메뉴 건너뛰기




Volumn 79, Issue 3-4, 2013, Pages 551-557

A novel impermeable adhesive membrane to reinforce dural closure: A preliminary retrospective study on 119 consecutive high-risk patients

Author keywords

Cerebrospinal fluid leak; Dural repair; Dural sealant; Duraplasty; TissuePatchDural

Indexed keywords

CORTICOSTEROID; IMPERMEABLE ADHESIVE MEMBRANE; SURGICAL GLUE; UNCLASSIFIED DRUG;

EID: 84876418985     PISSN: 18788750     EISSN: 18788769     Source Type: Journal    
DOI: 10.1016/j.wneu.2011.09.022     Document Type: Review
Times cited : (26)

References (44)
  • 1
    • 56749136231 scopus 로고    scopus 로고
    • Watertight dural closure: Is it necessary? A prospective randomized trial in patients with supratentorial craniotomies
    • M. Barth, J. Tuettenberg, C. Thomé, C. Weiss, P. Vajkoczy, P. Schmiedek Watertight dural closure: is it necessary? A prospective randomized trial in patients with supratentorial craniotomies Neurosurgery 63 4 Suppl 2 2008 352 358
    • (2008) Neurosurgery , vol.63 , Issue.4 SUPPL. 2 , pp. 352-358
    • Barth, M.1    Tuettenberg, J.2    Thomé, C.3    Weiss, C.4    Vajkoczy, P.5    Schmiedek, P.6
  • 2
    • 0000178693 scopus 로고    scopus 로고
    • A review of dural substitutes used in neurosurgery
    • R. Berjano, F.C. Vinas, M. Dujovny A review of dural substitutes used in neurosurgery Crit Rev Neurosurg 9 1999 217 222
    • (1999) Crit Rev Neurosurg , vol.9 , pp. 217-222
    • Berjano, R.1    Vinas, F.C.2    Dujovny, M.3
  • 4
    • 21744439094 scopus 로고    scopus 로고
    • Use of a novel absorbable hydrogel for augmentation of dural repair: Results of a preliminary clinical study
    • J.D. Boogaarts, J.A. Grotenhuis, R.H. Bartels, T. Beems Use of a novel absorbable hydrogel for augmentation of dural repair: results of a preliminary clinical study Neurosurgery 57 1 Suppl 2005 146 151
    • (2005) Neurosurgery , vol.57 , Issue.1 SUPPL. , pp. 146-151
    • Boogaarts, J.D.1    Grotenhuis, J.A.2    Bartels, R.H.3    Beems, T.4
  • 5
    • 0025836984 scopus 로고
    • Silastic duraplasty in pediatric patients
    • F.A. Boop, W.M. Chadduck Silastic duraplasty in pediatric patients Neurosurgery 29 1991 785 788
    • (1991) Neurosurgery , vol.29 , pp. 785-788
    • Boop, F.A.1    Chadduck, W.M.2
  • 6
    • 68249138351 scopus 로고    scopus 로고
    • Treatment of cerebrospinal fluid leaks in high-risk patients
    • B. Boudreaux, J.E. Zins Treatment of cerebrospinal fluid leaks in high-risk patients J Craniofac Surg 20 2009 743 747
    • (2009) J Craniofac Surg , vol.20 , pp. 743-747
    • Boudreaux, B.1    Zins, J.E.2
  • 10
    • 0001795318 scopus 로고
    • Surgery of the head
    • W.W. Keen, W.B. Saunders Philadelphia
    • H. Cushing Surgery of the head W.W. Keen, Surgery, Its Principles and Practice Vol III 1908 W.B. Saunders Philadelphia 17 276
    • (1908) Surgery, Its Principles and Practice , vol.3 , pp. 17-276
    • Cushing, H.1
  • 11
    • 33644917990 scopus 로고    scopus 로고
    • Experience with acellular human dura and bovine collagen matrix for duraplasty after posterior fossa decompression for Chiari malformations
    • S.F. Danish, A. Samdani, A. Hanna, P. Storm, L. Sutton Experience with acellular human dura and bovine collagen matrix for duraplasty after posterior fossa decompression for Chiari malformations J Neurosurg 104 1 Suppl 2006 16 20
    • (2006) J Neurosurg , vol.104 , Issue.1 SUPPL. , pp. 16-20
    • Danish, S.F.1    Samdani, A.2    Hanna, A.3    Storm, P.4    Sutton, L.5
