Volumn 69, Issue 5, 2013, Pages 1438-1442

Integration of the computational fluid dynamics technique with MRI in aortic dissections

Author keywords

3D time resolved magnetic resonance angiography; 4D phase contrast magnetic resonance angiography; aortic dissections; computational fluid dynamics

Indexed keywords

ANGIOGRAPHY; BLOOD VESSELS; DECISION MAKING; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; MAGNETISM; PATIENT TREATMENT; RESONANCE;

EID: 84876492748     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24376     Document Type: Review
Times cited : (16)

References (40)
  • 10
    • 35748971461 scopus 로고    scopus 로고
    • Complicated acute type B dissection and endovascular repair: Indications and pitfalls
    • Moon MC, Pablo Morales J, Greenberg RK,. Complicated acute type B dissection and endovascular repair: indications and pitfalls. Perspect Vasc Surg Endovasc Therapy 2007; 19: 146-159.
    • (2007) Perspect Vasc Surg Endovasc Therapy , vol.19 , pp. 146-159
    • Moon, M.C.1    Pablo Morales, J.2    Greenberg, R.K.3
  • 11
    • 84860153985 scopus 로고    scopus 로고
    • Simultaneous fenestration with stent implantation for acute limb ischemia due to type B acute aortic dissection complicated with both static and dynamic obstructions
    • Narita K, Akutsu K, Yamamoto T, Sato N, Murata S, Mizuno K, Tanaka K,. Simultaneous fenestration with stent implantation for acute limb ischemia due to type B acute aortic dissection complicated with both static and dynamic obstructions. Ann Thorac Cardiovasc Surg 2012; 18: 158-161.
    • (2012) Ann Thorac Cardiovasc Surg , vol.18 , pp. 158-161
    • Narita, K.1    Akutsu, K.2    Yamamoto, T.3    Sato, N.4    Murata, S.5    Mizuno, K.6    Tanaka, K.7
  • 12
    • 34250630934 scopus 로고    scopus 로고
    • Management of vital organ malperfusion in acute aortic dissection: Proposal of a mechanism-specific approach
    • Shiiya N, Matsuzaki K, Kunihara T, Murashita T, Matsui Y,. Management of vital organ malperfusion in acute aortic dissection: proposal of a mechanism-specific approach. Gen Thorac Cardiovasc Surg 2007; 55: 85-90.
    • (2007) Gen Thorac Cardiovasc Surg , vol.55 , pp. 85-90
    • Shiiya, N.1    Matsuzaki, K.2    Kunihara, T.3    Murashita, T.4    Matsui, Y.5
  • 14
    • 84860383271 scopus 로고    scopus 로고
    • A morphologic study of chronic type B aortic dissections and aneurysms after thoracic endovascular stent grafting
    • Qing KX, Yiu WK, Cheng SW,. A morphologic study of chronic type B aortic dissections and aneurysms after thoracic endovascular stent grafting. J Vasc Surg 2012; 55: 1268-1276.
    • (2012) J Vasc Surg , vol.55 , pp. 1268-1276
    • Qing, K.X.1    Yiu, W.K.2    Cheng, S.W.3
  • 15
    • 84860378858 scopus 로고    scopus 로고
    • Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections
    • Karmonik C, Duran C, Shah DJ, Anaya-Ayala JE, Davies MG, Lumsden AB, Bismuth J,. Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections. J Vasc Surg 2012; 55: 1419-1426.
    • (2012) J Vasc Surg , vol.55 , pp. 1419-1426
    • Karmonik, C.1    Duran, C.2    Shah, D.J.3    Anaya-Ayala, J.E.4    Davies, M.G.5    Lumsden, A.B.6    Bismuth, J.7
  • 16
    • 74549173015 scopus 로고    scopus 로고
    • Microstructural damage in arterial tissue exposed to repeated tensile strains
    • Austin N, DiFrancesco LM, Herzog W,. Microstructural damage in arterial tissue exposed to repeated tensile strains. J Manipulative Physiol Ther 2010; 33: 14-19.
    • (2010) J Manipulative Physiol Ther , vol.33 , pp. 14-19
    • Austin, N.1    Difrancesco, L.M.2    Herzog, W.3
  • 17
    • 0029587668 scopus 로고
    • Control of endothelial cell gene expression by flow
    • Malek AM, Izumo S,. Control of endothelial cell gene expression by flow. J Biomech 1995; 28: 1515-1528.
    • (1995) J Biomech , vol.28 , pp. 1515-1528
    • Malek, A.M.1    Izumo, S.2
  • 21
  • 22
    • 80054874657 scopus 로고    scopus 로고
    • A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent
    • Clough RE, Hussain T, Uribe S, Greil GF, Razavi R, Taylor PR, Schaeffter T, Waltham M,. A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent. J Vasc Surg 2011; 54 (5): 1251-1258.
    • (2011) J Vasc Surg , vol.54 , Issue.5 , pp. 1251-1258
    • Clough, R.E.1    Hussain, T.2    Uribe, S.3    Greil, G.F.4    Razavi, R.5    Taylor, P.R.6    Schaeffter, T.7    Waltham, M.8
  • 24
    • 58249104079 scopus 로고    scopus 로고
    • Hemodynamics in a lethal basilar artery aneurysm just before its rupture
