating Engineering Society of North America ninth ed. IESNA New York
    • Illuminating Engineering Society of North America The IESNA Lighting Handbook: Reference and Application ninth ed. 1999 IESNA New York
    • (1999) The IESNA Lighting Handbook: Reference and Application
  • 20
    • 84876922599 scopus 로고    scopus 로고
    • Discomfort glare from large area glare sources at computer workstations, building with daylight: Energy efficient design
    • Houston, Texas, USA pp. 1825-1829
    • W.K.E. Osterhaus Discomfort glare from large area glare sources at computer workstations, building with daylight: energy efficient design Proceedings 1996 IEEE Industry Applications Society annual Meeting, II Houston, Texas, USA 1996 pp. 1825-1829
    • (1996) Proceedings 1996 IEEE Industry Applications Society Annual Meeting, II
    • Osterhaus, W.K.E.1
  • 22
    • 78149281333 scopus 로고    scopus 로고
    • Windows, view, and office characteristics predict physical and psychological discomfort
    • M.B.C. Aries, J.A. Veitch, and G.R. Newsham Windows, view, and office characteristics predict physical and psychological discomfort Journal of Environmental Psychology 30 2010 533 541
    • (2010) Journal of Environmental Psychology , vol.30 , pp. 533-541
    • Aries, M.B.C.1    Veitch, J.A.2    Newsham, G.R.3
  • 23
    • 34248575779 scopus 로고    scopus 로고
    • The influence of forest view through a window on job satisfaction and job stress
    • W.S. Shin The influence of forest view through a window on job satisfaction and job stress Scandinavian Journal of Forest Research 22 2007 248 253
    • (2007) Scandinavian Journal of Forest Research , vol.22 , pp. 248-253
    • Shin, W.S.1
  • 24
    • 0022920173 scopus 로고
    • Human responses to vegetation and landscapes
    • R.S. Ulrich Human responses to vegetation and landscapes Landscape and Urban Planning 13 1986 29 44
    • (1986) Landscape and Urban Planning , vol.13 , pp. 29-44
    • Ulrich, R.S.1
  • 25
    • 0021249997 scopus 로고
    • View through a window may influence recovery from surgery
    • R.S. Ulrich View through a window may influence recovery from surgery Science 224 1984 420 421
    • (1984) Science , vol.224 , pp. 420-421
    • Ulrich, R.S.1
  • 26
    • 0018825340 scopus 로고
    • Windows in the intensive therapy unit
    • P. Keep, J. James, and M. Inman Windows in the intensive therapy unit Anaesthesia 35 1980 257 262
    • (1980) Anaesthesia , vol.35 , pp. 257-262
    • Keep, P.1    James, J.2    Inman, M.3
  • 27
    • 84856066190 scopus 로고    scopus 로고
    • Health benefits of a view of nature through the window: A quasi-experimental study of patients in a residential rehabilitation center
    • R.K. Raanaas, G.G. Patil, and T. Hartig Health benefits of a view of nature through the window: a quasi-experimental study of patients in a residential rehabilitation center Clinical Rehabilitation 26 1 2011 21 32
    • (2011) Clinical Rehabilitation , vol.26 , Issue.1 , pp. 21-32
    • Raanaas, R.K.1    Patil, G.G.2    Hartig, T.3
  • 29
    • 33646371498 scopus 로고    scopus 로고
    • Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: A literature review
    • A.D. Galasiu, and J.A. Veitch Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review Energy and Buildings 38 7 2006 728 742
    • (2006) Energy and Buildings , vol.38 , Issue.7 , pp. 728-742
    • Galasiu, A.D.1    Veitch, J.A.2
  • 32
    • 2542488295 scopus 로고    scopus 로고
    • Lightswitch-2002: A model for manual and automated control of electric lighting and blinds
    • C.F. Reinhart Lightswitch-2002: a model for manual and automated control of electric lighting and blinds Solar Energy 77 1 2004 15 28
    • (2004) Solar Energy , vol.77 , Issue.1 , pp. 15-28
    • Reinhart, C.F.1
  • 33
    • 0027568526 scopus 로고
    • All-weather model for sky luminance distributions-preliminary configuration and validation
    • R. Perez, R. Seals, and J. Michalsky All-weather model for sky luminance distributions-preliminary configuration and validation Solar Energy 50 3 1993 235 245
    • (1993) Solar Energy , vol.50 , Issue.3 , pp. 235-245
    • Perez, R.1    Seals, R.2    Michalsky, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.