메뉴 건너뛰기




Volumn 32, Issue 5, 2013, Pages

Anterior segment optical coherence tomography versus ultrasound pachymetry to measure corneal thickness in endothelial keratoplasty donor corneas

Author keywords

corneal thickness; Descemet stripping automated endothelial keratoplasty; optical coherence tomography; ultrasound pachymetry

Indexed keywords

ARTICLE; CORNEA THICKNESS; CORNEA TRANSPLANTATION; ECHOGRAPHY; ENDOTHELIAL KERATOPLASTY; EYE PHOTOGRAPHY; EYEBANK; HUMAN; MEASUREMENT; OPTICAL COHERENCE TOMOGRAPHY; PACHYMETRY; PRIORITY JOURNAL;

EID: 84876251387     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31827c0b5b     Document Type: Article
Times cited : (8)

References (29)
  • 1
    • 62149120694 scopus 로고    scopus 로고
    • Refractive change after descemet stripping automated endothelial keratoplasty surgery and its correlation with graft thickness and diameter
    • Jun B, Kuo AN, Afshari NA, et al. Refractive change after descemet stripping automated endothelial keratoplasty surgery and its correlation with graft thickness and diameter. Cornea. 2009;28:19-23.
    • (2009) Cornea , vol.28 , pp. 19-23
    • Jun, B.1    Kuo, A.N.2    Afshari, N.A.3
  • 2
    • 40949107729 scopus 로고    scopus 로고
    • Multivariate model of refractive shift in Descemet-stripping automated endothelial keratoplasty
    • DOI 10.1016/j.jcrs.2007.11.045, PII S088633500800062X
    • Dupps WJ Jr, Qian Y, Meisler DM. Multivariate model of refractive shift in Descemet-stripping automated endothelial keratoplasty. J Cataract Refract Surg. 2008;34:578-84. (Pubitemid 351417611)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.4 , pp. 578-584
    • Dupps Jr., W.J.1    Qian, Y.2    Meisler, D.M.3
  • 3
    • 84876295396 scopus 로고    scopus 로고
    • Relationship of visual acuity and lamellar thickness in Descemet's stripping automated endothelial keratoplasty
    • [epub ahead of print]
    • Woodard MW, Raoof-Daneshvar D, Mian S, et al. Relationship of visual acuity and lamellar thickness in Descemet's stripping automated endothelial keratoplasty. Cornea. 2012 [epub ahead of print].
    • (2012) Cornea
    • Woodard, M.W.1    Raoof-Daneshvar, D.2    Mian, S.3
  • 4
    • 67349154933 scopus 로고    scopus 로고
    • Corneal deturgescence after Descemet stripping automated endothelial keratoplasty evaluated by Visante anterior segment optical coherence tomography
    • e1
    • Di Pascuale MA, Prasher P, Schlecte C, et al. Corneal deturgescence after Descemet stripping automated endothelial keratoplasty evaluated by Visante anterior segment optical coherence tomography. Am J Ophthalmol. 2009;148:32-37.e1.
    • (2009) Am J Ophthalmol , vol.148 , pp. 32-37
    • Di Pascuale, M.A.1    Prasher, P.2    Schlecte, C.3
  • 5
    • 67149139339 scopus 로고    scopus 로고
    • Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography
    • Nieuwendaal CP, van Velthoven ME, Biallosterski C, et al. Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography. Cornea. 2009;28:298-303.
    • (2009) Cornea , vol.28 , pp. 298-303
    • Nieuwendaal, C.P.1    Van Velthoven, M.E.2    Biallosterski, C.3
  • 6
    • 77957273179 scopus 로고    scopus 로고
    • Host and graft thickness after descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy
    • e2
    • Ahmed KA, McLaren JW, Baratz KH, et al. Host and graft thickness after descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy. Am J Ophthalmol. 2010;150:490-497.e2.
    • (2010) Am J Ophthalmol , vol.150 , pp. 490-497
    • Ahmed, K.A.1    McLaren, J.W.2    Baratz, K.H.3
  • 7
    • 84863393714 scopus 로고    scopus 로고
    • Impact of graft thickness on visual acuity after descemet's stripping endothelial keratoplasty
    • Shinton AJ, Tsatsos M, Konstantopoulos A, et al. Impact of graft thickness on visual acuity after descemet's stripping endothelial keratoplasty. Br J Ophthalmol. 2012;96:246-249.
    • (2012) Br J Ophthalmol , vol.96 , pp. 246-249