  • 12
    • 77957325084 scopus 로고    scopus 로고
    • Use of a new absorbable sealing film for preventing postoperative cerebrospinal fluid leaks: Remarks on a new approach
    • A. Della Puppa, M. Rossetto, R. Scienza Use of a new absorbable sealing film for preventing postoperative cerebrospinal fluid leaks: remarks on a new approach Br J Neurosurg 24 2010 609 611
    • (2010) Br J Neurosurg , vol.24 , pp. 609-611
    • Della Puppa, A.1    Rossetto, M.2    Scienza, R.3
  • 13
    • 0016342169 scopus 로고
    • Postoperative cerebrospinal fluid fistulas and their treatment
    • Z. Djordjevic, B. Milosavlijevic Postoperative cerebrospinal fluid fistulas and their treatment J Neurosurg Sci 18 1974 109 111
    • (1974) J Neurosurg Sci , vol.18 , pp. 109-111
    • Djordjevic, Z.1    Milosavlijevic, B.2
  • 17
    • 0024597620 scopus 로고
    • Spinal cord compression: A complication of silicone-coated Dacron dural grafts Report of two cases
    • H. Gomez, J.R. Little Spinal cord compression: a complication of silicone-coated Dacron dural grafts Report of two cases Neurosurgery 24 1989 115 118
    • (1989) Neurosurgery , vol.24 , pp. 115-118
    • Gomez, H.1    Little, J.R.2
  • 18
    • 27744434071 scopus 로고    scopus 로고
    • Costs of postoperative cerebrospinal fluid leakage: 1-year, retrospective analysis of 412 consecutive nontrauma cases
    • J.A. Grotenhuis Costs of postoperative cerebrospinal fluid leakage: 1-year, retrospective analysis of 412 consecutive nontrauma cases Surg Neurol 64 2005 490 494
    • (2005) Surg Neurol , vol.64 , pp. 490-494
    • Grotenhuis, J.A.1
  • 19
    • 0028816242 scopus 로고
    • Complications to the use of Vicryl-collagen dural substitute
    • G. Gudmundsson, I. Sogaard Complications to the use of Vicryl-collagen dural substitute Acta Neurochir (Wien) 132 1995 145 147
    • (1995) Acta Neurochir (Wien) , vol.132 , pp. 145-147
    • Gudmundsson, G.1    Sogaard, I.2
  • 20
    • 1342302822 scopus 로고    scopus 로고
    • Usefulness of acellular dermal graft as a dural substitute in experimental model
    • S. Islam, K. Ogane, H. Ohkuma, S. Suzuki Usefulness of acellular dermal graft as a dural substitute in experimental model Surg Neurol 61 2004 297 303
    • (2004) Surg Neurol , vol.61 , pp. 297-303
    • Islam, S.1    Ogane, K.2    Ohkuma, H.3    Suzuki, S.4
  • 21
    • 69549103393 scopus 로고    scopus 로고
    • Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery
    • B.T. Jankowitz, D.S. Atteberry, P.C. Gerszten, P. Karausky, B.C. Cheng, R. Faugh, W.C. Welch Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery Eur Spine J 18 2009 1169 1174
    • (2009) Eur Spine J , vol.18 , pp. 1169-1174
    • Jankowitz, B.T.1    Atteberry, D.S.2    Gerszten, P.C.3    Karausky, P.4    Cheng, B.C.5    Faugh, R.6    Welch, W.C.7
  • 22
    • 0242558053 scopus 로고    scopus 로고
    • Evaluation of the use of BioGlue in neurosurgical procedures
    • A. Kumar, N.F. Maartens, A.H. Kaye Evaluation of the use of BioGlue in neurosurgical procedures J Clin Neurosci 10 2003 661 664
    • (2003) J Clin Neurosci , vol.10 , pp. 661-664
    • Kumar, A.1    Maartens, N.F.2    Kaye, A.H.3
  • 23
    • 0025605666 scopus 로고
    • Comparative study of lyophilized human dura mater and lyophilized bovine pericardium as dural substitutes in neurosurgery
    • A. Laun, J.C. Tonn, C. Jerusalem Comparative study of lyophilized human dura mater and lyophilized bovine pericardium as dural substitutes in neurosurgery Acta Neurochir (Wien) 107 1990 16 21
