메뉴 건너뛰기




Volumn , Issue , 2012, Pages

Robust distance protection of mid-point shunt compensated transmission line

Author keywords

Distance protection; FACTS; Shunt compensation

Indexed keywords

DISTANCE PROTECTION; ELECTROMAGNETIC TRANSIENT PROGRAM; FACTS; FLEXIBLE AC TRANSMISSION SYSTEM; POWER TRANSFER CAPABILITY; SHUNT COMPENSATION; STATIC SYNCHRONOUS COMPENSATOR; SYNCHRONIZED MEASUREMENT;

EID: 84876040763     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PowerI.2012.6479485     Document Type: Conference Paper
Times cited : (10)

References (11)
  • 4
    • 0033692106 scopus 로고    scopus 로고
    • Adaptive relay setting for flexible AC transmission systems (FACTS)
    • Jan.
    • P.K Dash, A. K Pradhan, Ganapati Panda, and A. C. Liew, "Adaptive Relay Setting for Flexible AC Transmission Systems (FACTS)", IEEE Tran. Power Delivery, Vol 15, pp. 3843, Jan. 2000.
    • (2000) IEEE Tran. Power Delivery , vol.15 , pp. 3843
    • Dash, P.K.1    Pradhan, A.K.2    Panda, G.3    Liew, A.C.4
  • 5
    • 0036529608 scopus 로고    scopus 로고
    • Operation of impedance protection relay with the STATCOM
    • April
    • Khalil El-Arroudi, G. Joos, D.T. McGillis, "Operation of Impedance Protection Relay With the STATCOM", IEEE Tram. Power Delivery, Vol. 17, pp.381-387. April 2002.
    • (2002) IEEE Tram. Power Delivery , vol.17 , pp. 381-387
    • El-Arroudi, K.1    Joos, G.2    McGillis, D.T.3
  • 6
    • 50249174377 scopus 로고    scopus 로고
    • Measured impedance by distance relay in presence of SVC on transmission line
    • 2006, Paris, France November
    • A. Kazemi, S. Jamali and H. Shateri, "Measured Impedance by Distance Relay in Presence of SVC on Transmission Line," IEEE Industrial Electronics, IECON 2006, Paris, France, pp.2214-2219, November 2006.
    • (2006) IEEE Industrial Electronics, IECON , pp. 2214-2219
    • Kazemi, A.1    Jamali, S.2    Shateri, H.3
  • 10
    • 42549159362 scopus 로고    scopus 로고
    • Mitigation of adverse effects of midpoint shunt-FACTS compensated transmission lines on distance protection schemes
    • Albasri F.A., Sidhu T.S., Varma R.K., "Mitigation of Adverse Effects of Midpoint Shunt-FACTS Compensated Transmission Lines on Distance Protection Schemes," Power Engineering Society General Meeting Rep. pp 1-8, 2007.
    • (2007) Power Engineering Society General Meeting Rep , pp. 1-8
    • Albasri, F.A.1    Sidhu, T.S.2    Varma, R.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.