메뉴 건너뛰기




Volumn 39 IFMBE, Issue , 2013, Pages 426-429

Calibration of pulse wave transit time method in blood pressure measurement based on the Korotkoff sound delay time

Author keywords

blood pressure; calibration; Korotkoff sound delay time; noninvasive measurement; pulse wave transit time

Indexed keywords

ARTERIAL PRESSURES; CALIBRATION METHOD; CONTINUOUS BLOOD PRESSURE MONITORING; DELAY TIME; MEAN ARTERIAL PRESSURE; NONINVASIVE MEASUREMENTS; PULSE WAVE TRANSIT TIME; TECHNICAL REALIZATION;

EID: 84876051894     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-29305-4_113     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 2
    • 0032897226 scopus 로고    scopus 로고
    • Pulse transit time: An appraisal of potential clinical applications
    • DOI 10.1136/thx.54.5.452
    • Smith R, Argod J, Pepin J et al (1999) Pulse transit time: an appraisal of potential clinical applications. Thorax 54:452-457 DOI 10.1136/thx.54.5.452
    • (1999) Thorax , vol.54 , pp. 452-457
    • Smith, R.1    Argod, J.2    Pepin, J.3
  • 3
    • 0028789504 scopus 로고
    • Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea
    • Pitson D, Sandell A, Hout R et al (1995) Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. Eur Respir J 8:1669-74
    • (1995) Eur Respir J , vol.8 , pp. 1669-1674
    • Pitson, D.1    Sandell, A.2    Hout, R.3
  • 5
    • 84876061441 scopus 로고    scopus 로고
    • Continuous noninvasive blood pressure measurement using the pulse wave transit time
    • Xiang H, Yu M (2005) Continuous noninvasive blood pressure measurement using the pulse wave transit time. Chinese Medical Equipment Journal 26:5-6
    • (2005) Chinese Medical Equipment Journal , vol.26 , pp. 5-6
    • Xiang, H.1    Yu, M.2
  • 6
    • 0033497261 scopus 로고    scopus 로고
    • The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs
    • Ochiai R (1999) The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs. Journal of Clinical Monitoring and Computing 15:493-501
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , pp. 493-501
    • Ochiai, R.1
  • 7
    • 0002920728 scopus 로고
    • Measurement of pulse wave velocity
    • Bazzett H, Dfeyer N (1922) Measurement of pulse wave velocity. Am. J. Physiol. 63:94-115
    • (1922) Am. J. Physiol. , vol.63 , pp. 94-115
    • Bazzett, H.1    Dfeyer, N.2
  • 8
    • 0007629021 scopus 로고
    • A method of using induced waves to study pressure propagation in human arteries
    • Lansdown M (1957) A method of using induced waves to study pressure propagation in human arteries. Circ.Res, 5:594-601
    • (1957) Circ.Res , vol.5 , pp. 594-601
    • Lansdown, M.1
  • 9
    • 0034281859 scopus 로고    scopus 로고
    • Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    • Chen W, Kobayashi T, Ichikawa S et al (2000) Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med Biol Eng Comput38:569-574
    • (2000) Med Biol Eng Comput , vol.38 , pp. 569-574
    • Chen, W.1    Kobayashi, T.2    Ichikawa, S.3
  • 10
    • 84856025786 scopus 로고    scopus 로고
    • Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time
    • DOI: 10.1097/MBP.0b013e32834f710b
    • Xiang H, Liu Y, Li Y et al (2011) Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time. Blood Press Monit DOI: 10.1097/MBP.0b013e32834f710b
    • (2011) Blood Press Monit
    • Xiang, H.1    Liu, Y.2    Li, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.