메뉴 건너뛰기




Volumn 24, Issue 4, 2013, Pages 437-441

Role of defibrillation threshold testing in the contemporary defibrillator patient population

Author keywords

amiodarone; cardiomyopathy; defibrillation threshold testing; heart failure; implantable cardioverter defibrillator

Indexed keywords

AMIODARONE; DOBUTAMINE;

EID: 84875842763     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12042     Document Type: Article
Times cited : (27)

References (40)
  • 1
    • 0016949567 scopus 로고
    • Considerations in the development of the automatic implantable defibrillator
    • Langer A, Heilman MS, Mower MM, Mirowski M,: Considerations in the development of the automatic implantable defibrillator. Med Instrum 1976; 10: 163-167.
    • (1976) Med Instrum , vol.10 , pp. 163-167
    • Langer, A.1    Heilman, M.S.2    Mower, M.M.3    Mirowski, M.4
  • 2
    • 0018184503 scopus 로고
    • A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation
    • Mirowski M, Mower MM, Langer A, Heilman MS, Schreibman J,: A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation. Circulation 1978; 58: 90-94.
    • (1978) Circulation , vol.58 , pp. 90-94
    • Mirowski, M.1    Mower, M.M.2    Langer, A.3    Heilman, M.S.4    Schreibman, J.5
  • 3
    • 0019215346 scopus 로고
    • The automatic implantable defibrillator
    • Mirowski M, Mower MM, Reid PR,: The automatic implantable defibrillator. Am Heart J 1980; 100 (6 Pt 2): 1089-1092.
    • (1980) Am Heart J , vol.100 , Issue.6 PART 2 , pp. 1089-1092
    • Mirowski, M.1    Mower, M.M.2    Reid, P.R.3
  • 4
    • 0019479339 scopus 로고
    • Clinical treatment of life-threatening ventricular tachyarrhythmias with the automatic implantable defibrillator
    • Mirowski M, Reid PR, Watkins L, Weisfeldt ML, Mower MM,: Clinical treatment of life-threatening ventricular tachyarrhythmias with the automatic implantable defibrillator. Am Heart J 1981; 102: 265-270.
    • (1981) Am Heart J , vol.102 , pp. 265-270
    • Mirowski, M.1    Reid, P.R.2    Watkins, L.3    Weisfeldt, M.L.4    Mower, M.M.5
  • 6
    • 0020001109 scopus 로고
    • Implantable automatic defibrillators: Their potential in prevention of sudden coronary death
    • Mirowski M, Mower MM, Reid PR, Watkins L Jr,: Implantable automatic defibrillators: Their potential in prevention of sudden coronary death. Ann NY Acad Sci 1982; 382: 371-380.
    • (1982) Ann NY Acad Sci , vol.382 , pp. 371-380
    • Mirowski, M.1    Mower, M.M.2    Reid, P.R.3    Watkins Jr., L.4
  • 7
    • 0020875572 scopus 로고
    • Implantable automatic cardioverter-defibrillator: Advanced technology which raises basic questions about the science of managerial decisions for clinical practice
    • Copeland RB,: Implantable automatic cardioverter-defibrillator: Advanced technology which raises basic questions about the science of managerial decisions for clinical practice. Trans Am Clin Climatol Assoc 1984; 95: 176-182.
    • (1984) Trans Am Clin Climatol Assoc , vol.95 , pp. 176-182
    • Copeland, R.B.1
  • 11
    • 0032899752 scopus 로고    scopus 로고
    • Late retesting of system performance in ICD patients without spontaneous shocks
    • Zilo P, Weiss DN, Luceri RM,. Late retesting of system performance in ICD patients without spontaneous shocks. Pacing Clin Electrophysiol 1999; 22 (1 Pt 2): 197-201.
    • (1999) Pacing Clin Electrophysiol , vol.22 , Issue.1 PART 2 , pp. 197-201
    • Zilo, P.1    Weiss, D.N.2    Luceri, R.M.3
  • 13
    • 0023911171 scopus 로고
    • Comparison of defibrillation efficacy in humans using a new catheter and superior vena cava spring-left ventricular patch electrodes
    • Winkle RA, Bach SM Jr, Mead RH, Gaudiani VA, Stinson EB, Fain ES, Schmidt P,: Comparison of defibrillation efficacy in humans using a new catheter and superior vena cava spring-left ventricular patch electrodes. J Am Coll Cardiol 1988; 11: 365-370.
    • (1988) J Am Coll Cardiol , vol.11 , pp. 365-370