    • Shinton, A.J.1    Tsatsos, M.2    Konstantopoulos, A.3
  • 8
    • 66749168957 scopus 로고    scopus 로고
    • Changes in donor corneal lenticule thickness after descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas
    • Pogorelov P, Cursiefen C, Bachmann BO, et al. Changes in donor corneal lenticule thickness after descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas. Br J Ophthalmol. 2009;93:825-829.
    • (2009) Br J Ophthalmol , vol.93 , pp. 825-829
    • Pogorelov, P.1    Cursiefen, C.2    Bachmann, B.O.3
  • 9
    • 79952989175 scopus 로고    scopus 로고
    • Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty
    • Neff KD, Biber JM, Holland EJ. Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty. Cornea. 2011;30:388-391.
    • (2011) Cornea , vol.30 , pp. 388-391
    • Neff, K.D.1    Biber, J.M.2    Holland, E.J.3
  • 10
    • 49849087772 scopus 로고    scopus 로고
    • In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty
    • Brown JS, Wang D, Li X, et al. In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty. Cornea. 2008;27:802-810.
    • (2008) Cornea , vol.27 , pp. 802-810
    • Brown, J.S.1    Wang, D.2    Li, X.3
  • 11
    • 84855848655 scopus 로고    scopus 로고
    • Measurements of microkeratome cuts in donor corneas with ultrasound and optical coherence tomography
    • Tang M, Ward D, Ramos JL, et al. Measurements of microkeratome cuts in donor corneas with ultrasound and optical coherence tomography. Cornea. 2012;31:145-149.
    • (2012) Cornea , vol.31 , pp. 145-149
    • Tang, M.1    Ward, D.2    Ramos, J.L.3
  • 12
    • 79952988115 scopus 로고    scopus 로고
    • Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using anterior segment optical coherence tomography
    • Amato D, Lombardo M, Oddone F, et al. Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using anterior segment optical coherence tomography. Br J Ophthalmol. 2011;95:580-584.
    • (2011) Br J Ophthalmol , vol.95 , pp. 580-584
    • Amato, D.1    Lombardo, M.2    Oddone, F.3
  • 14
    • 0035171269 scopus 로고    scopus 로고
    • Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    • DOI 10.1097/00003226-200101000-00010
    • Bechmann M, Thiel MJ, Neubauer AS, et al. Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry. Cornea. 2001;20:50-54. (Pubitemid 32038155)
    • (2001) Cornea , vol.20 , Issue.1 , pp. 50-54
    • Bechmann, M.1    Thiel, M.J.2    Neubauer, A.S.3    Ullrich, S.4    Ludwig, K.5    Kenyon, K.R.6    Ulbig, M.W.7
  • 15
    • 84864410148 scopus 로고    scopus 로고
    • Measurement of central corneal thickness by high-resolution Scheimpflug imaging Fourier-domain optical coherence tomography and ultrasound pachymetry
    • Chen S, Huang J, Wen D, et al. Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry. Acta Ophthalmol. 2010;90:449-455.
    • (2010) Acta Ophthalmol , vol.90 , pp. 449-455
    • Chen, S.1    Huang, J.2    Wen, D.3
  • 16
    • 79957725817 scopus 로고    scopus 로고
    • Central corneal thickness measurements with Fourier-domain optical coherence tomography versus ultrasonic pachymetry and rotating Scheimpflug camera
    • Ishibazawa A, Igarashi S, Hanada K, et al. Central corneal thickness measurements with Fourier-domain optical coherence tomography versus ultrasonic pachymetry and rotating Scheimpflug camera. Cornea. 2011; 30:615-619.
    • (2011) Cornea , vol.30 , pp. 615-619
    • Ishibazawa, A.1    Igarashi, S.2    Hanada, K.3
  • 17
    • 80051552593 scopus 로고    scopus 로고
    • A comprehensive comparison of central corneal thickness measurement
    • Huang J, Pesudovs K, Yu A, et al. A comprehensive comparison of central corneal thickness measurement. Optom Vis Sci. 2011;88:940-949.
    • (2011) Optom Vis Sci , vol.88 , pp. 940-949
    • Huang, J.1    Pesudovs, K.2    Yu, A.3
  • 18
    • 42149165577 scopus 로고    scopus 로고
    • Central corneal thickness measurements by ultrasound, orbscan II, and visante OCT after LASIK for myopia
