-
1
-
-
0032547931
-
Implantable left ventricular assist devices
-
Goldstein DJ, Oz MC, Rose EA. Implantable left ventricular assist devices. N Engl J Med 1998;339:1522-33.
-
(1998)
N Engl J Med
, vol.339
, pp. 1522-1533
-
-
Goldstein, D.J.1
Oz, M.C.2
Rose, E.A.3
-
2
-
-
27744462363
-
Right ventricular failure after left ventricular assist device implantation: the need for an implantable right ventricular assist device
-
Furukawa K, Motomura T, Nosé Y. Right ventricular failure after left ventricular assist device implantation: the need for an implantable right ventricular assist device. Artif Organs 2005;29:369-77.
-
(2005)
Artif Organs
, vol.29
, pp. 369-377
-
-
Furukawa, K.1
Motomura, T.2
Nosé, Y.3
-
3
-
-
1442275669
-
Is severe right ventricular failure in left ventricular assist device recipients a risk factor for unsuccessful bridging to transplant and post-transplant mortality
-
Morgan JA, John R, Lee BJ, Oz MC, Naka Y. Is severe right ventricular failure in left ventricular assist device recipients a risk factor for unsuccessful bridging to transplant and post-transplant mortality? Ann Thorac Surg 2004;77:859-63.
-
(2004)
Ann Thorac Surg
, vol.77
, pp. 859-863
-
-
Morgan, J.A.1
John, R.2
Lee, B.J.3
Oz, M.C.4
Naka, Y.5
-
4
-
-
33746717534
-
Right ventricular failure after left ventricular assist device insertion: preoperative risk factors
-
Santambrogio L, Bianchi T, Fuardo M, Gazzoli F, Veronesi R, Braschi A et al. Right ventricular failure after left ventricular assist device insertion: preoperative risk factors. Interact CardioVasc Thorac Surg 2006;5:379-82.
-
(2006)
Interact CardioVasc Thorac Surg
, vol.5
, pp. 379-382
-
-
Santambrogio, L.1
Bianchi, T.2
Fuardo, M.3
Gazzoli, F.4
Veronesi, R.5
Braschi, A.6
-
5
-
-
0037167691
-
Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients
-
Ochiai Y, McCarthy PM, Smedira NG, Banbury MK, Navia JL, Feng J et al. Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients. Circulation 2002; 106:I-198-202.
-
(2002)
Circulation
, vol.106
, pp. 198-202
-
-
Ochiai, Y.1
McCarthy, P.M.2
Smedira, N.G.3
Banbury, M.K.4
Navia, J.L.5
Feng, J.6
-
6
-
-
44049094013
-
The right ventricular failure risk score a preoperative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates
-
Matthews J, Koelling T, Pagani F, Aaronson K. The right ventricular failure risk score a preoperative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol 2008; 51:2163-72.
-
(2008)
J Am Coll Cardiol
, vol.51
, pp. 2163-2172
-
-
Matthews, J.1
Koelling, T.2
Pagani, F.3
Aaronson, K.4
-
7
-
-
57049174043
-
Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support
-
Fitzpatrick JR III, Frederick JR, Hsu VM, Kozin ED, O'Hara ML, Howell E et al. Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support. J Heart Lung Transplant 2008;27:1286-92.
-
(2008)
J Heart Lung Transplant
, vol.27
, pp. 1286-1292
-
-
Fitzpatrick III, J.R.1
Frederick, J.R.2
Hsu, V.M.3
Kozin, E.D.4
O'Hara, M.L.5
Howell, E.6
-
8
-
-
57049100424
-
Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device
-
Potapov EV, Stepanenko A, Dandel M, Kukucka M, Lehmkuhl HB, Weng Y et al. Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device. J Heart Lung Transplant 2008;27:1275-81.
-
(2008)
J Heart Lung Transplant
, vol.27
, pp. 1275-1281
-
-
Potapov, E.V.1
Stepanenko, A.2
Dandel, M.3
Kukucka, M.4
Lehmkuhl, H.B.5
Weng, Y.6
-
9
-
-
0032419214
-
Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children
-
Hetzer R, Loebe M, Potapov EV, Weng Y, Stiller B, Hennig E et al. Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children. Ann Thorac Surg 1998;66:1498-506.