    • Cebral JR, Hendrickson S, Putman CM,. Hemodynamics in a lethal basilar artery aneurysm just before its rupture. Am J Neuroradiol 2009; 30: 95-98.
    • (2009) Am J Neuroradiol , vol.30 , pp. 95-98
    • Cebral, J.R.1    Hendrickson, S.2    Putman, C.M.3
  • 27
  • 28
    • 33645465949 scopus 로고    scopus 로고
    • Analysis and computer program for rupture-risk prediction of abdominal aortic aneurysms
    • Kleinstreuer C, Li Z,. Analysis and computer program for rupture-risk prediction of abdominal aortic aneurysms. Biomed Eng Online 2006; 5: 19.
    • (2006) Biomed Eng Online , vol.5 , pp. 19
    • Kleinstreuer, C.1    Li, Z.2
  • 29
    • 34447290302 scopus 로고    scopus 로고
    • Fluid-structure interaction analyses of stented abdominal aortic aneurysms
    • Kleinstreuer C, Li Z, Farber MA,. Fluid-structure interaction analyses of stented abdominal aortic aneurysms. Annu Rev Biomed Eng 2007; 9: 169-204.
    • (2007) Annu Rev Biomed Eng , vol.9 , pp. 169-204
    • Kleinstreuer, C.1    Li, Z.2    Farber, M.A.3
  • 30
    • 18044393022 scopus 로고    scopus 로고
    • Blood flow and structure interactions in a stented abdominal aortic aneurysm model
    • Li Z, Kleinstreuer C,. Blood flow and structure interactions in a stented abdominal aortic aneurysm model. Med Eng Phys 2005; 27: 369-382.
    • (2005) Med Eng Phys , vol.27 , pp. 369-382
    • Li, Z.1    Kleinstreuer, C.2
  • 31
    • 42949160153 scopus 로고    scopus 로고
    • Blood flow in cerebral aneurysms: Comparison of phase contrast magnetic resonance and computational fluid dynamics - Preliminary experience
    • Karmonik C, Klucznik R, Benndorf G,. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics-preliminary experience. Rofo 2008; 180: 209-215.
    • (2008) Rofo , vol.180 , pp. 209-215
    • Karmonik, C.1    Klucznik, R.2    Benndorf, G.3
  • 32
    • 33748329507 scopus 로고    scopus 로고
    • Estimating the hemodynamic impact of interventional treatments of aneurysms: Numerical simulation with experimental validation: Technical case report
    • author reply E429-E430
    • Acevedo-Bolton G, Jou LD, Dispensa BP, Lawton MT, Higashida RT, Martin AJ, Young WL, Saloner D,. Estimating the hemodynamic impact of interventional treatments of aneurysms: numerical simulation with experimental validation: technical case report. Neurosurgery 2006; 59: E429-E430; author reply E429-E430.
    • (2006) Neurosurgery , vol.59
    • Acevedo-Bolton, G.1    Jou, L.D.2    Dispensa, B.P.3    Lawton, M.T.4    Higashida, R.T.5    Martin, A.J.6    Young, W.L.7    Saloner, D.8
  • 33
    • 80855134306 scopus 로고    scopus 로고
    • Flow characteristics in a canine aneurysm model: A comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations
    • Jiang J, Johnson K, Valen-Sendstad K, Mardal KA, Wieben O, Strother C,. Flow characteristics in a canine aneurysm model: a comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations. Med Phys 2011; 38: 6300-6312.
    • (2011) Med Phys , vol.38 , pp. 6300-6312
    • Jiang, J.1    Johnson, K.2    Valen-Sendstad, K.3    Mardal, K.A.4    Wieben, O.5    Strother, C.6
  • 35
    • 79953878322 scopus 로고    scopus 로고
    • A computational fluid dynamics study pre- and post-stent graft placement in an acute type B aortic dissection
    • Karmonik C, Bismuth J, Davies MG, Shah DJ, Younes HK, Lumsden AB,. A computational fluid dynamics study pre- and post-stent graft placement in an acute type B aortic dissection. Vasc Endovasc Surg 2011; 45: 157-164.
    • (2011) Vasc Endovasc Surg , vol.45 , pp. 157-164
    • Karmonik, C.1    Bismuth, J.2    Davies, M.G.3    Shah, D.J.4    Younes, H.K.5    Lumsden, A.B.6
  • 36
    • 79960935985 scopus 로고    scopus 로고
    • Computational study of haemodynamic effects of entry- and exit-tear coverage in a DeBakey type III aortic dissection: Technical report
    • Karmonik C, Bismuth J, Shah DJ, Davies MG, Purdy D, Lumsden AB,. Computational study of haemodynamic effects of entry- and exit-tear coverage in a DeBakey type III aortic dissection: technical report. Eur J Vasc Endovasc Surg 2011; 42: 172-177.
    • (2011) Eur J Vasc Endovasc Surg , vol.42 , pp. 172-177
    • Karmonik, C.1    Bismuth, J.2    Shah, D.J.3    Davies, M.G.4    Purdy, D.5    Lumsden, A.B.6
  • 40
    • 84859158435 scopus 로고    scopus 로고
    • A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging
    • Clough RE, Waltham M, Giese D, Taylor PR, Schaeffter T,. A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging. J Vasc Surg 2012; 55: 914-923.
    • (2012) J Vasc Surg , vol.55 , pp. 914-923
    • Clough, R.E.1    Waltham, M.2    Giese, D.3    Taylor, P.R.4    Schaeffter, T.5