메뉴 건너뛰기




Volumn 29, Issue 4, 2013, Pages 266-272

Inferior intrastromal corneal ring segments in paracentral keratoconus with no coincident topographic and coma axis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; HUMAN; IMPLANTATION; INTRASTROMAL CORNEAL RING SEGMENT; KERATOCONUS; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; PUPIL; REFRACTION ERROR; REFRACTION INDEX; VISUAL ACUITY;

EID: 84875972518     PISSN: 1081597X     EISSN: 19382391     Source Type: Journal    
DOI: 10.3928/1081597X-20130318-06     Document Type: Article
Times cited : (46)

References (16)
  • 1
    • 33745216716 scopus 로고    scopus 로고
    • Corneal higher order aberrations: A method to grade keratoconus
    • Alio JL, Shabayek MH. Corneal higher order aberrations: a method to grade keratoconus. J Refract Surg. 2006;22:539-445.
    • (2006) J Refract Surg. , vol.22 , pp. 539-445
    • Alio, J.L.1    Shabayek, M.H.2
  • 2
    • 33751309178 scopus 로고    scopus 로고
    • Intacs insertion with the femtosecond laser for the management of keratoconus one-year results
    • Ertan A, Kamburoglu, Bahadir M. Intacs insertion with the femtosecond laser for the management of keratoconus one-year results. J Cataract Refract Surg. 2006;32:2039-2042.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2039-2042
    • Ertan, A.1    Kamburoglu, B.M.2
  • 3
    • 49449117329 scopus 로고    scopus 로고
    • Intacs implantation using a femtosecond laser for management of keratoconus: Comparison of 306 cases in different stages
    • Ertan A, Kamburoglu G. Intacs implantation using a femtosecond laser for management of keratoconus: comparison of 306 cases in different stages. J Cataract Refract Surg. 2008;34:1521-1526.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1521-1526
    • Ertan, A.1    Kamburoglu, G.2
  • 4
    • 43049091156 scopus 로고    scopus 로고
    • One-year results of intrastromal corneal ring segment implantation (Keraring) using femtosecond laser in patients with keratoconus
    • Coskunseven E, Kymionis GD, Tsiklis NS, et al. One-year results of intrastromal corneal ring segment implantation (Keraring) using femtosecond laser in patients with keratoconus. Am J Ophthalmol. 2008;145:775-779.
    • (2008) Am J Ophthalmol , vol.145 , pp. 775-779
    • Coskunseven, E.1    Kymionis, G.D.2    Tsiklis, N.S.3
  • 5
    • 34548250484 scopus 로고    scopus 로고
    • Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction
    • Shabayek MH, Alio JL. Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction. Ophthalmology. 2007;114:1643-1652.
    • (2007) Ophthalmology , vol.114 , pp. 1643-1652
    • Shabayek, M.H.1    Alio, J.L.2
  • 9
    • 33744831467 scopus 로고    scopus 로고
    • European clinical evaluation: Use of Intacs for the treatment of keratoconus
    • Colin J. European clinical evaluation: use of Intacs for the treatment of keratoconus. J Cataract Refract Surg. 2006;32:747-755.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 747-755
    • Colin, J.1
  • 11
    • 84865262796 scopus 로고    scopus 로고
    • Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis
    • Alfonso JF, Lisa C, Merayo-Lloves J, Fernandez-Vega Cueto L, Montes-Mico R. Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis. J Cataract Refract Surg. 2012;38:1576-1582.
    • (2012) J Cataract Refract Surg , vol.38 , pp. 1576-1582
    • Alfonso, J.F.1    Lisa, C.2    Merayo-Lloves, J.3    Fernandez-Vega Cueto, L.4    Montes-Mico, R.5
  • 12
    • 0028885963 scopus 로고
    • Comparison of methods for detecting keratoconus using videokeratography
    • Maeda N, Klyce SD, Smolek MK. Comparison of methods for detecting keratoconus using videokeratography. Arch Ophthalmol. 1995;113:870-874.
    • (1995) Arch Ophthalmol , vol.113 , pp. 870-874
    • Maeda, N.1    Klyce, S.D.2    Smolek, M.K.3
  • 13
    • 0031929336 scopus 로고    scopus 로고
    • Accuracy of ultrasonic pachymetry and videokeratography in detecting keratoconus
    • Rabinowitz YS, Rasheed K, Yang H, Elashoff J. Accuracy of ultrasonic pachymetry and videokeratography in detecting keratoconus. J Cataract Refract Surg. 1998;24:196-201.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 196-201
    • Rabinowitz, Y.S.1    Rasheed, K.2    Yang, H.3    Elashoff, J.4
  • 14
    • 33746038909 scopus 로고    scopus 로고
    • Corneal elevation indices in normal and keratoconic eyes
    • Fam HB, Lim KL. Corneal elevation indices in normal and keratoconic eyes. J Cataract Refract Surg. 2006;32:1281-1287.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1281-1287
    • Fam, H.B.1    Lim, K.L.2
  • 15
    • 0035140259 scopus 로고    scopus 로고
    • Power vector analysis of the optical outcome of refractive surgery
    • Thibos LN, Horner D. Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg. 2001;27:80-85.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 80-85
    • Thibos, L.N.1    Horner, D.2
  • 16
    • 0013883782 scopus 로고
    • Modification of refraction by means of intracorneal inclusion
    • Barraquer JI. Modification of refraction by means of intracorneal inclusion. Int Ophthalmol Clin. 1966;6:53-78.
    • (1966) Int Ophthalmol Clin , vol.6 , pp. 53-78
    • Barraquer, J.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.