    • (1990) Acta Neurochir (Wien) , vol.107 , pp. 16-21
    • Laun, A.1    Tonn, J.C.2    Jerusalem, C.3
  • 24
    • 0034974974 scopus 로고    scopus 로고
    • Prevention and management of cerebrospinal fluid fistula after transtemporal skull base surgery
    • J.P. Leonetti, D. Anderson, S. Marzo, G. Moynihan Prevention and management of cerebrospinal fluid fistula after transtemporal skull base surgery Skull Base 11 2001 87 92
    • (2001) Skull Base , vol.11 , pp. 87-92
    • Leonetti, J.P.1    Anderson, D.2    Marzo, S.3    Moynihan, G.4
  • 25
    • 1342332063 scopus 로고    scopus 로고
    • Evaluation of a novel propylene oxide-treated collagen material as a dural substitute
    • C.O. Maher, R.E. Anderson, R.L. McClelland, M.J. Link Evaluation of a novel propylene oxide-treated collagen material as a dural substitute J Neurosurg 99 2003 1070 1076
    • (2003) J Neurosurg , vol.99 , pp. 1070-1076
    • Maher, C.O.1    Anderson, R.E.2    McClelland, R.L.3    Link, M.J.4
  • 26
    • 33845504462 scopus 로고    scopus 로고
    • Effectiveness and handling characteristics of a three-layer polymer dura substitute: A prospective multicenter clinical study
    • A.M. Messing-Jünger, J. Ibáñez, F. Calbucci, M. Choux, G. Lena, I. Mohsenipour, F. Van Calenbergh Effectiveness and handling characteristics of a three-layer polymer dura substitute: a prospective multicenter clinical study J Neurosurg 105 2006 853 858
    • (2006) J Neurosurg , vol.105 , pp. 853-858
    • Messing-Jünger, A.M.1    Ibáñez, J.2    Calbucci, F.3    Choux, M.4    Lena, G.5    Mohsenipour, I.6    Van Calenbergh, F.7
  • 27
    • 0028900020 scopus 로고
    • A clinicopathological study of collagen sponge as a dural graft in neurosurgery
    • P.K. Narotam, J.R. van Dellen, K.D. Bhoola A clinicopathological study of collagen sponge as a dural graft in neurosurgery J Neurosurg 82 1995 406 412
    • (1995) J Neurosurg , vol.82 , pp. 406-412
    • Narotam, P.K.1    Van Dellen, J.R.2    Bhoola, K.D.3
  • 28
    • 0021267861 scopus 로고
    • Use of porcine dermis as a dural substitute in 72 patients
    • P. O'Neill, A.E. Booth Use of porcine dermis as a dural substitute in 72 patients J Neurosurg 61 1984 351 354
    • (1984) J Neurosurg , vol.61 , pp. 351-354
    • O'Neill, P.1    Booth, A.E.2
  • 29
    • 0030870945 scopus 로고    scopus 로고
    • Detailed evaluation of 2959 allogeneic and xenogeneic dense connective tissue grafts (fascia lata, pericardium, and dura mater) used in the course of 20 years for duraplasty in neurosurgery
    • J. Parízek, P. Mericka, Z. Husek, P. Suba, J. Spacek, S. Nemecek, J. Nemecková, M. Sercl, P. Eliás Detailed evaluation of 2959 allogeneic and xenogeneic dense connective tissue grafts (fascia lata, pericardium, and dura mater) used in the course of 20 years for duraplasty in neurosurgery Acta Neurochir (Wien) 139 1997 827 838
    • (1997) Acta Neurochir (Wien) , vol.139 , pp. 827-838
    • Parízek, J.1    Mericka, P.2    Husek, Z.3    Suba, P.4    Spacek, J.5    Nemecek, S.6    Nemecková, J.7    Sercl, M.8    Eliás, P.9
  • 31
    • 0008369442 scopus 로고
    • Meningocerebral adhesions A histological study of the results of cerebral incisions and cranioplasty
    • W. Penfield Meningocerebral adhesions A histological study of the results of cerebral incisions and cranioplasty Surg Gynecol Obstet 39 1924 803 810
    • (1924) Surg Gynecol Obstet , vol.39 , pp. 803-810
    • Penfield, W.1
  • 33
