메뉴 건너뛰기




Volumn 2, Issue , 2006, Pages 1335-1342

Design model and load reduction assessment for multi-rotational mode individual pitch control (higher harmonics control)

Author keywords

Control design model; Higher harmonics control; Individual pitch control; Rotational modes

Indexed keywords

AERO-ELASTIC SIMULATIONS; CO-ORDINATE TRANSFORMATION; CONTROL DESIGN; HIGHER HARMONICS; INDIVIDUAL PITCH CONTROL; ROTATIONAL FREQUENCY; ROTATIONAL MODES; VARIABLE SPEED WIND TURBINES;

EID: 84876531188     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (82)

References (13)
  • 3
    • 84870510963 scopus 로고    scopus 로고
    • Morphological study of aeroelastic control concepts for wind turbines
    • to be published in May 2006, ECN Wind Energy, Petten, the Netherlands
    • T.G. van Engelen, D. Winkelaar, H. Markou (Risø), T. Buhl (Risø), B. Marrant (TU Delft), Mor- phological Study of Aeroelastic Control Concepts for Wind Turbines, StabCon Task-7 Report, to be published in May 2006, ECN Wind Energy, Petten, the Netherlands
    • StabCon Task-7 Report
    • Van Engelen, T.G.1    Winkelaar, D.2    Markou, H.3    Buhl, T.4    Marrant, B.5
  • 9
    • 5244273311 scopus 로고
    • Atmospheric turbulence characteristics in the rotating frame of reference of a WECS rotor
    • Spain
    • J.B. Dragt, Atmospheric Turbulence Character- istics in the Rotating Frame of Reference of a WECS Rotor; in Proceedings of European Wind Energy Conference in Madrid, Spain, 1990.
    • (1990) Proceedings of European Wind Energy Conference in Madrid
    • Dragt, J.B.1
  • 11
    • 37249021107 scopus 로고    scopus 로고
    • TURBU offshore computer program for frequency domain analysis of horizontal axis offshore wind turbines
    • ECN Wind Energy, ECN Petten, the Netherlands
    • T.G. van Engelen, H. Braam, TURBU Offshore, Computer Program for Frequency Domain Analysis of Horizontal Axis Offshore Wind Turbines; Implemen- tation; Technical Report ECN-C-04-079, ECN Wind Energy, ECN Petten, the Netherlands.
    • Implementation; Technical Report ECN-C-04-079
    • Van Engelen, T.G.1    Braam, H.2
  • 12
    • 85115243338 scopus 로고
    • Cumulative damage in fatigue
    • M.A. Miner, Cumulative damage in fatigue; in Journal of Applied Mechanics, 12:159-164, 1945
    • (1945) Journal of Applied Mechanics , vol.12 , pp. 159-164
    • Miner, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.