메뉴 건너뛰기




Volumn 38, Issue 5, 2013, Pages 550-562

Comparative evaluation of uniplex, nested, semi-nested, multiplex and nested multiplex PCR methods in the identification of microbial etiology of clinically Suspected Infectious Endophthalmitis

Author keywords

DNA sequence based identification; Identification of un cultured bacterial etiology; Infectious endophthalmitis; PCR based identification of microbial etiology; Polymerase chain reaction

Indexed keywords

RNA 16S; RNA 28S;

EID: 84875884069     PISSN: 02713683     EISSN: 14602202     Source Type: Journal    
DOI: 10.3109/02713683.2013.772205     Document Type: Article
Times cited : (25)

References (18)
  • 2
    • 0028839594 scopus 로고
    • Results of the Endophthalmitis Vitrectomy Study: A randomized trial of immediate vitrectomy and intravenous antibiotics for the treatment of postoperative bacterial endophthalmitis
    • Endophthalmitis Vitrectomy Study (EVS) Group.
    • Endophthalmitis Vitrectomy Study (EVS) Group. Results of the Endophthalmitis Vitrectomy Study: A randomized trial of immediate vitrectomy and intravenous antibiotics for the treatment of postoperative bacterial endophthalmitis. Arch Ophthalmol 1995; 113:1479-1496.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1479-1496
  • 3
    • 65349130681 scopus 로고    scopus 로고
    • Microbiological profile of culture-proven cases of exogenous and endogenous endophthalmitis: A 10-years retrospective study
    • Ramakrishnan R, Bharathi MJ, Shivkumar C, Mittal S, Meenakshi R, Khadeer MA, et al. Microbiological profile of culture-proven cases of exogenous and endogenous endophthalmitis: A 10-years retrospective study. Eye 2009;23:945-956.
    • (2009) Eye , vol.23 , pp. 945-956
    • Ramakrishnan, R.1    Bharathi, M.J.2    Shivkumar, C.3    Mittal, S.4    Meenakshi, R.5    Khadeer, M.A.6
  • 4
    • 0028290053 scopus 로고
    • The diagnosis of delayed postoperative endophthalmitis by polymerase chain reaction of bacterial DNA in vitreous samples
    • Hykin PG, Tobal K, McIntyre G, Matheson MM, Towler HM, Lightman SL. The diagnosis of delayed postoperative endophthalmitis by polymerase chain reaction of bacterial DNA in vitreous samples. J Med Microbiol 1994;40:408-415.
    • (1994) J Med Microbiol , vol.40 , pp. 408-415
    • Hykin, P.G.1    Tobal, K.2    McIntyre, G.3    Matheson, M.M.4    Towler, H.M.5    Lightman, S.L.6
  • 5
    • 0031686110 scopus 로고    scopus 로고
    • Polymerase chain reaction in the diagnosis of bacterial endophthalmitis
    • Therese KL, Anand AR, Madhavan HN. Polymerase chain reaction in the diagnosis of bacterial endophthalmitis. Br J Ophthalmol 1998;82:1078-1082.
    • (1998) Br J Ophthalmol , vol.82 , pp. 1078-1082
    • Therese, K.L.1    Anand, A.R.2    Madhavan, H.N.3
  • 6
    • 0035147531 scopus 로고    scopus 로고
    • Use of polymerase chain reaction in the diagnosis of fungal endophthalmitis
    • Anand A, Madhavan H, Neelam V, Lily T. Use of polymerase chain reaction in the diagnosis of fungal endophthalmitis. Ophthalmology 2001;108:326-330.
    • (2001) Ophthalmology , vol.108 , pp. 326-330
    • Anand, A.1    Madhavan, H.2    Neelam, V.3    Lily, T.4
  • 7
    • 33746642090 scopus 로고    scopus 로고
    • Development and application of multiplex polymerase chain reaction for the etiological diagnosis of infectious endophthalmitis
    • Bagyalakshmi R, Madhavan HN, Therese KL. Development and application of multiplex polymerase chain reaction for the etiological diagnosis of infectious endophthalmitis. J Postgrad Med 2006;52:179-182.
    • (2006) J Postgrad Med , vol.52 , pp. 179-182
    • Bagyalakshmi, R.1    Madhavan, H.N.2    Therese, K.L.3
  • 12
    • 0034525815 scopus 로고    scopus 로고
