메뉴 건너뛰기




Volumn 80, Issue , 2013, Pages 180-185

Comparison of Limulus amebocyte lysate test methods for endotoxin measurement in protein solutions

Author keywords

Biologics; Endotoxin; LAL; Lipopolysaccharide; Protein solutions

Indexed keywords

ENDOTOXIN; LIPOPOLYSACCHARIDE; PROTEIN; REAGENT;

EID: 84876337364     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2013.03.011     Document Type: Article
Times cited : (30)

References (29)
  • 3
    • 0003590614 scopus 로고
    • Guideline for Validation of Limulus Amebocyte Lysate Test as an End-Product Endotoxin Test for Human and Animal Parenteral Drugs, Biological Products, and Medical Devices
    • US-FDA
    • US-FDA, Guideline for Validation of Limulus Amebocyte Lysate Test as an End-Product Endotoxin Test for Human and Animal Parenteral Drugs, Biological Products, and Medical Devices, 1987.
    • (1987)
  • 4
    • 84888284998 scopus 로고    scopus 로고
    • United States Pharmacopeia, Bacterial Endotoxin Test Chapter <85>, USP 28
    • United States Pharmacopeia, Bacterial Endotoxin Test Chapter <85>, USP 28, 2009.
    • (2009)
  • 5
    • 0025735356 scopus 로고
    • Limulus factor C. An endotoxin-sensitive serine protease zymogen with a mosaic structure of complement-like, epidermal growth factor-like, and lectin-like domains
    • Muta T., Miyata T., Misumi Y., Tokunaga F., Nakamura T., Toh Y., Ikehara Y., Iwanaga S. Limulus factor C. An endotoxin-sensitive serine protease zymogen with a mosaic structure of complement-like, epidermal growth factor-like, and lectin-like domains. J. Biol. Chem. 1991, 266:6554-6561.
    • (1991) J. Biol. Chem. , vol.266 , pp. 6554-6561
    • Muta, T.1    Miyata, T.2    Misumi, Y.3    Tokunaga, F.4    Nakamura, T.5    Toh, Y.6    Ikehara, Y.7    Iwanaga, S.8
  • 6
    • 0028305321 scopus 로고
    • Protein purification: aspects of processes for pharmaceutical products
    • Berthold W., Walter J. Protein purification: aspects of processes for pharmaceutical products. Biologicals 1994, 22:135-150.
    • (1994) Biologicals , vol.22 , pp. 135-150
    • Berthold, W.1    Walter, J.2
  • 7
    • 0033991321 scopus 로고    scopus 로고
    • Endotoxin removal from protein solutions
    • Petsch D., Anspach F.B. Endotoxin removal from protein solutions. J. Biotechnol. 2000, 76:97-119.
    • (2000) J. Biotechnol. , vol.76 , pp. 97-119
    • Petsch, D.1    Anspach, F.B.2
  • 8
    • 0022658657 scopus 로고
    • Endotoxin detection and elimination in biotechnology
    • Sharma S.K. Endotoxin detection and elimination in biotechnology. Biotechnol. Appl. Biochem. 1986, 8:5-22.
    • (1986) Biotechnol. Appl. Biochem. , vol.8 , pp. 5-22
    • Sharma, S.K.1
  • 12
    • 0026658378 scopus 로고
    • Variability in the LAL test: comparison of three kinetic methods for the testing of pharmaceutical products
    • McCullough K.Z., Weidner-Loeven C. Variability in the LAL test: comparison of three kinetic methods for the testing of pharmaceutical products. J. Parenter. Sci. Technol. 1992, 46:69-72.
    • (1992) J. Parenter. Sci. Technol. , vol.46 , pp. 69-72
    • McCullough, K.Z.1    Weidner-Loeven, C.2
  • 13
    • 84888274518 scopus 로고    scopus 로고
    • Variability in the bacterial endotoxins test or LAL (Limulus Amebocyte Lysate) Test