    • 0025247184 scopus 로고
    • Biologically inert synthetic dural substitutes Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer
    • D.E. Sakas, K. Charnvises, L.F. Borges, N.T. Zervas Biologically inert synthetic dural substitutes Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer J Neurosurg 73 1990 936 941
    • (1990) J Neurosurg , vol.73 , pp. 936-941
    • Sakas, D.E.1    Charnvises, K.2    Borges, L.F.3    Zervas, N.T.4
  • 35
    • 34548203865 scopus 로고    scopus 로고
    • Duraplasty in the posterior fossa using a boat-shaped sheet of expanded polytetrafluoroethylene
    • S. Shimizu, H. Koizumi, M. Kurita, S. Utsuki, H. Oka, K. Fujii Duraplasty in the posterior fossa using a boat-shaped sheet of expanded polytetrafluoroethylene Neurol Med Chir (Tokyo) 47 2007 379 381
    • (2007) Neurol Med Chir (Tokyo) , vol.47 , pp. 379-381
    • Shimizu, S.1    Koizumi, H.2    Kurita, M.3    Utsuki, S.4    Oka, H.5    Fujii, K.6
  • 36
    • 0025271637 scopus 로고
    • The use of fibrin glue in intracranial procedures: Preliminary results
    • D.H. Sierra, A.J. Nissen, J. Welch The use of fibrin glue in intracranial procedures: preliminary results Laryngoscope 100 1990 360 363
    • (1990) Laryngoscope , vol.100 , pp. 360-363
    • Sierra, D.H.1    Nissen, A.J.2    Welch, J.3
  • 37
    • 0036123629 scopus 로고    scopus 로고
    • Evaluation of the healing process after dural reconstruction achieved using a free fascial graft
    • E. Tachibana, K. Saito, K. Fukuta, J. Yoshida Evaluation of the healing process after dural reconstruction achieved using a free fascial graft J Neurosurg 96 2002 280 286
    • (2002) J Neurosurg , vol.96 , pp. 280-286
    • Tachibana, E.1    Saito, K.2    Fukuta, K.3    Yoshida, J.4
  • 38
    • 56849102250 scopus 로고    scopus 로고
    • Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery
    • K.D. Than, C.J. Baird, A. Olivi Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery Neurosurgery 63 1 Suppl 1 2008 ONS182 ONS187
    • (2008) Neurosurgery , vol.63 , Issue.1 SUPPL. 1
    • Than, K.D.1    Baird, C.J.2    Olivi, A.3
  • 39
    • 0032984391 scopus 로고    scopus 로고
    • The effect of fibrin adhesive (Tisseel) on interbody allograft fusion: An experimental study with cats
    • M. Turgut, M. Erkus, N. Tavus The effect of fibrin adhesive (Tisseel) on interbody allograft fusion: an experimental study with cats Acta Neurochir (Wien) 141 1999 273 278
    • (1999) Acta Neurochir (Wien) , vol.141 , pp. 273-278
    • Turgut, M.1    Erkus, M.2    Tavus, N.3
  • 41
    • 0031050051 scopus 로고    scopus 로고
    • Duraplasty with freeze-dried cadaveric dura versus occipital pericranium for Chiari type i malformation: Comparative study
    • V. Vanaclocha, N. Saiz-Sapena Duraplasty with freeze-dried cadaveric dura versus occipital pericranium for Chiari type I malformation: comparative study Acta Neurochir (Wien) 139 1997 112 119
    • (1997) Acta Neurochir (Wien) , vol.139 , pp. 112-119
    • Vanaclocha, V.1    Saiz-Sapena, N.2
  • 44
    • 0031466690 scopus 로고    scopus 로고
    • Effectiveness of fibrin glue for preventing postoperative extradural fluid leakage
    • T. Yoshimoto, Y. Sawamura, K. Houkin, H. Abe Effectiveness of fibrin glue for preventing postoperative extradural fluid leakage Neurol Med Chir (Tokyo) 37 1997 886 890
    • (1997) Neurol Med Chir (Tokyo) , vol.37 , pp. 886-890
    • Yoshimoto, T.1    Sawamura, Y.2    Houkin, K.3    Abe, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.