    • Cheng AC, Rao SK, Lau S, et al. Central corneal thickness measurements by ultrasound, Orbscan II, and Visante OCT after LASIK for myopia. J Refract Surg. 2008;24:361-365. (Pubitemid 351544002)
    • (2008) Journal of Refractive Surgery , vol.24 , Issue.4 , pp. 361-365
    • Cheng, A.C.K.1    Rao, S.K.2    Lau, S.3    Leung, C.K.S.4    Lam, D.S.C.5
  • 19
    • 0035171269 scopus 로고    scopus 로고
    • Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    • DOI 10.1097/00003226-200101000-00010
    • Bechmann M, Thiel MJ, Neubauer AS, et al. Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry. Cornea. 2001;20:50-54. (Pubitemid 32038155)
    • (2001) Cornea , vol.20 , Issue.1 , pp. 50-54
    • Bechmann, M.1    Thiel, M.J.2    Neubauer, A.S.3    Ullrich, S.4    Ludwig, K.5    Kenyon, K.R.6    Ulbig, M.W.7
  • 20
    • 77952483677 scopus 로고    scopus 로고
    • Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry
    • Grewal DS, Brar GS, Grewal SP. Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry. J Cataract Refract Surg. 2010;36: 954-964.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 954-964
    • Grewal, D.S.1    Brar, G.S.2    Grewal, S.P.3
  • 21
    • 67249126267 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
    • Prospero Ponce CM, Rocha KM, Smith SD, et al. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes. J Cataract Refract Surg. 2009; 35:1055-1062.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1055-1062
    • Prospero Ponce, C.M.1    Rocha, K.M.2    Smith, S.D.3
  • 23
    • 34248590339 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    • DOI 10.1016/j.ajo.2007.01.050, PII S0002939407001213
    • Zhao PS, Wong TY, Wong WL, et al. Comparison of central corneal thickness measurements by Visante anterior segment optical coherence tomography with ultrasound pachymetry. Am J Ophthalmol. 2007;143: 1047-1049. (Pubitemid 46764644)
    • (2007) American Journal of Ophthalmology , vol.143 , Issue.6 , pp. 1047-1049
    • Zhao, P.S.1    Wong, T.Y.2    Wong, W.-L.3    Saw, S.-M.4    Aung, T.5
  • 24
    • 38349182519 scopus 로고    scopus 로고
    • Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
    • Kim HY, Budenz DL, Lee PS, et al. Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry. Am J Ophthalmol. 2008;145:228-232.
    • (2008) Am J Ophthalmol , vol.145 , pp. 228-232
    • Kim, H.Y.1    Budenz, D.L.2    Lee, P.S.3
  • 25
    • 79955677661 scopus 로고    scopus 로고
    • Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry
    • Beutelspacher SC, Serbecic N, Scheuerle AF. Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry. Eur J Ophthalmol. 2011;21: 132-137.
    • (2011) Eur J Ophthalmol , vol.21 , pp. 132-137
    • Beutelspacher, S.C.1    Serbecic, N.2    Scheuerle, A.F.3
  • 26
    • 65249094349 scopus 로고    scopus 로고
    • Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy
    • Schneider M, Borgulya G, Seres A, et al. Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy. Eur J Ophthalmol. 2009;19:180-187.
    • (2009) Eur J Ophthalmol , vol.19 , pp. 180-187
    • Schneider, M.1    Borgulya, G.2    Seres, A.3
  • 27
    • 67349112996 scopus 로고    scopus 로고
    • Effect of corneal hydration on ultrasound velocity and backscatter
    • Silverman RH, Patel MS, Gal O, et al. Effect of corneal hydration on ultrasound velocity and backscatter. Ultrasound Med Biol. 2009;35: 839-846.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 839-846
    • Silverman, R.H.1    Patel, M.S.2    Gal, O.3
  • 28
    • 0019215480 scopus 로고
    • On the optical measurement of corneal thickness. I. Optical principle and sources of error
    • Olsen T, Nielsen CB, Ehlers N. On the optical measurement of a corneal thickness. I. Optical principle and sources of error. Acta Ophthalmol (Copenh). 1980;58:760-766. (Pubitemid 11238172)
    • (1980) Acta Ophthalmologica , vol.58 , Issue.5 , pp. 760-766
    • Olsen, T.1    Nielsen, C.B.2    Ehlers, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.