    • Kumar H. Variability in the bacterial endotoxins test or LAL (Limulus Amebocyte Lysate) Test. EndoSafe Times 2006, 12:1-7.
    • (2006) EndoSafe Times , vol.12 , pp. 1-7
    • Kumar, H.1
  • 14
    • 0035006598 scopus 로고    scopus 로고
    • Adsorption of endotoxins on glass in the presence of cationic proteins
    • Yokota H., Kiyonaga H., Kaniwa H., Shibanuma T. Adsorption of endotoxins on glass in the presence of cationic proteins. J. Pharm. Biomed. Anal. 2001, 25:1001-1007.
    • (2001) J. Pharm. Biomed. Anal. , vol.25 , pp. 1001-1007
    • Yokota, H.1    Kiyonaga, H.2    Kaniwa, H.3    Shibanuma, T.4
  • 17
    • 84876336021 scopus 로고    scopus 로고
    • Protocol for sample storage temperatures
    • LabNote
    • LabNote, Protocol for sample storage temperatures, EndoSafe Times, 9 (2003) 3-5.
    • (2003) EndoSafe Times , vol.9 , pp. 3-5
  • 18
    • 78650302442 scopus 로고    scopus 로고
    • Saline and buffers minimize the action of interfering factors in the bacterial endotoxins test
    • Fujita Y., Tokunaga T., Kataoka H. Saline and buffers minimize the action of interfering factors in the bacterial endotoxins test. Anal. Biochem. 2011, 409:46-53.
    • (2011) Anal. Biochem. , vol.409 , pp. 46-53
    • Fujita, Y.1    Tokunaga, T.2    Kataoka, H.3
  • 20
    • 0029038440 scopus 로고
    • The importance of the quality of water in Limulus Amebocyte Lysate tests
    • Duner K.I. The importance of the quality of water in Limulus Amebocyte Lysate tests. PDA J. Pharm. Sci. Technol. 1995, 49:119-121.
    • (1995) PDA J. Pharm. Sci. Technol. , vol.49 , pp. 119-121
    • Duner, K.I.1
  • 22
    • 0035426586 scopus 로고    scopus 로고
    • A new era in pyrogen testing
    • Ding J.L., Ho B. A new era in pyrogen testing. Trends Biotechnol. 2001, 19:277-281.
    • (2001) Trends Biotechnol. , vol.19 , pp. 277-281
    • Ding, J.L.1    Ho, B.2
  • 25
    • 0026095934 scopus 로고
    • Sensitivity of Limulus amebocyte lysate (LAL) to LAL-reactive glucans
    • Roslansky P.F., Novitsky T.J. Sensitivity of Limulus amebocyte lysate (LAL) to LAL-reactive glucans. J. Clin. Microbiol. 1991, 29:2477-2483.
    • (1991) J. Clin. Microbiol. , vol.29 , pp. 2477-2483
    • Roslansky, P.F.1    Novitsky, T.J.2
  • 26
    • 0030744865 scopus 로고    scopus 로고
    • The impact of non-endotoxin LAL-reactive materials on Limulus amebocyte lysate analyses
    • Cooper J.F., Weary M.E., Jordan F.T. The impact of non-endotoxin LAL-reactive materials on Limulus amebocyte lysate analyses. PDA J. Pharm. Sci. Technol. 1997, 51:2-6.
    • (1997) PDA J. Pharm. Sci. Technol. , vol.51 , pp. 2-6
    • Cooper, J.F.1    Weary, M.E.2    Jordan, F.T.3
  • 29
    • 0345241187 scopus 로고    scopus 로고
    • Detection of lipopolysaccharide in hemoglobin-vesicles by Limulus amebocyte lysate test with kinetic-turbidimetric gel clotting analysis and pretreatment of surfactant
    • Sakai H., Hisamoto S., Fukutomi I., Sou K., Takeoka S., Tsuchida E. Detection of lipopolysaccharide in hemoglobin-vesicles by Limulus amebocyte lysate test with kinetic-turbidimetric gel clotting analysis and pretreatment of surfactant. J. Pharm. Sci. 2004, 93:310-321.
    • (2004) J. Pharm. Sci. , vol.93 , pp. 310-321
    • Sakai, H.1    Hisamoto, S.2    Fukutomi, I.3    Sou, K.4    Takeoka, S.5    Tsuchida, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.