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 1498-1506
-
-
Hetzer, R.1
Loebe, M.2
Potapov, E.V.3
Weng, Y.4
Stiller, B.5
Hennig, E.6
-
10
-
-
34147184289
-
Ventricular assist devices in children: current achievements and future perspectives
-
Potapov EV, Stiller B, Hetzer R. Ventricular assist devices in children: current achievements and future perspectives. Pediatr Transplant 2007; 11:241-55.
-
(2007)
Pediatr Transplant
, vol.11
, pp. 241-255
-
-
Potapov, E.V.1
Stiller, B.2
Hetzer, R.3
-
11
-
-
79960563307
-
Mechanical circulatory support-results, developments and trends
-
Krabatsch T, Schweiger M, Stepanenko A, Kukucka M, Vierecke J, Lehmkuhl HB et al. Mechanical circulatory support-results, developments and trends. J Cardiovasc Transl Res 2011;4:332-9.
-
(2011)
J Cardiovasc Transl Res
, vol.4
, pp. 332-339
-
-
Krabatsch, T.1
Schweiger, M.2
Stepanenko, A.3
Kukucka, M.4
Vierecke, J.5
Lehmkuhl, H.B.6
-
12
-
-
0034078975
-
Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe
-
Kampmann C, Wiethoff CM, Wenzel A, Stolz G, Betancor M, Wippermann CF et al. Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe. Heart 2000;83:667-72.
-
(2000)
Heart
, vol.83
, pp. 667-672
-
-
Kampmann, C.1
Wiethoff, C.M.2
Wenzel, A.3
Stolz, G.4
Betancor, M.5
Wippermann, C.F.6
-
13
-
-
79151483080
-
Systolic right ventricular function in preterm and term neonates: reference values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 patients and calculation of Z-score values
-
Koestenberger M, Nagel B, Ravekes W, Urlesberger B, Raith W, Avian A et al. Systolic right ventricular function in preterm and term neonates: reference values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 patients and calculation of Z-score values. Neonatology 2011;100:85-92.
-
(2011)
Neonatology
, vol.100
, pp. 85-92
-
-
Koestenberger, M.1
Nagel, B.2
Ravekes, W.3
Urlesberger, B.4
Raith, W.5
Avian, A.6
-
14
-
-
66549117149
-
Right ventricular function in infants, children and adolescents: reference values of the tricuspid annular plane systolic excursion (TAPSE) in 640 healthy patients and calculation of z score values
-
Koestenberger M, Ravekes W, Everett AD, Stueger HP, Heinzl B, Gamillscheg A et al. Right ventricular function in infants, children and adolescents: reference values of the tricuspid annular plane systolic excursion (TAPSE) in 640 healthy patients and calculation of z score values. J Am Soc Echocardiogr 2009;22:715-9.
-
(2009)
J Am Soc Echocardiogr
, vol.22
, pp. 715-719
-
-
Koestenberger, M.1
Ravekes, W.2
Everett, A.D.3
Stueger, H.P.4
Heinzl, B.5
Gamillscheg, A.6
-
15
-
-
0025782852
-
Analysis and predictors of pulmonary vascular resistance after cardiac transplantation
-
Bourge RC, Kirklin JK, Naftel DC, White C, Mason DA, Epstein AE. Analysis and predictors of pulmonary vascular resistance after cardiac transplantation. J Thorac Cardiovasc Surg 1991;101:432-45.
-
(1991)
J Thorac Cardiovasc Surg
, vol.101
, pp. 432-445
-
-
Bourge, R.C.1
Kirklin, J.K.2
Naftel, D.C.3
White, C.4
Mason, D.A.5
Epstein, A.E.6
-
16
-
-
0026185490
-
Importance of ventricular arrhythmias in bridge patients with ventricular assist devices
-
Aria H, Schwartz MT, Pennington DG. Importance of ventricular arrhythmias in bridge patients with ventricular assist devices. ASAIO J 1991;37: M427-8.
-
(1991)
ASAIO J
, vol.37
-
-
Aria, H.1
Schwartz, M.T.2
Pennington, D.G.3
-
17
-
-
0026183864
-
A model of right ventricular failure after global myocardial ischemia and mechanical left ventricular support
-
Shuman TA, Palazzo RS, Jaquiss RBD, Harper BD, Barzilai B, Cox JL et al. A model of right ventricular failure after global myocardial ischemia and mechanical left ventricular support. ASAIO J 1991;37: M212-3.
