메뉴 건너뛰기




Volumn 78, Issue 6, 2013, Pages 825-830

Volume interpolated 3D-spoiled gradient echo sequence is better than dynamic contrast spin echo sequence for MRI detection of corticotropin secreting pituitary microadenomas

Author keywords

[No Author keywords available]

Indexed keywords

CORTICOTROPIN; CORTICOTROPIN RELEASING FACTOR;

EID: 84876558057     PISSN: 03000664     EISSN: 13652265     Source Type: Journal    
DOI: 10.1111/cen.12069     Document Type: Article
Times cited : (50)

References (18)
  • 2
    • 84887262337 scopus 로고    scopus 로고
    • A change in pituitary magnetic resonance imaging protocol detects ACTH secreting tumours in patient with previously negative results
    • Chaudhry, I.N., Sinai, N., Oldfeild, E.H., et al,. (2010) A change in pituitary magnetic resonance imaging protocol detects ACTH secreting tumours in patient with previously negative results. Clinical Endocrinology, 75, 673-677.
    • (2010) Clinical Endocrinology , vol.75 , pp. 673-677
    • Chaudhry, I.N.1    Sinai, N.2    Oldfeild, E.H.3
  • 3
    • 0028075861 scopus 로고
    • Raymond's syndrome following petrosal sinus sampling
    • Seyer, H., Honegger, J., Schott, W., et al,. (1994) Raymond's syndrome following petrosal sinus sampling. Acta Neurochirurgica (Wien), 131, 157-159.
    • (1994) Acta Neurochirurgica (Wien) , vol.131 , pp. 157-159
    • Seyer, H.1    Honegger, J.2    Schott, W.3
  • 4
    • 0030922167 scopus 로고    scopus 로고
    • A neurological complication of inferior petrosal sinus sampling during investigation for Cushing's disease: A case report
    • Sturrock, N.D., &, Jeffcoate, W.J., (1997) A neurological complication of inferior petrosal sinus sampling during investigation for Cushing's disease: a case report. The Journal of Neurology, Neurosurgery, and Psychiatry, 62, 527-528.
    • (1997) The Journal of Neurology, Neurosurgery, and Psychiatry , vol.62 , pp. 527-528
    • Sturrock, N.D.1    Jeffcoate, W.J.2
  • 5
    • 0026784682 scopus 로고
    • Neurologic complications of petrosal sinus sampling
    • Miller, D.L., Doppman, J.L., Peterman, S.B., et al,. (1992) Neurologic complications of petrosal sinus sampling. Radiology, 185, 143-147.
    • (1992) Radiology , vol.185 , pp. 143-147
    • Miller, D.L.1    Doppman, J.L.2    Peterman, S.B.3
  • 7
    • 0031041782 scopus 로고    scopus 로고
    • Magnetic resonance imaging in Cushing disease. Prediction of surgical results
    • Barrou, Z., Abecassis, J.P., Guilhaume, B., et al,. (1997) Magnetic resonance imaging in Cushing disease. Prediction of surgical results. La Presse Medicale (Paris), 26, 7-11.
    • (1997) La Presse Medicale (Paris) , vol.26 , pp. 7-11
    • Barrou, Z.1    Abecassis, J.P.2    Guilhaume, B.3
  • 8
    • 0028846628 scopus 로고
    • Factors influencing the immediate and late outcome of Cushing's disease treated by trans sphenoidal surgery: A retrospective study by the European Cushing's Disease Survey Group
    • Bochicchio, D., Losa, M., Buchfelder, M., et al,. (1995) Factors influencing the immediate and late outcome of Cushing's disease treated by trans sphenoidal surgery: a retrospective study by the European Cushing's Disease Survey Group. Journal of Clinical Endocrinology and Metabolism, 80, 3114-3120.
    • (1995) Journal of Clinical Endocrinology and Metabolism , vol.80 , pp. 3114-3120
    • Bochicchio, D.1    Losa, M.2    Buchfelder, M.3
  • 9
    • 15144348469 scopus 로고    scopus 로고
    • Comparative evaluation of conventional and dynamic magnetic resonance imaging of the pituitary gland for the diagnosis of Cushing's disease
    • Tabarin, A., Laurent, F., Catargi, B., et al,. (1998) Comparative evaluation of conventional and dynamic magnetic resonance imaging of the pituitary gland for the diagnosis of Cushing's disease. Clinical Endocrinology, 49, 293-300.
    • (1998) Clinical Endocrinology , vol.49 , pp. 293-300
    • Tabarin, A.1    Laurent, F.2    Catargi, B.3
  • 10
    • 0038360756 scopus 로고    scopus 로고
