메뉴 건너뛰기




Volumn 34, Issue 5 SPL, 2013, Pages 466-471

Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device

Author keywords

[No Author keywords available]

Indexed keywords

ACINETOBACTER; ARTICLE; BACTERIAL COLONIZATION; CLINICAL ARTICLE; CLOSTRIDIUM DIFFICILE; CLOSTRIDIUM DIFFICILE INFECTION; COHORT ANALYSIS; COLONY FORMING UNIT; DISINFECTION; HUMAN; INTERVENTION STUDY; MICROBIOLOGY; PATHOGENESIS; PROSPECTIVE STUDY; STATISTICAL ANALYSIS; TERTIARY HEALTH CARE; ULTRAVIOLET C RADIATION; VANCOMYCIN RESISTANT ENTEROCOCCUS; WASTE MANAGEMENT;

EID: 84876077099     PISSN: 0899823X     EISSN: None     Source Type: Journal    
DOI: 10.1086/670215     Document Type: Article
Times cited : (102)

References (25)
  • 1
    • 53549094653 scopus 로고    scopus 로고
    • Recommendations for metrics for multidrug-resistant organisms in healthcare settings: SHEA/HICPAC position paper
    • Cohen AL, Calfee D, Fridkin SK, et al. Recommendations for metrics for multidrug-resistant organisms in healthcare settings: SHEA/HICPAC position paper. Infect Control Hosp Epidemiol 2008;29(10):901-913.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , Issue.10 , pp. 901-913
    • Cohen, A.L.1    Calfee, D.2    Fridkin, S.K.3
  • 2
    • 0033976370 scopus 로고    scopus 로고
    • Survival of enterococci and staphylococci on hospital fabrics and plastic
    • Neely AN, Maley MP. Survival of enterococci and staphylococci on hospital fabrics and plastic. J Clin Microbiol 2000;38(2):724-726.
    • (2000) J Clin Microbiol , vol.38 , Issue.2 , pp. 724-726
    • Neely, A.N.1    Maley, M.P.2
  • 3
    • 0031132010 scopus 로고    scopus 로고
    • Role of environmental contamination in the transmission of vancomycin-resistant enterococci
    • Weber DJ, Rutala WA. Role of environmental contamination in the transmission of vancomycin-resistant enterococci. Infect Control Hosp Epidemiol 1997;18(5):306-309.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , Issue.5 , pp. 306-309
    • Weber, D.J.1    Rutala, W.A.2
  • 4
    • 0033004465 scopus 로고    scopus 로고
    • Survival of Acinetobacter baumannii on bed rails during an outbreak and during sporadic cases
    • Catalano M, Quelle LS, Jeric PE, Di Martino A, Maimone SM. Survival of Acinetobacter baumannii on bed rails during an outbreak and during sporadic cases. J Hosp Infect 1999;42(1):27-35.
    • (1999) J Hosp Infect , vol.42 , Issue.1 , pp. 27-35
    • Catalano, M.1    Quelle, L.S.2    Jeric, P.E.3    di Martino, A.4    Maimone, S.M.5
  • 5
    • 0031808598 scopus 로고    scopus 로고
    • Survival of Acinetobacter baumannii on dry surfaces: Comparison of outbreak and sporadic isolates
    • Jawad A, Seifert H, Snelling AM, Heritage J, Hawkey PM. Survival of Acinetobacter baumannii on dry surfaces: comparison of outbreak and sporadic isolates. J Clin Microbiol 1998;36(7): 1938-1941.
    • (1998) J Clin Microbiol , vol.36 , Issue.7 , pp. 1938-1941
    • Jawad, A.1    Seifert, H.2    Snelling, A.M.3    Heritage, J.4    Hawkey, P.M.5
  • 6
    • 0025368565 scopus 로고
    • The survival of Acinetobacter calcoaceticus inoculated on fingertips and on formica
    • Musa EK, Desai N, Casewell MW. The survival of Acinetobacter calcoaceticus inoculated on fingertips and on formica. J Hosp Infect 1990;15(3):219-227.
    • (1990) J Hosp Infect , vol.15 , Issue.3 , pp. 219-227
    • Musa, E.K.1    Desai, N.2    Casewell, M.W.3
  • 7
    • 0019497353 scopus 로고
    • Isolation of Clostridium difficile from the environment and contacts of patients with antibiotic-associated colitis
    • Kim KH, Fekety R, Batts DH, et al. Isolation of Clostridium difficile from the environment and contacts of patients with antibiotic-associated colitis. J Infect Dis 1981;143(1):42-50.
    • (1981) J Infect Dis , vol.143 , Issue.1 , pp. 42-50
    • Kim, K.H.1    Fekety, R.2    Batts, D.H.3
  • 8
    • 79955130786 scopus 로고    scopus 로고
    • Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants
    • Datta R, Platt R, Yokoe DS, Huang SS. Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants. Arch Intern Med 2011;171(6):491-494.
    • (2011) Arch Intern Med , vol.171 , Issue.6 , pp. 491-494
    • Datta, R.1    Platt, R.2    Yokoe, D.S.3    Huang, S.S.4
  • 9
    • 39749120490 scopus 로고    scopus 로고
    • Prior environmental contamination increases the risk of acquisition of vancomycinresistant enterococci
    • Drees M, Snydman DR, Schmid CH, et al. Prior environmental contamination increases the risk of acquisition of vancomycinresistant enterococci. Clin Infect Dis 2008;46(5):678-685.
    • (2008) Clin Infect Dis , vol.46 , Issue.5 , pp. 678-685
    • Drees, M.1    Snydman, D.R.2    Schmid, C.H.3
  • 10
    • 33749574575 scopus 로고    scopus 로고
    • Risk of acquiring antibiotic-resistant bacteria from prior room occupants
    • Huang SS, Datta R, Platt R. Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med 2006; 166(18):1945-1951.
    • (2006) Arch Intern Med , vol.166 , Issue.18 , pp. 1945-1951
