메뉴 건너뛰기




Volumn 44, Issue 4, 2013, Pages 1169-1171

Accuracy of diffusion-weighted imaging in the diagnosis of stroke in patients with suspected cerebral infarct

Author keywords

Diagnosis; Diffusion weighted imaging; Stroke

Indexed keywords

AGED; ARTICLE; BRAIN INFARCTION; CEREBROVASCULAR ACCIDENT; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIAGNOSTIC ACCURACY; DIFFUSION WEIGHTED IMAGING; EMERGENCY CARE; EMERGENCY WARD; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; NEUROIMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; STROKE PATIENT;

EID: 84876291221     PISSN: 00392499     EISSN: 15244628     Source Type: Journal    
DOI: 10.1161/STROKEAHA.111.000527     Document Type: Article
Times cited : (40)

References (10)
  • 2
    • 0030906785 scopus 로고    scopus 로고
    • Clinical utility of diffusion-weighted magnetic resonance imaging in the assessment of ischemic stroke
    • Lutsep HL, Albers GW, DeCrespigny A, Kamat GN, Marks MP, Moseley ME. Clinical utility of diffusion-weighted magnetic resonance imaging in the assessment of ischemic stroke. Ann Neurol. 1997;41:574-580.
    • (1997) Ann Neurol. , vol.41 , pp. 574-580
    • Lutsep, H.L.1    Albers, G.W.2    Decrespigny, A.3    Kamat, G.N.4    Marks, M.P.5    Moseley, M.E.6
  • 5
    • 46249130596 scopus 로고    scopus 로고
    • When to expect negative diffusion-weighted images in stroke and transient ischemic attack
    • VISION Study Group
    • Sylaja PN, Coutts SB, Krol A, Hill MD, Demchuk AM; VISION Study Group. When to expect negative diffusion-weighted images in stroke and transient ischemic attack. Stroke. 2008;39:1898-1900.
    • (2008) Stroke. , vol.39 , pp. 1898-1900
    • Sylaja, P.N.1    Coutts, S.B.2    Krol, A.3    Hill, M.D.4    Demchuk, A.M.5
  • 6
    • 0344766121 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging: Diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset
    • González RG, Schaefer PW, Buonanno FS, Schwamm LH, Budzik RF, Rordorf G, et al. Diffusion-weighted MR imaging: diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset. Radiology. 1999;210:155-162.
    • (1999) Radiology. , vol.210 , pp. 155-162
    • González, R.G.1    Schaefer, P.W.2    Buonanno, F.S.3    Schwamm, L.H.4    Budzik, R.F.5    Rordorf, G.6
  • 8
    • 77954875156 scopus 로고    scopus 로고
    • Additional information given to a multimodal imaging stroke protocol by transcranial Doppler ultrasound in the emergency room: A prospective observational study
    • Brunser AM, Lavados PM, Cárcamo DA, Hoppe A, Olavarría V, Diaz V, et al. Additional information given to a multimodal imaging stroke protocol by transcranial Doppler ultrasound in the emergency room: a prospective observational study. Cerebrovasc Dis. 2010;30: 260-266.
    • (2010) Cerebrovasc Dis. , vol.30 , pp. 260-266
    • Brunser, A.M.1    Lavados, P.M.2    Cárcamo, D.A.3    Hoppe, A.4    Olavarría, V.5    Diaz, V.6
  • 9
    • 79958288886 scopus 로고    scopus 로고
    • Safety and outcomes of intravenous thrombolysis in stroke mimics: A 6-year, single-care center study and a pooled analysis of reported series
    • Tsivgoulis G, Alexandrov AV, Chang J, Sharma VK, Hoover SL, Lao AY, et al. Safety and outcomes of intravenous thrombolysis in stroke mimics: a 6-year, single-care center study and a pooled analysis of reported series. Stroke. 2011;42:1771-1774.
    • (2011) Stroke. , vol.42 , pp. 1771-1774
    • Tsivgoulis, G.1    Alexandrov, A.V.2    Chang, J.3    Sharma, V.K.4    Hoover, S.L.5    Lao, A.Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.