메뉴 건너뛰기




Volumn 35, Issue 4, 2013, Pages 433-440

The use of near-infrared light for safe and effective visualization of subsurface blood vessels to facilitate blood withdrawal in children

Author keywords

Artery; Imaging; Near infrared; NIR; Pediatrics; Peripheral catheterization; Vein; Venipuncture

Indexed keywords

ARTERY; NEAR INFRARED; NIR; PERIPHERAL CATHETERIZATION; VEIN; VENIPUNCTURE;

EID: 84876139259     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2012.06.007     Document Type: Article
Times cited : (59)

References (27)
  • 1
    • 56149126961 scopus 로고    scopus 로고
    • Optimizing the management of peripheral venous access pain in children: evidence, impact, and implementation
    • Zempsky W.T. Optimizing the management of peripheral venous access pain in children: evidence, impact, and implementation. Pediatrics 2008, 122(Suppl. 3):S121-S124.
    • (2008) Pediatrics , vol.122 , Issue.SUPPL. 3
    • Zempsky, W.T.1
  • 2
    • 40949149496 scopus 로고    scopus 로고
    • Derivation of the DIVA score: a clinical prediction rule for the identification of children with difficult intravenous access
    • Yen K., Riegert A., Gorelick M.H. Derivation of the DIVA score: a clinical prediction rule for the identification of children with difficult intravenous access. Pediatr Emerg Care 2008, 24:143-147.
    • (2008) Pediatr Emerg Care , vol.24 , pp. 143-147
    • Yen, K.1    Riegert, A.2    Gorelick, M.H.3
  • 3
    • 66249096324 scopus 로고    scopus 로고
    • Randomized controlled trial of ultrasound-guided peripheral intravenous catheter placement versus traditional techniques in difficult-access pediatric patients
    • Doniger S.J., Ishimine P., Fox J.C., Kanegaye J.T. Randomized controlled trial of ultrasound-guided peripheral intravenous catheter placement versus traditional techniques in difficult-access pediatric patients. Pediatr Emerg Care 2009, 25:154-159.
    • (2009) Pediatr Emerg Care , vol.25 , pp. 154-159
    • Doniger, S.J.1    Ishimine, P.2    Fox, J.C.3    Kanegaye, J.T.4
  • 6
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jobsis F.F. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977, 198:1264-1267.
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jobsis, F.F.1
  • 7
    • 34548255974 scopus 로고    scopus 로고
    • Feasibility of multi-spectral imaging system to provide enhanced demarcation for skin tumor resection
    • de Roode R., Noordmans H.J., Verdaasdonk R.M. Feasibility of multi-spectral imaging system to provide enhanced demarcation for skin tumor resection. Proc SPIE 6424 2007.
    • (2007) Proc SPIE 6424
    • de Roode, R.1    Noordmans, H.J.2    Verdaasdonk, R.M.3
  • 8
    • 84966607889 scopus 로고
    • Light scattering in Intralipid-10% in the wavelength range of 400-1100nm
    • van Staveren H.J., Moes C.J., van M.J., Prahl S.A., van Gemert M.J. Light scattering in Intralipid-10% in the wavelength range of 400-1100nm. Appl Opt 1991, 30:4507-4514.
    • (1991) Appl Opt , vol.30 , pp. 4507-4514
    • van Staveren, H.J.1    Moes, C.J.2    van, M.J.3    Prahl, S.A.4    van Gemert, M.J.5
  • 9
    • 0028001446 scopus 로고
    • A phantom for the testing and calibration of near infra-red spectrometers
    • Firbank M., Delpy D.T. A phantom for the testing and calibration of near infra-red spectrometers. Phys Med Biol 1994, 39:1509-1513.
    • (1994) Phys Med Biol , vol.39 , pp. 1509-1513
    • Firbank, M.1    Delpy, D.T.2
  • 12
    • 0016992234 scopus 로고
    • Increase in the information content of the image of the surface veins by using a television infrascope
    • Ontikova N.M., Iaroslavtsev D.A., Lirman A.V. Increase in the information content of the image of the surface veins by using a television infrascope. Med Tekh 1976, 20-22.
    • (1976) Med Tekh , pp. 20-22
    • Ontikova, N.M.1    Iaroslavtsev, D.A.2    Lirman, A.V.3
  • 14
    • 0037058573 scopus 로고    scopus 로고
    • Near-infrared finger vein patterns for personal identification
    • Kono M., Ueki H., Umemura S. Near-infrared finger vein patterns for personal identification. Appl Opt 2002, 41:7429-7436.
    • (2002) Appl Opt , vol.41 , pp. 7429-7436
    • Kono, M.1    Ueki, H.2    Umemura, S.3
  • 15
    • 33751099806 scopus 로고    scopus 로고
    • Remote non-invasive stereoscopic imaging of blood vessels: first in vivo results of a new multispectral contrast enhancement technology
    • Wieringa F.P., Mastik F., Cate F.J., Neumann H.A., van der Steen A.F. Remote non-invasive stereoscopic imaging of blood vessels: first in vivo results of a new multispectral contrast enhancement technology. Ann Biomed Eng 2006, 34:1870-1878.
    • (2006) Ann Biomed Eng , vol.34 , pp. 1870-1878
