메뉴 건너뛰기




Volumn 41, Issue 4, 2013, Pages 990-998

How to perform indexing of extravascular lung water: A validation study

Author keywords

age; extravascular lung water; gender; height; transpulmonary thermodilution; weight

Indexed keywords

ANTICONVULSIVE AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM ANTAGONIST; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; DIURETIC AGENT; HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR;

EID: 84875803831     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e318275cd75     Document Type: Article
Times cited : (23)

References (57)
  • 1
    • 70349768152 scopus 로고    scopus 로고
    • Measurement of extravascular lung water using the single indicator method in patients: Research and potential clinical value
    • Brown LM, Liu KD, Matthay MA: Measurement of extravascular lung water using the single indicator method in patients: research and potential clinical value. Am J Physiol Lung Cell Mol Physiol 2009; 297:L547-L558
    • (2009) Am J Physiol Lung Cell Mol Physiol , vol.297
    • Brown, L.M.1    Liu, K.D.2    Matthay, M.A.3
  • 2
    • 0022152605 scopus 로고
    • Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults
    • Halperin BD, Feeley TW, Mihm FG, et al: Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults. Chest 1985; 88:649-652
    • (1985) Chest , vol.88 , pp. 649-652
    • Halperin, B.D.1    Feeley, T.W.2    Mihm, F.G.3
  • 3
    • 0020451172 scopus 로고
    • Comparison of double indicator thermodilution measurements of extravascular lung water (EVLW) with radiographic estimation of lung water in trauma patients
    • Baudendistel L, Shields JB, Kaminski DL: Comparison of double indicator thermodilution measurements of extravascular lung water (EVLW) with radiographic estimation of lung water in trauma patients. J Trauma 1982; 22:983-988
    • (1982) J Trauma , vol.22 , pp. 983-988
    • Baudendistel, L.1    Shields, J.B.2    Kaminski, D.L.3
  • 4
    • 0020569871 scopus 로고
    • Value of extravascular lung water measurement vs portable chest X-ray in the management of pulmonary edema
    • Sivak ED, Richmond BJ, O'Donavan PB, et al: Value of extravascular lung water measurement vs portable chest X-ray in the management of pulmonary edema. Crit Care Med 1983; 11:498-501
    • (1983) Crit Care Med , vol.11 , pp. 498-501
    • Sivak, E.D.1    Richmond, B.J.2    O'Donavan, P.B.3
  • 5
    • 79959598982 scopus 로고    scopus 로고
    • Physical examination, central venous pressure, and chest radiography for the prediction of transpulmonary thermodilution-derived hemodynamic parameters in critically ill patients: A prospective trial
    • Saugel B, Ringmaier S, Holzapfel K, et al: Physical examination, central venous pressure, and chest radiography for the prediction of transpulmonary thermodilution-derived hemodynamic parameters in critically ill patients: A prospective trial. J Crit Care 2011; 26:402-410
    • (2011) J Crit Care , vol.26 , pp. 402-410
    • Saugel, B.1    Ringmaier, S.2    Holzapfel, K.3
  • 6
    • 37549048965 scopus 로고    scopus 로고
    • Extravascular lung water in sepsis-associated acute respiratory distress syndrome: Indexing with predicted body weight improves correlation with severity of illness and survival
    • Phillips CR, Chesnutt MS, Smith SM: Extravascular lung water in sepsis-associated acute respiratory distress syndrome: Indexing with predicted body weight improves correlation with severity of illness and survival. Crit Care Med 2008; 36:69-73
    • (2008) Crit Care Med , vol.36 , pp. 69-73
    • Phillips, C.R.1    Chesnutt, M.S.2    Smith, S.M.3
  • 7
    • 74049130855 scopus 로고    scopus 로고
    • Extravascular lung water indexed to predicted body weight is a novel predictor of intensive care unit mortality in patients with acute lung injury
