메뉴 건너뛰기




Volumn 58, Issue 1, 2013, Pages 13-26

NInFEA: An embedded framework for the real-time evaluation of fetal ECG extraction algorithms

Author keywords

biomedical signal processing; DSP platforms; non invasive fetal ECG; real time processing

Indexed keywords

ADVANCED SIGNAL PROCESSING; BIOMEDICAL SIGNAL PROCESSING; DIGITAL SIGNAL PROCESSORS (DSP); DSP PLATFORMS; FETAL ECG; FETAL ELECTROCARDIOGRAMS; GENERAL PURPOSE PROCESSORS; REALTIME PROCESSING;

EID: 84876531999     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/bmt-2012-0018     Document Type: Article
Times cited : (13)

References (37)
  • 1
    • 0141539228 scopus 로고    scopus 로고
    • Investigation of blind source separation methods for extraction of fetal ECG
    • IEEE CCECE May 2003
    • Ananthanag K, Sahambi J. Investigation of blind source separation methods for extraction of fetal ECG. In: Canadian Conference on Electrical and Computer Engineering IEEE CCECE 2003, vol. 3, May 2003: 20212024
    • (2003) Canadian Conference on Electrical and Computer Engineering , vol.3 , pp. 2021-2024
    • Ananthanag, K.1    Sahambi, J.2
  • 6
    • 0027812550 scopus 로고
    • Blind beamforming for non-Gaussian signals
    • Cardoso J, Souloumiac A. Blind beamforming for non-Gaussian signals. IEE Proc F 1993; 140: 362370
    • (1993) IEE Proc F , vol.140 , pp. 362-370
    • Cardoso, J.1    Souloumiac, A.2
  • 7
    • 0034108045 scopus 로고    scopus 로고
    • Fetal electrocardiogram extraction by blind source subspace separation
    • De Lathauwer L, Moor BD, Vandewalle J. Fetal electrocardiogram extraction by blind source subspace separation. IEEE Trans Biomed Eng 2000; 47: 567572
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 567-572
    • De Lathauwer, L.1    Moor, B.D.2    Vandewalle, J.3
  • 10
    • 84876567688 scopus 로고    scopus 로고
    • Apparatus and method for detecting the fetal heart rate
    • U.S. Patent N.o. 7 532 May
    • Hayes-Gill B, James D, Crowe J, Pieri JF. Apparatus and method for detecting the fetal heart rate. U.S. Patent No. 7,532,923, May 2009
    • (2009) , pp. 923
    • Hayes-Gill, B.1    James, D.2    Crowe, J.3    Pieri, J.F.4
  • 11
    • 0042826822 scopus 로고    scopus 로고
    • Independent component analysis: Algorithms and applications
    • Hyvarinen A, Oja E. Independent component analysis: Algorithms and applications. Neural Netw 2000; 13: 411430
    • (2000) Neural Netw , vol.13 , pp. 411-430
    • Hyvarinen, A.1    Oja, E.2
  • 12
    • 14844306738 scopus 로고    scopus 로고
    • Fetal electrocardiogram extraction by sequential source separation in the wavelet domain
    • Jafari M, Chambers J. Fetal electrocardiogram extraction by sequential source separation in the wavelet domain. IEEE Trans Biomed Eng 2005; 52: 390400
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 390-400
    • Jafari, M.1    Chambers, J.2
  • 13
    • 0004230806 scopus 로고
    • 2nd Edition. London UK: Charles Griffin
    • Kendall M. Time-series, 2nd edition. London, UK: Charles Griffin 1976
    • (1976) Time-Series
    • Kendall, M.1
  • 14
    • 70450233509 scopus 로고    scopus 로고
    • Combined application of independent component analysis and projective filtering to fetal ECG extraction
    • Kotas M. Combined application of independent component analysis and projective filtering to fetal ECG extraction. Biocybern Biomed Eng 2008; 28: 7593
    • (2008) Biocybern Biomed Eng , vol.28 , pp. 75-93
    • Kotas, M.1
  • 17
    • 34548309267 scopus 로고    scopus 로고
    • Real-time fetal ECG extraction with JADE on a floating point DSP
    • Muceli S, Pani D, Raffo L. Real-time fetal ECG extraction with JADE on a floating point DSP. Electron Lett 2007; 43: 963965
    • (2007) Electron Lett , vol.43 , pp. 963-965
    • Muceli, S.1    Pani, D.2    Raffo, L.3
  • 18
    • 55649112694 scopus 로고    scopus 로고
    • Non-invasive real-time fetal ECG extraction: A block-on-line DSP implementation based on the JADE algorithm
    • Muceli S, Pani D, Raffo L. Non-invasive real-time fetal ECG extraction: A block-on-line DSP implementation based on the JADE algorithm. BIOSIGNALS 2008; 2: 458463
    • (2008) BIOSIGNALS , vol.2 , pp. 458-463
    • Muceli, S.1    Pani, D.2    Raffo, L.3
  • 20
    • 84876577006 scopus 로고    scopus 로고
    • OMAP-L137 evaluation moduletechnical reference
    • OMAP-L137 Evaluation ModuleTechnical Reference, Spectrum Digital Inc., 2008
    • (2008) Spectrum Digital Inc.