    • Use of polymerase chain reaction (PCR) and DNA probe hybridization to determine the gram reaction of the infecting bacterium in the intra-ocular fluids of patients with endophthalmitis
    • Anand AR, Madhavan HN, Therese KL. Use of polymerase chain reaction (PCR) and DNA probe hybridization to determine the gram reaction of the infecting bacterium in the intra-ocular fluids of patients with endophthalmitis. J Infection 2000;41:221-226.
    • (2000) J Infection , vol.41 , pp. 221-226
    • Anand, A.R.1    Madhavan, H.N.2    Therese, K.L.3
  • 13
    • 49649118347 scopus 로고    scopus 로고
    • Laboratory diagnosis of endophthalmitis: Comparison of microbiology and molecular methods in the European society of cataract & refractive surgeons multicenter study and susceptibility testing
    • Seal D, Reischl U, Behr A, Ferrer C, Alio J, Koerner RJ, et al. Laboratory diagnosis of endophthalmitis: Comparison of microbiology and molecular methods in the European society of cataract & refractive surgeons multicenter study and susceptibility testing. J Cataract Refract Surg 2008; 34:1439-1450.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1439-1450
    • Seal, D.1    Reischl, U.2    Behr, A.3    Ferrer, C.4    Alio, J.5    Koerner, R.J.6
  • 14
    • 44649130927 scopus 로고    scopus 로고
    • Eubacterial PCR for bacterial detection and identification in 100 acute postcataract surgery endophthalmitis
    • Chiquet C, Cornut PL, Benito Y, Thuret G, Maurin M, Lafontaine PO, et al. Eubacterial PCR for bacterial detection and identification in 100 acute postcataract surgery endophthalmitis. IOVS 2008;49:1971-1978.
    • (2008) IOVS , vol.49 , pp. 1971-1978
    • Chiquet, C.1    Cornut, P.L.2    Benito, Y.3    Thuret, G.4    Maurin, M.5    Lafontaine, P.O.6
  • 15
    • 0034021772 scopus 로고    scopus 로고
    • Detection of and discrimination between gram-positive and gram-negative bacteria in intraocular samples by using nested PCR
    • Carroll NM, Jaeger EE, Choudhury S, Dunlop AA, Matheson MM, Adamson P, et al. Detection of and discrimination between gram-positive and gram-negative bacteria in intraocular samples by using nested PCR. J Clin Microbiol 2000;38:1753-1757.
    • (2000) J Clin Microbiol , vol.38 , pp. 1753-1757
    • Carroll, N.M.1    Jaeger, E.E.2    Choudhury, S.3    Dunlop, A.A.4    Matheson, M.M.5    Adamson, P.6
  • 16
    • 33746642090 scopus 로고    scopus 로고
    • Development and application of multiplex polymerase chain reaction for the etiological diagnosis of infectious endophthalmitis
    • Bagyalakshmi R, Madhavan HN, Therese KL. Development and application of multiplex polymerase chain reaction for the etiological diagnosis of infectious endophthalmitis. J Postgrad Med 2006;52:179-182.
    • (2006) J Postgrad Med , vol.52 , pp. 179-182
    • Bagyalakshmi, R.1    Madhavan, H.N.2    Therese, K.L.3
  • 17
    • 0027232538 scopus 로고
    • Nested polymerase chain reaction for high-sensitivity detection of enteroviral RNA in biologic samples
    • Severini GM, Mestroni L, Falaschi A, Camerini F, Giacca M. Nested polymerase chain reaction for high-sensitivity detection of enteroviral RNA in biologic samples. J Clin Microbiol 1993;31:1345-1349.
    • (1993) J Clin Microbiol , vol.31 , pp. 1345-1349
    • Severini, G.M.1    Mestroni, L.2    Falaschi, A.3    Camerini, F.4    Giacca, M.5
  • 18
    • 0024376686 scopus 로고
    • Minimal homology requirement for PCR primer
    • Sommer R, Tautz D. Minimal homology requirement for PCR primer. Nucleic Acids Res 1989;17:6749.
    • (1989) Nucleic Acids Res , vol.17 , pp. 6749
    • Sommer, R.1    Tautz, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.