-
1
-
-
0030910516
-
Incidence and complications of abrasion of implantable cardioverter-defibrillator leads
-
De Lugio DB, Sathavorn C, Mera F, Leon A, Walter PF, Langberg JJ. Incidence and complications of abrasion of implantable cardioverter-defibrillator leads. Am J Cardiol 1997;79:1409-11.
-
(1997)
Am J Cardiol
, vol.79
, pp. 1409-1411
-
-
De Lugio, D.B.1
Sathavorn, C.2
Mera, F.3
Leon, A.4
Walter, P.F.5
Langberg, J.J.6
-
2
-
-
0031719076
-
Late complications in patients with pectoral defibrillator implants with transvenous defibrillator lead systems: High incidence of insulation breakdown
-
Mehta D, Nayak HM, Singson M, Chao S, Pe E, Camunas JL et al. Late complications in patients with pectoral defibrillator implants with transvenous defibrillator lead systems: High incidence of insulation breakdown. Pacing Clin Electrophysiol 1998;21:1893-900.
-
(1998)
Pacing Clin Electrophysiol
, vol.21
, pp. 1893-1900
-
-
Mehta, D.1
Nayak, H.M.2
Singson, M.3
Chao, S.4
Pe, E.5
Camunas, J.L.6
-
4
-
-
34248579318
-
Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of .10 years
-
Kleeman T, Becker T, Doenges K, Vater M, Senges J, Schneider S et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of .10 years. Circulation 115:2474-80.
-
Circulation
, vol.115
, pp. 2474-2480
-
-
Kleeman, T.1
Becker, T.2
Doenges, K.3
Vater, M.4
Senges, J.5
Schneider, S.6
-
5
-
-
70349504339
-
A new insulation material for cardiac leads with potential for improved performance
-
(May
-
Jenney C, Tan J, Karicherla A, Burke J, Helland J. A new insulation material for cardiac leads with potential for improved performance. Heart Rhythm 2005; 2(May Supplement):S318.
-
(2005)
Heart Rhythm
, vol.2
, pp. S318
-
-
Jenney, C.1
Tan, J.2
Karicherla, A.3
Burke, J.4
Helland, J.5
-
6
-
-
85045205840
-
-
(20 April 2012, date last accessed
-
Durata lead reliability, St Jude Medical 2011. http://www.google.de/search? client=safari&rls=en&q=optim+lead+insulation+fda&ie=UTF-8&oe=UTF-8&redir-esc=&ei=9emQT9ndA4fU4QS01rzDBA (20 April 2012, date last accessed.
-
(2011)
Durata Lead Reliability, St Jude Medical
-
-
-
7
-
-
84864423015
-
Deaths caused by the failure of riata and riata st implantable cardioverter-defibrillator leads
-
Hauser RG, Abdelhadi R, McGriff D, Kallinen Retel L. Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Heart Rhythm 2012;9:1227-35.
-
(2012)
Heart Rhythm
, vol.9
, pp. 1227-1235
-
-
Hauser, R.G.1
Abdelhadi, R.2
McGriff, D.3
Kallinen Retel, L.4
-
8
-
-
85045210889
-
-
Sylmar CA: St Jude Medical, Inc. 24 April 2012, date last accessed
-
Tsung p. Cardiac Rhythm Management Product Performance Report November 2011. Sylmar CA: St Jude Medical, Inc. www.sjmprofessional.com/Resources/product-performance-reports/Product-Performance-Report.aspx (24 April 2012, date last accessed).
-
Tsung P. Cardiac Rhythm Management Product Performance Report November 2011
-
-
-
9
-
-
85045212395
-
-
Sylmar CA St Jude Medical Inc. 24 April 2012, date last accessed
-
Durata Lead Reliability. Sylmar CA: St Jude Medical Inc. www.sjmprofessional. com/Cardiac%20Pro/Resources/presentations/durata-reliability.aspx (24 April 2012, date last accessed).
-
Durata Lead Reliability
-
-
-
10
-
-
84857850566
-
Icd leads and postmarketing surveillance
-
Carlson MD. ICD leads and postmarketing surveillance. N Engl J Med 2012;366:967.
-
(2012)
N Engl J Med
, vol.366
, pp. 967
-
-
Carlson, M.D.1
-
11
-
-
84859939804
-
Riata implantable cardioverterdefibrillator failure: Analysis of explanted leads with a unique insulation defect
-
Hauser RG, McGriff D, Kallinen Retel M. Riata implantable cardioverterdefibrillator failure: Analysis of explanted leads with a unique insulation defect. Heart Rhythm 2012;9:742-9.
-
(2012)
Heart Rhythm
, vol.9
, pp. 742-749
-
-
Hauser, R.G.1
McGriff, D.2
Kallinen Retel, M.3
-
12
-
-
1942436763
-
Longterm in vivo biostability of poly(dimethylsiloxane) poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers
-
Simmons A, Hyvarinen J, Odell RA, Martin DJ, Gunatillake PA, Noble KR et al. Longterm in vivo biostability of poly(dimethylsiloxane) poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers. Biomaterials 2004;25:4887-900.
-
(2004)
Biomaterials
, vol.25
, pp. 4887-4900
-
-
Simmons, A.1
Hyvarinen, J.2
Odell, R.A.3
Martin, D.J.4
Gunatillake, P.A.5
Noble, K.R.6
-
13
-
-
84969296408
-
Comparative in vivo biostability study of a new lead insulation material versus polyurethanes
-
(May
-
Tan J, Jenney C. Comparative in vivo biostability study of a new lead insulation material versus polyurethanes. Heart Rhythm 2006;3(May Supplement):S146.
-
(2006)
Heart Rhythm
, vol.3
, pp. S146
-
-
Tan, J.1
Jenney, C.2
-
14
-
-
58849112108
-
Performance of the st jude medical leads
-
Epstein AE, Baker JH, Beau SL, Deering TF, Greenberg SM, Goldman DS. Performance of the St. Jude Medical leads. Heart Rhythm 2009;6:204-9.
-
(2009)
Heart Rhythm
, vol.6
, pp. 204-209
-
-
Epstein, A.E.1
Baker, J.H.2
Beau, S.L.3
Deering, T.F.4
Greenberg, S.M.5
Goldman, D.S.6
-
15
-
-
84884600026
-
Decreased incidence of lead abrasion with optim insulation
-
(1 August 2012, date last accessed
-
Wilkoff B, Freedman R, Hayes D, Kalbfleisch S, Kutalek S, Schaerf R. Decreased incidence of lead abrasion with Optim insulation. Europace 2011;13(Suppl 3) doi:10.1093/europace/eur220. Available at http://europace.oxfordjournals.org/content/13/suppl-3/NP.10.abstract (1 August 2012, date last accessed).
-
(2011)
Europace
, vol.13
-
-
Wilkoff, B.1
Freedman, R.2
Hayes, D.3
Kalbfleisch, S.4
Kutalek, S.5
Schaerf, R.6
|