    • Craig TR, Duffy MJ, Shyamsundar M, et al: Extravascular lung water indexed to predicted body weight is a novel predictor of intensive care unit mortality in patients with acute lung injury. Crit Care Med 2010; 38:114-120
    • (2010) Crit Care Med , vol.38 , pp. 114-120
    • Craig, T.R.1    Duffy, M.J.2    Shyamsundar, M.3
  • 8
    • 0036929495 scopus 로고    scopus 로고
    • Prognostic value of extravascular lung water in critically ill patients
    • Sakka SG, Klein M, Reinhart K, et al: Prognostic value of extravascular lung water in critically ill patients. Chest 2002; 122:2080-2086
    • (2002) Chest , vol.122 , pp. 2080-2086
    • Sakka, S.G.1    Klein, M.2    Reinhart, K.3
  • 9
    • 78650724988 scopus 로고    scopus 로고
    • Extravascular lung water correlates multiorgan dysfunction syndrome and mortality in sepsis
    • Chung FT, Lin HC, Kuo CH, et al: Extravascular lung water correlates multiorgan dysfunction syndrome and mortality in sepsis. PLoS One 2010; 5:e15265
    • (2010) PLoS One , vol.5
    • Chung, F.T.1    Lin, H.C.2    Kuo, C.H.3
  • 10
    • 78049238994 scopus 로고    scopus 로고
    • Extravascular lung water index as a sign of developing sepsis in burns
    • Bognar Z, Foldi V, Rezman B, et al: Extravascular lung water index as a sign of developing sepsis in burns. Burns 2010; 36:1263-1270
    • (2010) Burns , vol.36 , pp. 1263-1270
    • Bognar, Z.1    Foldi, V.2    Rezman, B.3
  • 11
    • 15844373446 scopus 로고    scopus 로고
    • Extravascular lung water in patients with severe sepsis: A prospective cohort study
    • Martin GS, Eaton S, Mealer M, et al: Extravascular lung water in patients with severe sepsis: A prospective cohort study. Crit Care 2005; 9:R74-R82
    • (2005) Crit Care , vol.9
    • Martin, G.S.1    Eaton, S.2    Mealer, M.3
  • 12
    • 85027940581 scopus 로고    scopus 로고
    • Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure
    • Lubrano R, Cecchetti C, Elli M, et al: Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure. Intensive Care Med 2011; 37:124-131
    • (2011) Intensive Care Med , vol.37 , pp. 124-131
    • Lubrano, R.1    Cecchetti, C.2    Elli, M.3
  • 13
    • 84864122136 scopus 로고    scopus 로고
    • Prognostic value of extravascular lung water index in critically ill patients: A systematic review of the literature
    • Zhang Z, Lu B, Ni H: Prognostic value of extravascular lung water index in critically ill patients: A systematic review of the literature. J Crit Care 2012; 27:420.e1-420.e8
    • (2012) J Crit Care , vol.27
    • Zhang, Z.1    Lu, B.2    Ni, H.3
  • 14
    • 42149168490 scopus 로고    scopus 로고
    • Aerosolized salbutamol accelerates the resolution of pulmonary edema after lung resection
    • Licker M, Tschopp JM, Robert J, et al: Aerosolized salbutamol accelerates the resolution of pulmonary edema after lung resection. Chest 2008; 133:845-852
    • (2008) Chest , vol.133 , pp. 845-852
    • Licker, M.1    Tschopp, J.M.2    Robert, J.3
  • 15
    • 32144437063 scopus 로고    scopus 로고
    • The beta-agonist lung injury trial (BALTI): A randomized placebo-controlled clinical trial
    • Perkins GD, McAuley DF, Thickett DR, et al: The beta-agonist lung injury trial (BALTI): A randomized placebo-controlled clinical trial. Am J Respir Crit Care Med 2006; 173:281-287
    • (2006) Am J Respir Crit Care Med , vol.173 , pp. 281-287
    • Perkins, G.D.1    McAuley, D.F.2    Thickett, D.R.3
  • 16
    • 0026800809 scopus 로고
    • Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization
    • Mitchell JP, Schuller D, Calandrino FS, et al: Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am Rev Respir Dis 1992; 145:990-998
    • (1992) Am Rev Respir Dis , vol.145 , pp. 990-998
    • Mitchell, J.P.1    Schuller, D.2    Calandrino, F.S.3
  • 17
    • 0023514974 scopus 로고
    • A prospective study of lung water measurements during patient management in an intensive care unit