    • Winkle, R.A.1    Bach Jr., S.M.2    Mead, R.H.3    Gaudiani, V.A.4    Stinson, E.B.5    Fain, E.S.6    Schmidt, P.7
  • 14
    • 0023786718 scopus 로고
    • Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator
    • Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC III,: Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator. Am J Cardiol 1988; 62: 393-398.
    • (1988) Am J Cardiol , vol.62 , pp. 393-398
    • Marchlinski, F.E.1    Flores, B.2    Miller, J.M.3    Gottlieb, C.D.4    Hargrove Iii, W.C.5
  • 16
    • 65649108965 scopus 로고    scopus 로고
    • Defibrillation threshold testing in the 21st century: Necessary or not
    • Vlay SC,: Defibrillation threshold testing in the 21st century: Necessary or not Pacing Clin Electrophysiol 2009; 32: 565-566.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 565-566
    • Vlay, S.C.1
  • 17
    • 33748784326 scopus 로고    scopus 로고
    • Near-fatal incident on routine induction of ventricular fibrillation at the replacement of an implantable cardioverter defibrillator
    • Kolb C, Zrenner B, Schmitt C,: Near-fatal incident on routine induction of ventricular fibrillation at the replacement of an implantable cardioverter defibrillator. Int J Cardiol 2006; 112: e74-e75.
    • (2006) Int J Cardiol , vol.112
    • Kolb, C.1    Zrenner, B.2    Schmitt, C.3
  • 18
    • 0028289169 scopus 로고
    • Changes in cerebral perfusion during third-generation implantable cardioverter defibrillator testing
    • Singer I, Edmonds H Jr,: Changes in cerebral perfusion during third-generation implantable cardioverter defibrillator testing. Am Heart J 1994; 127 (4 Pt 2): 1052-1057.
    • (1994) Am Heart J , vol.127 , Issue.4 PT 2 , pp. 1052-1057
    • Singer, I.1    Edmonds Jr., H.2
  • 19
    • 33644693959 scopus 로고    scopus 로고
    • Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients
    • Alter P, Waldhans S, Plachta E, Moosdorf R, Grimm W,: Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients. Pacing Clin Electrophysiol 2005; 28: 926-932.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 926-932
    • Alter, P.1    Waldhans, S.2    Plachta, E.3    Moosdorf, R.4    Grimm, W.5
  • 23
    • 79955436789 scopus 로고    scopus 로고
    • Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation
    • Michowitz Y, Lellouche N, Contractor T, Bourke T, Wiener I, Buch E, Boyle N, Bersohn M, Shivkumar K,: Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation. Europace 2011; 13: 683-688.
    • (2011) Europace , vol.13 , pp. 683-688
    • Michowitz, Y.1    Lellouche, N.2    Contractor, T.3    Bourke, T.4    Wiener, I.5    Buch, E.6    Boyle, N.7    Bersohn, M.8    Shivkumar, K.9
  • 24
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results
    • Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, Canby RC, Khalighi K, Machado C, Rubenstein DS, Volosin KJ,: Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation 2004; 110: 2591-2596.
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    Degroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7    Khalighi, K.8    MacHado, C.9    Rubenstein, D.S.10    Volosin, K.J.11
  • 25
    • 39649116512 scopus 로고    scopus 로고
    • Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation
    • Lever NA, Newall EG, Larsen PD,: Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation. Europace 2007; 9: 1054-1058.
    • (2007) Europace , vol.9 , pp. 1054-1058
    • Lever, N.A.1    Newall, E.G.2    Larsen, P.D.3
  • 26
  • 31
    • 84866344503 scopus 로고    scopus 로고
    • A plea for delivery of high-voltage shocks during implantable cardioverter-defibrillator replacement or system upgrade
    • Sticherling C, Schaer B, Kühne M, Osswald S,: A plea for delivery of high-voltage shocks during implantable cardioverter-defibrillator replacement or system upgrade. Can J Cardiol 2012;28:611.e5-6.
    • (2012) Can J Cardiol , vol.28
    • Sticherling, C.1    Schaer, B.2    Kühne, M.3    Osswald, S.4