  • 21
    • 84876532237 scopus 로고    scopus 로고
    • online articles. [Online]. Available ati OMAPL1. Accessed 9 December
    • Omap-l137 online articles. [Online]. Available at: Http:// processors.wiki.ti.com/index.php/Category:OMAPL1. Accessed 9 December, 2012
    • (2012) Omap-l137
  • 22
    • 0024810690 scopus 로고
    • The effect of changes in the conductive medium on the fetal ECG throughout gestation
    • Oostendorp TF, van Oosterom A, Jongsma HW. The effect of changes in the conductive medium on the fetal ECG throughout gestation. Clin Phys Physiol Meas 1989; 10: 1120
    • (1989) Clin Phys Physiol Meas , vol.10 , pp. 11-20
    • Oostendorp, T.F.1    Van Oosterom, A.2    Jongsma, H.W.3
  • 25
    • 79953809544 scopus 로고    scopus 로고
    • Real-time back-projection of fetal ecg sources in ol-jade for the optimization of blind electrodes positioning
    • " Qt 4.6.3 online reference documentation. " [Online]. Available at 2012 Accessed 9 December
    • Pani D, Argiolas S, Raffo L. Real-time back-projection of fetal ECG sources in OL-JADE for the optimization of blind electrodes positioning. In: 37th International Conference on Computing in Cardiology, 2010: 289292 " Qt 4.6.3 online reference documentation. " [Online]. Available at: Http://doc.qt.digia.com/4.6/. Accessed 9 December, 2012
    • (2010) 37th International Conference on Computing in Cardiology , pp. 289-292
    • Pani, D.1    Argiolas, S.2    Raffo, L.3
  • 27
    • 79959696370 scopus 로고    scopus 로고
    • A review of fetal ECG signal processing; issues and promising directions
    • Sameni R, Clifford GD. A review of fetal ECG signal processing; issues and promising directions. Open Pacing Electrophysiol Ther J 2010; 3: 4-20
    • (2010) Open Pacing Electrophysiol Ther J , Issue.3 , pp. 4-20
    • Sameni, R.1    Clifford, G.D.2
  • 28
    • 33846350199 scopus 로고    scopus 로고
    • A novel extraction method of fetal electrocardiogram from the composite abdominal signal
    • Sato M, Kimura Y, Chida S, et al. A novel extraction method of fetal electrocardiogram from the composite abdominal signal. IEEE Trans Biomed Eng 2007; 54: 4958
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 49-58
    • Sato, M.1    Kimura, Y.2    Chida, S.3
  • 30
    • 51749106065 scopus 로고    scopus 로고
    • Blind signal separation and its application to long-term bio-medical monitoring
    • Nov
    • Spence G, Clarke I, Smith M. Blind signal separation and its application to long-term bio-medical monitoring. In: Medical Applications of Signal Processing, Nov 2005: 9398
    • (2005) Medical Applications of Signal Processing , pp. 93-98
    • Spence, G.1    Clarke, I.2    Smith, M.3
  • 31
    • 0028420006 scopus 로고
    • Nonlinear transforms of ECG signals for digital QRS detection: A quantitative analysis
    • Suppappola S, Sun Y. Nonlinear transforms of ECG signals for digital QRS detection: A quantitative analysis. IEEE Trans Biomed Eng 1994; 41: 397400
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 397-400
    • Suppappola, S.1    Sun, Y.2
  • 32
    • 0038507616 scopus 로고    scopus 로고
    • Non-invasive fetal electrocardiography in singleton and multiple pregnancies
    • Taylor MJ, Smith MJ, Thomas M, et al. Non-invasive fetal electrocardiography in singleton and multiple pregnancies. BJOG 2003; 110: 668678
    • (2003) BJOG , vol.110 , pp. 668-678
    • Taylor, M.J.1    Smith, M.J.2    Thomas, M.3
  • 33
    • 84876553967 scopus 로고    scopus 로고
    • Mar LNK058USR Texas Instruments Inc.
    • TI, DSP/BIOS Link User Guide. Texas Instruments Inc., Mar 2009, LNK058USR
    • (2009) TI, DSP/BIOS Link User Guide
  • 36
    • 0016643045 scopus 로고
    • Adaptive noise cancelling: Principles and applications
    • Widrow B, Glover JR, Mccool JM, et al. Adaptive noise cancelling: Principles and applications. Proc IEEE 1975; 63: 16921716
    • (1975) Proc IEEE , vol.63 , pp. 1692-1716
    • Widrow, B.1    Glover, J.R.2    Mccool, J.M.3
  • 37
    • 0035113616 scopus 로고    scopus 로고
    • Noninvasive fetal electrocardiogram extraction: Blind separation versus adaptive noise cancellation
    • [ Zarzoso V, Nandi AK. Noninvasive fetal electrocardiogram extraction: Blind separation versus adaptive noise cancellation. IEEE Trans Biomed Eng 2001; 48: 1218
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 12-18
    • Zarzoso, V.1    Nandi, A.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.