-
(1991)
ASAIO J
, vol.37
-
-
Shuman, T.A.1
Palazzo, R.S.2
Jaquiss, R.B.D.3
Harper, B.D.4
Barzilai, B.5
Cox, J.L.6
-
19
-
-
33744987129
-
Pediatric Heart Transplant Study Investigators Outcomes of children bridged to heart transplantation with ventricular assist devices: a multiinstitutional study
-
Blume ED, Naftel DC, Bastardi HJ, Duncan BW, Kirklin JK, Webber SA, Pediatric Heart Transplant Study Investigators. Outcomes of children bridged to heart transplantation with ventricular assist devices: a multiinstitutional study. Circulation 2006;113:2313-9.
-
(2006)
Circulation
, vol.113
, pp. 2313-2319
-
-
Blume, E.D.1
Naftel, D.C.2
Bastardi, H.J.3
Duncan, B.W.4
Kirklin, J.K.5
Webber, S.A.6
-
20
-
-
0035069119
-
Multicenter experience with the Thoratec ventricular assist device in children and adolescents
-
Reinhartz O, Keith FM, El-Banayosy A, McBride LR, Robbins RC, Copeland JG et al. Multicenter experience with the Thoratec ventricular assist device in children and adolescents. J Heart Lung Transplant 2001; 20:439-48.
-
(2001)
J Heart Lung Transplant
, vol.20
, pp. 439-448
-
-
Reinhartz, O.1
Keith, F.M.2
El-Banayosy, A.3
McBride, L.R.4
Robbins, R.C.5
Copeland, J.G.6
-
21
-
-
0029763775
-
Inhibition of vasoconstriction by phosphodiesterase III inhibitor milrinone in human conduit arteries used as coronary bypass grafts
-
He GW, Yang CQ. Inhibition of vasoconstriction by phosphodiesterase III inhibitor milrinone in human conduit arteries used as coronary bypass grafts. J Cardiovasc Pharmacol 1996;28:208-14.
-
(1996)
J Cardiovasc Pharmacol
, vol.28
, pp. 208-214
-
-
He, G.W.1
Yang, C.Q.2
-
22
-
-
0022001187
-
Positive inotropic and vasodilator actions of milrinone in patients with severe congestive heart failure: dose-response relationships and comparison to nitroprusside
-
Jaski BE, Fifer MA, Wright RF, Braunwald E, Colucci WS. Positive inotropic and vasodilator actions of milrinone in patients with severe congestive heart failure: dose-response relationships and comparison to nitroprusside. J Clin Invest 1985;75:643-9.
-
(1985)
J Clin Invest
, vol.75
, pp. 643-649
-
-
Jaski, B.E.1
Fifer, M.A.2
Wright, R.F.3
Braunwald, E.4
Colucci, W.S.5
-
23
-
-
0023404509
-
Circulatory and respiratory effects of infused adenosine in conscious man
-
Fuller RW, Maxwell DL, Conradson TB, Dixon CM, Barnes PJ. Circulatory and respiratory effects of infused adenosine in conscious man. Br J Clin Pharmacol 1987;24:306-17.
-
(1987)
Br J Clin Pharmacol
, vol.24
, pp. 306-317
-
-
Fuller, R.W.1
Maxwell, D.L.2
Conradson, T.B.3
Dixon, C.M.4
Barnes, P.J.5
-
24
-
-
0036156179
-
Effects of milrinone for right ventricular failure after left ventricular assist device implantation
-
Kihara S, Kawai A, Fukuda T, Yamamoto N, Aomi S, Nishida H et al. Effects of milrinone for right ventricular failure after left ventricular assist device implantation. Heart Vessels 2002;16:69-71.
-
(2002)
Heart Vessels
, vol.16
, pp. 69-71
-
-
Kihara, S.1
Kawai, A.2
Fukuda, T.3
Yamamoto, N.4
Aomi, S.5
Nishida, H.6
-
25
-
-
0032542897
-
What's wrong with Bonferroni adjustments
-
Perneger TV. What's wrong with Bonferroni adjustments. BMJ 1998;316: 1236-8.
-
(1998)
BMJ
, vol.316
, pp. 1236-1238
-
-
Perneger, T.V.1
|