    • Wieringa, F.P.1    Mastik, F.2    Cate, F.J.3    Neumann, H.A.4    van der Steen, A.F.5
  • 16
    • 77950889917 scopus 로고    scopus 로고
    • Utilization of infrared trans-illumination as an aid for peripheral arterial access
    • [abstract]
    • Dunn M.R., Conrad S. Utilization of infrared trans-illumination as an aid for peripheral arterial access. Acad Emerg Med 2005, 12(5 (Suppl. 1)):34-35. [abstract].
    • (2005) Acad Emerg Med , vol.12 , Issue.5 SUPPL. 1 , pp. 34-35
    • Dunn, M.R.1    Conrad, S.2
  • 17
    • 33746910542 scopus 로고    scopus 로고
    • Vein imaging: a new method of near infrared imaging, where a processed image is projected onto the skin for the enhancement of vein treatment
    • Miyake R.K., Zeman H.D., Duarte F.H., Kikuchi R., Ramacciotti E., Lovhoiden G., et al. Vein imaging: a new method of near infrared imaging, where a processed image is projected onto the skin for the enhancement of vein treatment. Dermatol Surg 2006, 32:1031-1038.
    • (2006) Dermatol Surg , vol.32 , pp. 1031-1038
    • Miyake, R.K.1    Zeman, H.D.2    Duarte, F.H.3    Kikuchi, R.4    Ramacciotti, E.5    Lovhoiden, G.6
  • 18
    • 58149398741 scopus 로고    scopus 로고
    • Tutorial on diffuse light transport
    • Jacques S.L., Pogue B.W. Tutorial on diffuse light transport. J Biomed Opt 2008, 13:041302.
    • (2008) J Biomed Opt , vol.13 , pp. 041302
    • Jacques, S.L.1    Pogue, B.W.2
  • 19
    • 80052756867 scopus 로고    scopus 로고
    • VeinViewer-assisted Intravenous catheter placement in a pediatric emergency department
    • Chapman L.L., Sullivan B., Pacheco A.L., Draleau C.P., Becker B.M. VeinViewer-assisted Intravenous catheter placement in a pediatric emergency department. Acad Emerg Med 2011, 18(9):966-971.
    • (2011) Acad Emerg Med , vol.18 , Issue.9 , pp. 966-971
    • Chapman, L.L.1    Sullivan, B.2    Pacheco, A.L.3    Draleau, C.P.4    Becker, B.M.5
  • 20
    • 78751591091 scopus 로고    scopus 로고
    • Efficacy of a near-infrared light device in pediatric intravenous cannulation: a randomized controlled trial
    • Perry A.M., Caviness A.C., Hsu D.C. Efficacy of a near-infrared light device in pediatric intravenous cannulation: a randomized controlled trial. Pediatr Emerg Care 2011, 27(1):5-10.
    • (2011) Pediatr Emerg Care , vol.27 , Issue.1 , pp. 5-10
    • Perry, A.M.1    Caviness, A.C.2    Hsu, D.C.3
  • 21
    • 79952114732 scopus 로고    scopus 로고
    • A biomedical device to improve pediatric vascular access success
    • Hess H.A. A biomedical device to improve pediatric vascular access success. Pediatr Nurs. 2010, 36(5):259-263.
    • (2010) Pediatr Nurs. , vol.36 , Issue.5 , pp. 259-263
    • Hess, H.A.1
  • 22
    • 0023910298 scopus 로고
    • Light dosimetry in optical phantoms and in tissues: I. Multiple flux and transport theory
    • Star W.M., Marijnissen J.P., van Gemert M.J. Light dosimetry in optical phantoms and in tissues: I. Multiple flux and transport theory. Phys Med Biol 1988, 33:437-454.
    • (1988) Phys Med Biol , vol.33 , pp. 437-454
    • Star, W.M.1    Marijnissen, J.P.2    van Gemert, M.J.3
  • 23
    • 84876108886 scopus 로고    scopus 로고
    • [retrieved 20.8.10]
    • Jacques, S.L., [retrieved 20.8.10]. http://omlc.ogi.edu/news/jan98/skinoptics.html.
    • Jacques, S.L.1
  • 24
    • 84876143183 scopus 로고    scopus 로고
    • [retrieved 20.8.10].
    • Prahl, S.A. [retrieved 20.8.10]. http://omlc.ogi.edu/spectra/hemoglobin/summary.html.
    • Prahl, S.A.1
  • 25
    • 0032714683 scopus 로고    scopus 로고
    • Optical properties of circulating human blood in the wavelength range 400-2500nm
    • Roggan A., Friebel M., Dorschel K., Hahn A., Muller G. Optical properties of circulating human blood in the wavelength range 400-2500nm. J Biomed Opt 1999, 4:36-46.
    • (1999) J Biomed Opt , vol.4 , pp. 36-46
    • Roggan, A.1    Friebel, M.2    Dorschel, K.3    Hahn, A.4    Muller, G.5
  • 26
    • 23044449569 scopus 로고    scopus 로고
    • Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000nm
    • Bashkatov A.N., Genina E.A., Kochubey V.I., Tuchin V.V. Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000nm. J Phys 2005, 38:2543-2555.
    • (2005) J Phys , vol.38 , pp. 2543-2555
    • Bashkatov, A.N.1    Genina, E.A.2    Kochubey, V.I.3    Tuchin, V.V.4
  • 27
    • 0031711208 scopus 로고    scopus 로고
    • Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique
    • Simpson C.R., Kohl M., Essenpreis M., Cope M. Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys Med Biol 1998, 43:2465-2478.
    • (1998) Phys Med Biol , vol.43 , pp. 2465-2478
    • Simpson, C.R.1    Kohl, M.2    Essenpreis, M.3    Cope, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.