  • 32
    • 0023360986 scopus 로고
    • The cardiac ventricular defibrillation threshold: Inherent limitations in its application and interpretation
    • McDaniel WC, Schuder JC,: The cardiac ventricular defibrillation threshold: Inherent limitations in its application and interpretation. Med Instrum 1987; 21: 170-176.
    • (1987) Med Instrum , vol.21 , pp. 170-176
    • McDaniel, W.C.1    Schuder, J.C.2
  • 34
    • 80053144164 scopus 로고    scopus 로고
    • Characterization and financial impact of implantable cardioverter- defibrillator patients without interventions 5 years after implantation
    • Reichlin T, Kühne M, Sticherling C, Osswald S, Schaer B,: Characterization and financial impact of implantable cardioverter-defibrillator patients without interventions 5 years after implantation. QJM 2011; 104: 849-857.
    • (2011) QJM , vol.104 , pp. 849-857
    • Reichlin, T.1    Kühne, M.2    Sticherling, C.3    Osswald, S.4    Schaer, B.5
  • 36
    • 78049415612 scopus 로고    scopus 로고
    • Incidence of very high defibrillation thresholds (DFT) and efficacy of subcutaneous (SQ) array insertion during implantable cardioverter defibrillator (ICD) implantation
    • Verma A, Kaplan AJ, Sarak B, Oosthuizen R, Beardsall M, Higgenbottam J, Wulffhart Z, Khaykin Y,: Incidence of very high defibrillation thresholds (DFT) and efficacy of subcutaneous (SQ) array insertion during implantable cardioverter defibrillator (ICD) implantation. J Interv Card Electrophysiol 2010; 29: 127-133.
    • (2010) J Interv Card Electrophysiol , vol.29 , pp. 127-133
    • Verma, A.1    Kaplan, A.J.2    Sarak, B.3    Oosthuizen, R.4    Beardsall, M.5    Higgenbottam, J.6    Wulffhart, Z.7    Khaykin, Y.8
  • 38
    • 33644778037 scopus 로고    scopus 로고
    • Intraoperative testing of the implantable cardioverter-defibrillator: How much is enough
    • Pires LA, Johnson KM,. Intraoperative testing of the implantable cardioverter-defibrillator: How much is enough J Cardiovasc Electrophysiol 2006; 17: 140-145.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 140-145
    • Pires, L.A.1    Johnson, K.M.2
  • 39
    • 84871256608 scopus 로고    scopus 로고
    • A randomized-controlled pilot study comparing ICD implantation with and without intraoperative defibrillation testing in patients with heart failure and severe left ventricular dysfunction: A substudy of the RAFT Trial [Internet]
    • Healey JS, Gula LJ, Birnie DH, Sterns L, Connolly SJ, Sapp J, Crystal E, Simpson C, Exner DV, Kus T, Philippon F, Wells G, Tang AS,: A randomized-controlled pilot study comparing ICD implantation with and without intraoperative defibrillation testing in patients with heart failure and severe left ventricular dysfunction: A substudy of the RAFT Trial [Internet]. J Cardiovasc Electrophysiol 2012; Available from: http://www.ncbi.nlm.nih.gov/ pubmed/22788915
    • (2012) J Cardiovasc Electrophysiol
    • Healey, J.S.1    Gula, L.J.2    Birnie, D.H.3    Sterns, L.4    Connolly, S.J.5    Sapp, J.6    Crystal, E.7    Simpson, C.8    Exner, D.V.9    Kus, T.10    Philippon, F.11    Wells, G.12    Tang, A.S.13
  • 40
    • 84856259355 scopus 로고    scopus 로고
    • Pre-hospital discharge testing after implantable cardioverter defibrillator implantation: A measure of safety or out of date? A retrospective analysis of 975 patients
    • Guenther M, Rauwolf T, Brüggemann B, Gerlach M, Wässnig NK, Christoph M, Braun MU, Strasser RH, Wunderlich C,: Pre-hospital discharge testing after implantable cardioverter defibrillator implantation: A measure of safety or out of date? A retrospective analysis of 975 patients. Europace 2012; 14: 217-223.
    • (2012) Europace , vol.14 , pp. 217-223
    • Guenther, M.1    Rauwolf, T.2    Brüggemann, B.3    Gerlach, M.4    Wässnig, N.K.5    Christoph, M.6    Braun, M.U.7    Strasser, R.H.8    Wunderlich, C.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.