    • Eisenberg PR, Hansbrough JR, Anderson D, et al: A prospective study of lung water measurements during patient management in an intensive care unit. Am Rev Respir Dis 1987; 136:662-668
    • (1987) Am Rev Respir Dis , vol.136 , pp. 662-668
    • Eisenberg, P.R.1    Hansbrough, J.R.2    Anderson, D.3
  • 18
    • 34247166300 scopus 로고    scopus 로고
    • Bedside assessment of extravascular lung water by dilution methods: Temptations and pitfalls
    • Michard F: Bedside assessment of extravascular lung water by dilution methods: Temptations and pitfalls. Crit Care Med 2007; 35:1186-1192
    • (2007) Crit Care Med , vol.35 , pp. 1186-1192
    • Michard, F.1
  • 20
    • 0031473392 scopus 로고    scopus 로고
    • Identifying patients with ARDS: Time for a different approach
    • Schuster DP: Identifying patients with ARDS: Time for a different approach. Intensive Care Med 1997; 23:1197-1203
    • (1997) Intensive Care Med , vol.23 , pp. 1197-1203
    • Schuster, D.P.1
  • 21
    • 27944497478 scopus 로고
    • The adult respiratory distress syndrome: An objective clinical definition
    • Lewis F, Pfeiffere UJ (Eds). Berlin, Germany, Springer
    • Sturm J, Regel G, Neumann C, et al: The adult respiratory distress syndrome: An objective clinical definition. In: Practical Applications of Fiberoptics in Critical Care Monitoring. Lewis F, Pfeiffere UJ (Eds). Berlin, Germany, Springer, 1990, pp. 181-188
    • (1990) Practical Applications of Fiberoptics in Critical Care Monitoring , pp. 181-188
    • Sturm, J.1    Regel, G.2    Neumann, C.3
  • 22
    • 84857586802 scopus 로고    scopus 로고
    • A new and simple definition for acute lung injury*
    • Michard F, Fernandez-Mondejar E, Kirov MY, et al: A new and simple definition for acute lung injury*. Crit Care Med 2012; 40:1004-1006
    • (2012) Crit Care Med , vol.40 , pp. 1004-1006
    • Michard, F.1    Fernandez-Mondejar, E.2    Kirov, M.Y.3
  • 23
    • 84857621506 scopus 로고    scopus 로고
    • Extravascular lung water predicts progression to acute lung injury in patients with increased risk
    • LeTourneau JL, Pinney J, Phillips CR: Extravascular lung water predicts progression to acute lung injury in patients with increased risk. Crit Care Med 2012; 40:847-854
    • (2012) Crit Care Med , vol.40 , pp. 847-854
    • Letourneau, J.L.1    Pinney, J.2    Phillips, C.R.3
  • 24
    • 0034027184 scopus 로고    scopus 로고
    • Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
    • Sakka SG, Rühl CC, Pfeiffer UJ, et al: Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med 2000; 26:180-187
    • (2000) Intensive Care Med , vol.26 , pp. 180-187
    • Sakka, S.G.1    Rühl, C.C.2    Pfeiffer, U.J.3
  • 25
    • 84861553874 scopus 로고    scopus 로고
    • Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters
    • Kiefer N, Hofer CK, Marx G, et al: Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters. Crit Care 2012; 16:R98
    • (2012) Crit Care , vol.16
    • Kiefer, N.1    Hofer, C.K.2    Marx, G.3
  • 26
    • 54449100105 scopus 로고    scopus 로고
    • Extravascular lung water volume measurement by a novel lithium-thermal indicator dilution method: Comparison of three techniques to post-mortem gravimetry
    • Maddison B, Giudici R, Calzia E, et al: Extravascular lung water volume measurement by a novel lithium-thermal indicator dilution method: Comparison of three techniques to post-mortem gravimetry. Intensive Care Med 2008; 34:2106-2111
    • (2008) Intensive Care Med , vol.34 , pp. 2106-2111
    • Maddison, B.1    Giudici, R.2    Calzia, E.3
  • 27
    • 77956489043 scopus 로고    scopus 로고
    • Validation of extravascular lung water measurement by single transpulmonary thermodilution: Human autopsy study
