메뉴 건너뛰기




Volumn 68, Issue 5, 2013, Pages

Combining low tube voltage and iterative reconstruction for contrast-enhanced CT imaging of the chest - Initial clinical experience

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BODY MASS; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTRAST TO NOISE RATIO; DOSE RESPONSE; ELECTRIC POTENTIAL; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; LOW ENERGY RADIATION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE REDUCTION; RADIATION EXPOSURE; SIGNAL NOISE RATIO; THORAX PAIN; THORAX RADIOGRAPHY; THORAX WALL;

EID: 84876119274     PISSN: 00099260     EISSN: 1365229X     Source Type: Journal    
DOI: 10.1016/j.crad.2012.12.009     Document Type: Article
Times cited : (28)

References (19)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D.J. Brenner, and E.J. Hall Computed tomography: an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 40049109570 scopus 로고    scopus 로고
    • International commission on radiation protection. Managing patient dose in multidetector computed tomography (MDCT). ICRP Publication 102
    • J. Valentin International commission on radiation protection. Managing patient dose in multidetector computed tomography (MDCT). ICRP Publication 102 Ann ICRP 37 2007 1 79
    • (2007) Ann ICRP , vol.37 , pp. 1-79
    • Valentin, J.1
  • 3
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT-radiation dose in CT
    • M.F. McNitt-Gray AAPM/RSNA physics tutorial for residents: topics in CT-radiation dose in CT RadioGraphics 22 2002 1541 1553
    • (2002) RadioGraphics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 4
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • M.K. Kalra, M.M. Maher, and T.L. Toth Techniques and applications of automatic tube current modulation for CT Radiology 233 2004 649 657
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 5
    • 33644824157 scopus 로고    scopus 로고
    • Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation
    • J. Campbell, M.K. Kalra, and S. Rizzo Scanning beyond anatomic limits of the thorax in chest CT: findings, radiation dose, and automatic tube current modulation AJR Am J Roentgenol 185 2005 1525 1530
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 1525-1530
    • Campbell, J.1    Kalra, M.K.2    Rizzo, S.3
  • 6
    • 35148852590 scopus 로고    scopus 로고
    • Principles of CT and CT technology
    • DOI 10.2967/jnmt.107.042978
    • L.W. Goldman Principles of CT and CT technology J Nucl Med Technol 35 2007 115 128 (Pubitemid 47549619)
    • (2007) Journal of Nuclear Medicine Technology , vol.35 , Issue.3 , pp. 115-128
    • Goldman, L.W.1
  • 7
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • A.K. Hara, R.G. Paden, and A.C. Silva Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study AJR Am J Roentgenol 193 2009 764 771
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3
  • 8
    • 78649700320 scopus 로고    scopus 로고
    • A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction
    • J. Leipsic, G. Nguyen, and J. Brown A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction AJR Am J Roentgenol 195 2010 1095 1099
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1095-1099
    • Leipsic, J.1    Nguyen, G.2    Brown, J.3
  • 9
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): Image quality of low-dose CT examinations in 80 patients
    • F. Pontana, J. Pagniez, and T. Flohr Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients Eur Radiol 21 2011 636 643
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 11
    • 1642389455 scopus 로고    scopus 로고
    • Low-Kilovoltage Multi-Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose
    • DOI 10.1148/radiol.2311030191
    • A.B. Sigal-Chinqualbre, R. Hennequin, and H.T. Abada Low-kilovoltage multidetector row chest CT in adults: feasibility and effect on image quality and iodine dose Radiology 231 2004 169 174 (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 12
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low dose pulmonary computed tomography angiography: Comparison of 100- and 80-Kvp protocols
    • Z. Szucs-Farkas, L. Kurmann, and T. Strautz Patient exposure and image quality of low dose pulmonary computed tomography angiography: comparison of 100- and 80-Kvp protocols Invest Radiol 43 2008 871 876
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 13
    • 80052962265 scopus 로고    scopus 로고
    • Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    • X.H. Hu, X.F. Ding, and R.Z. Wu Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space Clin Radiol 66 2011 1023 1029
    • (2011) Clin Radiol , vol.66 , pp. 1023-1029
    • Hu, X.H.1    Ding, X.F.2    Wu, R.Z.3
  • 14
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • D. Marin, R.C. Nelson, and S.T. Schindera Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience Radiology 254 2010 145 153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 15
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
    • J. Leipsic, T.M. Labounty, and B. Heilbron Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography AJR Am J Roentgenol 195 2010 649 654
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 16
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • J. Leipsic, T.M. Labounty, and B. Heilbron Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study AJR Am J Roentgenol 195 2010 655 660
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 17
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • A.C. Silva, H.J. Lawder, and A. Hara Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm AJR Am J Roentgenol 194 2010 191 199
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3
  • 18
    • 80051517687 scopus 로고    scopus 로고
    • Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography
    • Y. Funama, T. Katsuyuki, and D. Utsunomiya Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography J Comput Assist Tomogr 35 2011 480 485
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 480-485
    • Funama, Y.1    Katsuyuki, T.2    Utsunomiya, D.3
  • 19
    • 84861526057 scopus 로고    scopus 로고
    • Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT
    • D. Utsunomiya, W.G. Weigold, and G. Weissman Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT Eur Radiol 22 2012 1287 1294
    • (2012) Eur Radiol , vol.22 , pp. 1287-1294
    • Utsunomiya, D.1    Weigold, W.G.2    Weissman, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.