-
1
-
-
85168044922
-
-
National Drug Intelligence Bureau (NDIB), Monthly Illicit Drug Assessment, Wellington, New Zealand
-
National Drug Intelligence Bureau (NDIB), Monthly Illicit Drug Assessment, Wellington, New Zealand, 2012.
-
(2012)
-
-
-
2
-
-
85168046924
-
-
United Nations Office on Drugs and Crime (UNODC), World Drug Report
-
United Nations Office on Drugs and Crime (UNODC), World Drug Report, 2009.
-
(2009)
-
-
-
3
-
-
0025674416
-
Methamphetamine synthesis via hydriodic acid red phosphorous reduction of ephedrine
-
Skinner H.F. Methamphetamine synthesis via hydriodic acid red phosphorous reduction of ephedrine. Forensic Sci. Int. 1990, 48(2):123-134.
-
(1990)
Forensic Sci. Int.
, vol.48
, Issue.2
, pp. 123-134
-
-
Skinner, H.F.1
-
4
-
-
84863477448
-
Investigation of the reaction impurities associated with methylamphetamine synthesized using the Nagai method
-
Kunalan V., Kerr W.J., Nic Daéid N. Investigation of the reaction impurities associated with methylamphetamine synthesized using the Nagai method. Anal. Chem. 2012, 84(13):5744-5752.
-
(2012)
Anal. Chem.
, vol.84
, Issue.13
, pp. 5744-5752
-
-
Kunalan, V.1
Kerr, W.J.2
Nic Daéid, N.3
-
5
-
-
76849092551
-
Significant determinants of isotope composition during hi/p-red synthesis of methamphetamine
-
David G.E., Hibbert D.B., Frew R.D., Hayman A.R. Significant determinants of isotope composition during hi/p-red synthesis of methamphetamine. Aust. J. Chem. 2010, 63(1):22-29.
-
(2010)
Aust. J. Chem.
, vol.63
, Issue.1
, pp. 22-29
-
-
David, G.E.1
Hibbert, D.B.2
Frew, R.D.3
Hayman, A.R.4
-
9
-
-
0036210356
-
Microfluidic chips for clinical and forensic analysis
-
Verpoorte E. Microfluidic chips for clinical and forensic analysis. Electophoresis 2002, 23(5):677-712.
-
(2002)
Electophoresis
, vol.23
, Issue.5
, pp. 677-712
-
-
Verpoorte, E.1
-
10
-
-
79960349106
-
A rapid method for the in-field analysis of amphetamines employing the Agilent bioanalyzer
-
Lloyd A., Blanes L., Beavis A., Roux C., Doble P. A rapid method for the in-field analysis of amphetamines employing the Agilent bioanalyzer. Anal. Method 2011, 3(7):1535-1539.
-
(2011)
Anal. Method
, vol.3
, Issue.7
, pp. 1535-1539
-
-
Lloyd, A.1
Blanes, L.2
Beavis, A.3
Roux, C.4
Doble, P.5
-
11
-
-
0030032860
-
A convenient derivatization method for the determination of amphetamine and related drugs in urine
-
Jonsson J., Kronstrand R., Hatanpaa M. A convenient derivatization method for the determination of amphetamine and related drugs in urine. J. Forensic. Sci. 1996, 41(1):148-151.
-
(1996)
J. Forensic. Sci.
, vol.41
, Issue.1
, pp. 148-151
-
-
Jonsson, J.1
Kronstrand, R.2
Hatanpaa, M.3
-
12
-
-
69749110822
-
Characterization of route specific impurities found in methamphetamine synthesized by the leuckart and reductive amination methods
-
Kunalan V., Daeid N.N., Kerr W.J., Buchanan H.A.S., McPherson A.R. Characterization of route specific impurities found in methamphetamine synthesized by the leuckart and reductive amination methods. Anal. Chem. 2009, 81(17):7342-7348.
-
(2009)
Anal. Chem.
, vol.81
, Issue.17
, pp. 7342-7348
-
-
Kunalan, V.1
Daeid, N.N.2
Kerr, W.J.3
Buchanan, H.A.S.4
McPherson, A.R.5
-
13
-
-
77049125243
-
Recoveries of trace pseudoephedrine and methamphetamine residues from impermeable household surfaces: Implications for sampling methods used during remediation of clandestine methamphetamine laboratories
-
Abdullah A.F.L., Miskelly G.M. Recoveries of trace pseudoephedrine and methamphetamine residues from impermeable household surfaces: Implications for sampling methods used during remediation of clandestine methamphetamine laboratories. Talanta 2010, 81(1/2):455-461.
-
(2010)
Talanta
, vol.81
, Issue.1-2
, pp. 455-461
-
-
Abdullah, A.F.L.1
Miskelly, G.M.2
-
14
-
-
0031830518
-
Micromachined heated chemical reactor for pre-column derivatisation
-
Eijkel J.C.T., Prak A., Cowen S., Craston D.H., Manz A. Micromachined heated chemical reactor for pre-column derivatisation. J. Chromatogr. A 1998, 815(2):265-271.
-
(1998)
J. Chromatogr. A
, vol.815
, Issue.2
, pp. 265-271
-
-
Eijkel, J.C.T.1
Prak, A.2
Cowen, S.3
Craston, D.H.4
Manz, A.5
-
15
-
-
38749100962
-
Electrophoresis PDMS/glass chips with continuous on-chip derivatization and analysis of amino acids using naphthalene-2,3-dicarboxaldehyde as fluorogenic agent
-
Yassine O., Morin P., Dispagne O., Renaud L., Denoroy L., Kleimann P., Faure K., Rocca J.L., Ouaini N., Ferrigno R. Electrophoresis PDMS/glass chips with continuous on-chip derivatization and analysis of amino acids using naphthalene-2,3-dicarboxaldehyde as fluorogenic agent. Anal. Chim. Acta 2008, 609(2):215-222.
-
(2008)
Anal. Chim. Acta
, vol.609
, Issue.2
, pp. 215-222
-
-
Yassine, O.1
Morin, P.2
Dispagne, O.3
Renaud, L.4
Denoroy, L.5
Kleimann, P.6
Faure, K.7
Rocca, J.L.8
Ouaini, N.9
Ferrigno, R.10
|