메뉴 건너뛰기




Volumn 58, Issue 1, 2013, Pages 35-38

Novel electrode configuration for highly linear impedance pneumography

Author keywords

functional residual capacity; lung function testing; lung volume; thoracic electrical impedance; tidal breathing

Indexed keywords

ELECTRICAL IMPEDANCE; FUNCTIONAL RESIDUAL CAPACITIES; LUNG FUNCTION TESTING; LUNG VOLUME; TIDAL BREATHING;

EID: 84876537703     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/bmt-2012-0068     Document Type: Article
Times cited : (58)

References (18)
  • 1
    • 8544229058 scopus 로고
    • The measurement of respiratory volumes in animals and man with use of electrical impedance
    • Baker LE, Geddes LA. The measurement of respiratory volumes in animals and man with use of electrical impedance. Ann NY Acad Sci 1970; 170: 667688
    • (1970) Ann NY Acad Sci , vol.170 , pp. 667-688
    • Baker, L.E.1    Geddes, L.A.2
  • 2
    • 0013924158 scopus 로고
    • A comparison of linear and non-linear characterizations of impedance spirometry data
    • Baker L, Geddes L, Hoff H. A comparison of linear and non-linear characterizations of impedance spirometry data. Med Biol Eng Comput 1966; 4: 371379
    • (1966) Med Biol Eng Comput , Issue.4 , pp. 371-379
    • Baker, L.1    Geddes, L.2    Hoff, H.3
  • 3
    • 0013951790 scopus 로고
    • Physiological factors underlying transthoracic impedance variations in respiration
    • Baker LE, Geddes LA, Hoff HE, Chaput CJ. Physiological factors underlying transthoracic impedance variations in respiration. J Appl Physiol 1966; 21: 14911499
    • (1966) J Appl Physiol , vol.21 , pp. 1491-1499
    • Baker, L.E.1    Geddes, L.A.2    Hoff, H.E.3    Chaput, C.J.4
  • 4
    • 34250190592 scopus 로고    scopus 로고
    • An official American Thoracic Society/European Respiratory Society statement: Pulmonary function testing in preschool children
    • Beydon N, Davis SD, Lombardi E, et al. An official American Thoracic Society/European Respiratory Society statement: Pulmonary function testing in preschool children. Am J Respir Crit Care Med 2007; 175: 13041345
    • (2007) Am J Respir Crit Care Med , vol.175 , pp. 1304-1345
    • Beydon, N.1    Davis, S.D.2    Lombardi, E.3
  • 5
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 1996; 41: 22512269
    • (1996) Phys Med Biol , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 6
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • Geselowitz DB. An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans Biomed Eng 1971; 18: 3841
    • (1971) IEEE Trans Biomed Eng , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 7
    • 84965094053 scopus 로고
    • An electrical impedance spirometer
    • Goldensohn ES, Zablow L. An electrical impedance spirometer. J Appl Physiol 1959; 14: 463464
    • (1959) J Appl Physiol , vol.14 , pp. 463-464
    • Goldensohn, E.S.1    Zablow, L.2
  • 8
    • 0015417809 scopus 로고
    • Impedance pneumography. Comparison between chest impedance changes and respiratory volumes in 11 healthy volunteers
    • Grenvik A, Ballou S, McGinley E, Millen JE, Cooley WL, Safar P. Impedance pneumography. Comparison between chest impedance changes and respiratory volumes in 11 healthy volunteers. Chest 1972; 62: 439443
    • (1972) Chest , vol.62 , pp. 439-443
    • Grenvik, A.1    Ballou, S.2    McGinley, E.3    Millen, J.E.4    Cooley, W.L.5    Safar, P.6
  • 9
    • 28444489320 scopus 로고    scopus 로고
    • Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography
    • Hinz J, Moerer O, Neumann P, Dudykevych T, Hellige G, Quintel M. Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography. Eur J Anaesthesiol 2005; 22: 817825
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 817-825
    • Hinz, J.1    Moerer, O.2    Neumann, P.3    Dudykevych, T.4    Hellige, G.5    Quintel, M.6
  • 10
    • 33748860670 scopus 로고    scopus 로고
    • The effects of body mass index on lung volumes
    • Jones RL, Nzekwu M-MU. The effects of body mass index on lung volumes. Chest 2006; 130: 827833
    • (2006) Chest , vol.130 , pp. 827-833
    • Jones, R.L.1    Nzekwu, M.-M.U.2
  • 11
    • 0034490945 scopus 로고    scopus 로고
    • L o drup Carlsen K.C.
    • L o drup Carlsen KC. Tidal breathing at all ages. Monaldi Arch Chest Dis 2000; 55: 427434
    • (2000) Monaldi Arch Chest Dis , vol.55 , pp. 427-434
  • 12
    • 0014056239 scopus 로고
    • Factors affecting transthoracic impedance signals used to measure breathing
    • Logic JL, Maksud MG, Hamilton LH. Factors affecting transthoracic impedance signals used to measure breathing. J Appl Physiol 1967; 22: 251254
    • (1967) J Appl Physiol , vol.22 , pp. 251-254
    • Logic, J.L.1    Maksud, M.G.2    Hamilton, L.H.3
  • 13
    • 79952129171 scopus 로고    scopus 로고
    • A method for suppressing cardiogenic oscillations in impedance pneumography
    • Sepp a V-P, Hyttinen J, Viik J. A method for suppressing cardiogenic oscillations in impedance pneumography. Physiol Meas 2011; 32: 337345
    • (2011) Physiol Meas , Issue.32 , pp. 337-345
    • Seppa, V.-P.1    Hyttinen, J.2    Viik, J.3
  • 14
    • 84886527104 scopus 로고    scopus 로고
    • Agreement between impedance pneumography and pneumotachograph in estimation of a tidal breathing parameter
    • Sepp a V-P, Hyttinen J, Viik J. Agreement between impedance pneumography and pneumotachograph in estimation of a tidal breathing parameter. Chest 2010; 138: 816A.
    • (2010) Chest , vol.816 A , pp. 138
    • Seppa, V.-P.1    Hyttinen, J.2    Viik, J.3
  • 15
    • 84876539988 scopus 로고    scopus 로고
    • Impedance pneumography for assessment of a tidal breathing parameter in patients with airway obstruction
    • Seppa V-P, Ko obi T, K ahonen M, Hyttinen J, Viik J. Impedance pneumography for assessment of a tidal breathing parameter in patients with airway obstruction. Eur Respir J 2011; 38: 219s.
    • (2011) Eur Respir J , vol.38
    • Seppa, V.-P.1    Koobi, T.2    Kahonen, M.3    Hyttinen, J.4    Viik, J.5
  • 16
    • 77955861759 scopus 로고    scopus 로고
    • Assessment of pulmonary flow using impedance pneumography
    • Sepp a V-P, Viik J, Hyttinen J. Assessment of pulmonary flow using impedance pneumography. IEEE Trans Biomed Eng 2010; 57: 2277-2285
    • (2010) IEEE Trans Biomed Eng , Issue.57 , pp. 2277-2285
    • Sepp, A.V.-P.1    Viik, J.2    Hyttinen, J.3
  • 17
    • 81555216779 scopus 로고    scopus 로고
    • Associations between fluctuations in lung function and asthma control in two populations with differing asthma severity
    • Thamrin C, Nydegger R, Stern G, et al. Associations between fluctuations in lung function and asthma control in two populations with differing asthma severity. Thorax 2011; 66: 1036-1042
    • (2011) Thorax , vol.66 , pp. 1036-1042
    • Thamrin, C.1    Nydegger, R.2    Stern, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.