메뉴 건너뛰기




Volumn 116, Issue 4, 2013, Pages 829-835

Ultrasound estimates for midline epidural punctures in the obese parturient: Paramedian sagittal oblique is comparable to transverse median plane

Author keywords

[No Author keywords available]

Indexed keywords

ADIPOSE TISSUE; ADULT; ANESTHESIST; ARTICLE; BODY MASS; CESAREAN SECTION; DURA MATER; ECHOGRAPHY; EPIDURAL ANESTHESIA; EPIDURAL NEEDLE; EPIDURAL SPACE; FEMALE; HUMAN; IMAGE QUALITY; LIGAMENTUM FLAVUM; MAJOR CLINICAL STUDY; MATERNAL OBESITY; OBSTETRIC ANESTHESIA; PATIENT COMFORT; POSTERIOR LONGITUDINAL LIGAMENT; PREGNANT WOMAN; PRIORITY JOURNAL; PUNCTURE; SPINAL ANESTHESIA; VERTEBRA; VERTEBRA BODY; VERTEBRAL CANAL;

EID: 84876518604     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0b013e31827f55f0     Document Type: Article
Times cited : (44)

References (15)
  • 1
    • 0036265202 scopus 로고    scopus 로고
    • Epidural catheter function during labor predicts anesthetic efficacy for subsequent cesarean delivery
    • Riley ET, Papasin J. Epidural catheter function during labor predicts anesthetic efficacy for subsequent cesarean delivery. Int J Obstet Anesth 2002;11:81-4
    • (2002) Int J Obstet Anesth , vol.11 , pp. 81-84
    • Riley, E.T.1    Papasin, J.2
  • 2
    • 0027146662 scopus 로고
    • Anesthetic and obstetric outcome in morbidly obese parturients
    • Hood DD, Dewan DM. Anesthetic and obstetric outcome in morbidly obese parturients. Anesthesiology 1993;79:1210-8
    • (1993) Anesthesiology , vol.79 , pp. 1210-1218
    • Hood, D.D.1    Dewan, D.M.2
  • 3
    • 33947099962 scopus 로고    scopus 로고
    • Complications of neuraxial anesthesia in an extreme morbidly obese patient for cesarean section
    • Whitty RJ, Maxwell CV, Carvalho JC. Complications of neuraxial anesthesia in an extreme morbidly obese patient for cesarean section. Int J Obstet Anesth 2007;16:139-44
    • (2007) Int J Obstet Anesth , vol.16 , pp. 139-144
    • Whitty, R.J.1    Maxwell, C.V.2    Carvalho, J.C.3
  • 6
    • 34247511436 scopus 로고    scopus 로고
    • Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals
    • Arzola C, Davies S, Rofaeel A, Carvalho JC. Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals. Anesth Analg 2007;104:1188-92
    • (2007) Anesth Analg , vol.104 , pp. 1188-1192
    • Arzola, C.1    Davies, S.2    Rofaeel, A.3    Carvalho, J.C.4
  • 7
    • 66349122938 scopus 로고    scopus 로고
    • Ultrasound imaging of the lumbar spine in the transverse plane: The correlation between estimated and actual depth to the epidural space in obese parturients
    • Balki M, Lee Y, Halpern S, Carvalho JC. Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg 2009;108:1876-81
    • (2009) Anesth Analg , vol.108 , pp. 1876-1881
    • Balki, M.1    Lee, Y.2    Halpern, S.3    Carvalho, J.C.4
  • 10
    • 79958121165 scopus 로고    scopus 로고
    • Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade
    • Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology 2011;114:1459-85
    • (2011) Anesthesiology , vol.114 , pp. 1459-1485
    • Chin, K.J.1    Karmakar, M.K.2    Peng, P.3
  • 11
    • 39749167926 scopus 로고    scopus 로고
    • Ultrasound-facilitated epidurals and spinals in obstetrics
    • Carvalho JC. Ultrasound-facilitated epidurals and spinals in obstetrics. Anesthesiol Clin 2008;26:145-58
    • (2008) Anesthesiol Clin , vol.26 , pp. 145-158
    • Carvalho, J.C.1
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 15
    • 0035974274 scopus 로고    scopus 로고
    • A generalized concordance correlation coefficient for continuous and categorical data
    • King TS, Chinchilli VM. A generalized concordance correlation coefficient for continuous and categorical data. Stat Med 2001;20:2131-47
    • (2001) Stat Med , vol.20 , pp. 2131-2147
    • King, T.S.1    Chinchilli, V.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.