Volumn , Issue , 2003, Pages 413-419

Determining harmonic characteristics of typical single phase nonlinear loads

Author keywords

[No Author keywords available]

Indexed keywords

BALLASTS (LAMP); HARMONIC DISTORTION; OFFICE BUILDINGS; PERSONAL COMPUTERS;

EID: 84876885666     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SCORED.2003.1459733     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 1
    • 0037662902 scopus 로고    scopus 로고
    • Parameters affecting harmonic propagation and distortion levels in non-linear distribution system
    • E.F. El-Saadany, " Parameters Affecting Harmonic Propagation and Distortion Levels in Non-Linear Distribution System. Power Engineering Socicty Summer Meeting, Vol.2, pp.1010 -1016, 2002.
    • (2002) Power Engineering Socicty Summer Meeting , vol.2 , pp. 1010-1016
    • El-Saadany, E.F.1
  • 4
    • 0033326864 scopus 로고    scopus 로고
    • Typical industrial lv system fo: Harmonic propagation study under balanced and unbalanced conditions using pspice models
    • Zhu Jun, A. I. Maswood, " Typical Industrial LV System fo: Harmonic Propagation Study Under Balanced and Unbalanced Conditions Using Pspice Models", Proceedings of IEEE 1999 lnt'1 Power Engineering Conference, Vol.2, pp.1147-1152 1999.
    • (1999) Proceedings of IEEE 1999 Lnt'1 Power Engineering Conference , vol.2 , pp. 1147-1152
    • Zhu, J.1    Maswood, A.I.2
  • 7
    • 84883644795 scopus 로고    scopus 로고
    • Analysis of 'Compensation factors influencing the net harmonic current produced by single-phase non-linear loads
    • Jointly Organized by IEEE/PES Ond NTUA, Athens, Greece Octobcr
    • A.Mansoor and W.M Grady. "Analysis of ' Compensation Factors Influencing the Net harmonic Current Produced by Single-Phase Non- Linear Loads", 8th Int'l Conference on Harmonics and Quality of Power lCHQP'98. jointly organized by IEEE/PES ond NTUA, Athens, Greece pp. 883- 889, Octobcr 1998.
    • (1998) 8th Int'l Conference on Harmonics and Quality of Power LCHQP'98 , pp. 883-889
    • Mansoor, A.1    Grady, W.M.2
  • 8
    • 0036085447 scopus 로고    scopus 로고
    • Estimating the net harmonic currents produced hy selected distributed single-phase loads: Computers, television and incandescent light dimmers
    • W. M. Grady, A. Mansoor, E.F Fuchs, P.Verde and M. Doyle, "Estimating the Net Harmonic Currents Produced hy Selected Distributed Single-Phase Loads: Computers, Television and incandescent Light Dimmers", IEEE Power Engineering Society Winter Meeting, Vol.2, pp. 1090-1094. 2002.
    • (2002) IEEE Power Engineering Society Winter Meeting , vol.2 , pp. 1090-1094
    • Grady, W.M.1    Mansoor, A.2    Fuchs, E.F.3    Verde, P.4    Doyle, M.5
  • 10
    • 0031623657 scopus 로고    scopus 로고
    • UA pspice model for the electrical characteristics of fluorescent lamps
    • May
    • T.Liu, K.J.Tseng and DM Viladigamuwa UA Pspice Model for the Electrical Characteristics ofFluorescent Lamps" 29' IEEE PESC, pp.1749- 1754, May 1998.
    • (1998) 29'IEEE PESC , pp. 1749-1754
    • Liu, T.1    Tseng, K.J.2    Viladigamuwa, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.