    • Spoiled gradient recalled acquisition in the steady state technique is superior to conventional post contrast spin echo technique for magnetic resonance imaging detection of adrenocorticotropin-secreting pituitary tumors
    • Patronas, N., Bulakbasi, N., Stratakis, C.A., et al,. (2003) Spoiled gradient recalled acquisition in the steady state technique is superior to conventional post contrast spin echo technique for magnetic resonance imaging detection of adrenocorticotropin-secreting pituitary tumors. Journal of Clinical Endocrinology & Metabolism, 88, 1565-156.
    • (2003) Journal of Clinical Endocrinology & Metabolism , vol.88 , pp. 1565-1156
    • Patronas, N.1    Bulakbasi, N.2    Stratakis, C.A.3
  • 11
    • 24344478749 scopus 로고    scopus 로고
    • Detection of ACTH secreting pituitary adenomas by magnetic resonance imaging in children and adolescents with Cushing's disease
    • Batista, D., Courkoutsakis, N.A., Oldfeild, E.H., et al,. (2005) Detection of ACTH secreting pituitary adenomas by magnetic resonance imaging in children and adolescents with Cushing's disease. Journal of Clinical Endocrinology & Metabolism, 90, 5134-5140.
    • (2005) Journal of Clinical Endocrinology & Metabolism , vol.90 , pp. 5134-5140
    • Batista, D.1    Courkoutsakis, N.A.2    Oldfeild, E.H.3
  • 12
    • 0025281774 scopus 로고
    • Pituitary microadenomas: Diagnosis with two- and three-dimensional MR imaging at 1.5 T before and after injection of gadolinium
    • Stadnik, T., Stevenaert, A., Beckers, A., et al,. (1990) Pituitary microadenomas: diagnosis with two- and three-dimensional MR imaging at 1.5 T before and after injection of gadolinium. Radiology, 176, 419-428.
    • (1990) Radiology , vol.176 , pp. 419-428
    • Stadnik, T.1    Stevenaert, A.2    Beckers, A.3
  • 13
    • 0028339709 scopus 로고
    • 3D-FT thin sections MRI of prolactin secreting pituitary microadenomas
    • Girard, N., Brue, T., Chabert-Orsini, V., et al,. (1994) 3D-FT thin sections MRI of prolactin secreting pituitary microadenomas. Neuroradiology, 36, 376-379.
    • (1994) Neuroradiology , vol.36 , pp. 376-379
    • Girard, N.1    Brue, T.2    Chabert-Orsini, V.3
  • 14
    • 0029126381 scopus 로고
    • MR imaging of the brain: Comparison of gradient-echo and spin-echo pulse sequences
    • Pui, M.H., Fok, E.C., (1995) MR imaging of the brain: comparison of gradient-echo and spin-echo pulse sequences. American Journal of Roentgenology, 165, 959-962.
    • (1995) American Journal of Roentgenology , vol.165 , pp. 959-962
    • Pui, M.H.1    Fok, E.C.2
  • 15
    • 34347207557 scopus 로고    scopus 로고
    • Dynamic pituitary MRI has high sensitivity and specificity for the diagnosis of mild Cushing's syndrome and should be part of the initial workup
    • Friedman, T.C., Zuckerbraun, E., Lee, M.L., et al,. (2007) Dynamic pituitary MRI has high sensitivity and specificity for the diagnosis of mild Cushing's syndrome and should be part of the initial workup. Hormone and Metabolic Research, 39, 451-456.
    • (2007) Hormone and Metabolic Research , vol.39 , pp. 451-456
    • Friedman, T.C.1    Zuckerbraun, E.2    Lee, M.L.3
  • 16
    • 11144336660 scopus 로고    scopus 로고
    • Contrast-enhanced volumetric interpolated breath-hold examination compared with spin-echo T1-weighted imaging of head and neck tumors
    • Kataoka, M., Ueda, H., Koyama, T., et al,. (2005) Contrast-enhanced volumetric interpolated breath-hold examination compared with spin-echo T1-weighted imaging of head and neck tumors. American Journal of Roentgenology, 184, 313-319.
    • (2005) American Journal of Roentgenology , vol.184 , pp. 313-319
    • Kataoka, M.1    Ueda, H.2    Koyama, T.3
  • 18
    • 0032882776 scopus 로고    scopus 로고
    • Abdominal MR imaging with a volumetric interpolated breath-hold examination
    • Rofsky, N.M., Lee, V.S., Laub, G., et al,. (1999) Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology, 212, 876-884.
    • (1999) Radiology , vol.212 , pp. 876-884
    • Rofsky, N.M.1    Lee, V.S.2    Laub, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.