    • Huang, S.S.1    Datta, R.2    Platt, R.3
  • 11
    • 79952411060 scopus 로고    scopus 로고
    • Evaluation of hospital room assignment and acquisition of Clostridium difficile infection
    • Shaughnessy MK, Micielli RL, DePestel DD, et al. Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol 2011;32(3):201-206.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , Issue.3 , pp. 201-206
    • Shaughnessy, M.K.1    Micielli, R.L.2    DePestel, D.D.3
  • 12
    • 40649129661 scopus 로고    scopus 로고
    • Evaluating the thoroughness of environmental cleaning in hospitals
    • Carling PC. Evaluating the thoroughness of environmental cleaning in hospitals. J Hosp Infect 2008;68(3):273-274.
    • (2008) J Hosp Infect , vol.68 , Issue.3 , pp. 273-274
    • Carling, P.C.1
  • 13
    • 39449113970 scopus 로고    scopus 로고
    • Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals
    • Carling PC, Parry MF, Von Beheren SM. Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals. Infect Control Hosp Epidemiol 2008;29(1):1-7.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , Issue.1 , pp. 1-7
    • Carling, P.C.1    Parry, M.F.2    von Beheren, S.M.3
  • 14
    • 37749005066 scopus 로고    scopus 로고
    • Intensive care unit environmental cleaning: An evaluation in sixteen hospitals using a novel assessment tool
    • Carling PC, Von Beheren S, Kim P, Woods C. Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool. J Hosp Infect 2008;68(1):39-44.
    • (2008) J Hosp Infect , vol.68 , Issue.1 , pp. 39-44
    • Carling, P.C.1    von Beheren, S.2    Kim, P.3    Woods, C.4
  • 15
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010;10:197.
    • (2010) BMC Infect Dis , vol.10 , pp. 197
    • Nerandzic, M.M.1    Cadnum, J.L.2    Pultz, M.J.3    Donskey, C.J.4
  • 17
    • 33744733251 scopus 로고    scopus 로고
    • Spores of Bacillus subtilis: Their resistance to and killing by radiation, heat and chemicals
    • Setlow P. Spores of Bacillus subtilis: their resistance to and killing by radiation, heat and chemicals. J Appl Microbiol 2006;101(3): 514-525.
    • (2006) J Appl Microbiol , vol.101 , Issue.3 , pp. 514-525
    • Setlow, P.1
  • 18
    • 79960701617 scopus 로고    scopus 로고
    • Terminal decontamination of patient rooms using an automated mobile UV light unit
    • Boyce JM, Havill NL, Moore BA. Terminal decontamination of patient rooms using an automated mobile UV light unit. Infect Control Hosp Epidemiol 2011;32(8):737-742.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , Issue.8 , pp. 737-742
    • Boyce, J.M.1    Havill, N.L.2    Moore, B.A.3
  • 20
    • 36148984113 scopus 로고    scopus 로고
    • Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with ultraviolet C light
    • Rastogi VK, Wallace L, Smith LS. Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with ultraviolet C light. Mil Med 2007;172(11):1166-1169.
    • (2007) Mil Med , vol.172 , Issue.11 , pp. 1166-1169
    • Rastogi, V.K.1    Wallace, L.2    Smith, L.S.3
  • 21
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010;10:197.
    • (2010) BMC Infect Dis , vol.10 , pp. 197
    • Nerandzic, M.M.1    Cadnum, J.L.2    Pultz, M.J.3    Donskey, C.J.4
  • 22
    • 63249125724 scopus 로고    scopus 로고
    • Can hospital computers be disinfected using a hand-held UV light source?
    • Sweeney CP, Dancer SJ. Can hospital computers be disinfected using a hand-held UV light source? J Hosp Infect 2009;72(1): 92-94.
    • (2009) J Hosp Infect , vol.72 , Issue.1 , pp. 92-94
    • Sweeney, C.P.1    Dancer, S.J.2
  • 23
    • 75949113756 scopus 로고    scopus 로고
    • Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers
    • Kac G, Podglajen I, Si-Mohamed A, Rodi A, Grataloup C, Meyer G. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol 2010;31(2):165-170.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , Issue.2 , pp. 165-170
    • Kac, G.1    Podglajen, I.2    Si-Mohamed, A.3    Rodi, A.4    Grataloup, C.5    Meyer, G.6
  • 24
    • 84859342352 scopus 로고    scopus 로고
    • Environmental decontamination with ultraviolet radiation to prevent recurrent Clostridium difficile infection in 2 roommates in a long-term care facility
    • Sitzlar B, Vajravelu RK, Jury L, Donskey CJ, Jump RL. Environmental decontamination with ultraviolet radiation to prevent recurrent Clostridium difficile infection in 2 roommates in a long-term care facility. Infect Control Hosp Epidemiol 2012;33(5): 534-536.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , Issue.5 , pp. 534-536
    • Sitzlar, B.1    Vajravelu, R.K.2    Jury, L.3    Donskey, C.J.4    Jump, R.L.5
  • 25
    • 84861014016 scopus 로고    scopus 로고
    • Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens
    • Nerandzic MM, Cadnum JL, Eckart KE, Donskey CJ. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis 2012;12:120.
    • (2012) BMC Infect Dis , vol.12 , pp. 120
    • Nerandzic, M.M.1    Cadnum, J.L.2    Eckart, K.E.3    Donskey, C.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.