    • Tagami T, Kushimoto S, Yamamoto Y, et al: Validation of extravascular lung water measurement by single transpulmonary thermodilution: Human autopsy study. Crit Care 2010; 14:R162
    • (2010) Crit Care , vol.14
    • Tagami, T.1    Kushimoto, S.2    Yamamoto, Y.3
  • 28
    • 15844382038 scopus 로고    scopus 로고
    • Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep
    • Kirov MY, Kuzkov VV, Kuklin VN, et al: Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep. Crit Care 2004; 8:R451-R458
    • (2004) Crit Care , vol.8
    • Kirov, M.Y.1    Kuzkov, V.V.2    Kuklin, V.N.3
  • 29
    • 77955240582 scopus 로고    scopus 로고
    • Radiographic lung density assessed by computed tomography is associated with extravascular lung water content
    • Kuzkov VV, Suborov EV, Kirov MY, et al: Radiographic lung density assessed by computed tomography is associated with extravascular lung water content. Acta Anaesthesiol Scand 2010; 54:1018-1026
    • (2010) Acta Anaesthesiol Scand , vol.54 , pp. 1018-1026
    • Kuzkov, V.V.1    Suborov, E.V.2    Kirov, M.Y.3
  • 30
    • 45149107973 scopus 로고    scopus 로고
    • Accurate characterization of extravascular lung water in acute respiratory distress syndrome
    • Berkowitz DM, Danai PA, Eaton S, et al: Accurate characterization of extravascular lung water in acute respiratory distress syndrome. Crit Care Med 2008; 36:1803-1809
    • (2008) Crit Care Med , vol.36 , pp. 1803-1809
    • Berkowitz, D.M.1    Danai, P.A.2    Eaton, S.3
  • 31
    • 0020183953 scopus 로고
    • Extravascular lung water values in patients undergoing coronary artery bypass surgery
    • Sivak ED, Starr NJ, Graves JW, et al: Extravascular lung water values in patients undergoing coronary artery bypass surgery. Crit Care Med 1982; 10:593-596
    • (1982) Crit Care Med , vol.10 , pp. 593-596
    • Sivak, E.D.1    Starr, N.J.2    Graves, J.W.3
  • 32
    • 0036206614 scopus 로고    scopus 로고
    • Effects of dexamethasone on intravascular and extravascular fluid balance in patients undergoing coronary bypass surgery with cardiopulmonary bypass
    • von Spiegel T, Giannaris S, Wietasch GJ, et al: Effects of dexamethasone on intravascular and extravascular fluid balance in patients undergoing coronary bypass surgery with cardiopulmonary bypass. Anesthesiology 2002; 96:827-834
    • (2002) Anesthesiology , vol.96 , pp. 827-834
    • Von Spiegel, T.1    Giannaris, S.2    Wietasch, G.J.3
  • 33
    • 0017681493 scopus 로고
    • Extravascular lung water accumulation in patients following coronary artery surgery
    • Byrick RJ, Kay C, Noble WH: Extravascular lung water accumulation in patients following coronary artery surgery. Can Anaesth Soc J 1977; 24:332-345
    • (1977) Can Anaesth Soc J , vol.24 , pp. 332-345
    • Byrick, R.J.1    Kay, C.2    Noble, W.H.3
  • 34
    • 0022621128 scopus 로고
    • Evaluation of extravascular lung water by single thermal indicator
    • Baudendistel LJ, Kaminski DL, Dahms TE: Evaluation of extravascular lung water by single thermal indicator. Crit Care Med 1986; 14:52-56
    • (1986) Crit Care Med , vol.14 , pp. 52-56
    • Baudendistel, L.J.1    Kaminski, D.L.2    Dahms, T.E.3
  • 35
    • 0020629058 scopus 로고
    • Clinical studies of measuring extravascular lung water by the thermal dye technique in critically ill patients
    • Sibbald WJ, Warshawski FJ, Short AK, et al: Clinical studies of measuring extravascular lung water by the thermal dye technique in critically ill patients. Chest 1983; 83:725-731
    • (1983) Chest , vol.83 , pp. 725-731
    • Sibbald, W.J.1    Warshawski, F.J.2    Short, A.K.3
  • 37
    • 0019457107 scopus 로고
    • Reference spirometric values using techniques and equipment that meet ATS recommendations
    • Crapo RO, Morris AH, Gardner RM: Reference spirometric values using techniques and equipment that meet ATS recommendations. Am Rev Respir Dis 1981; 123:659-664
    • (1981) Am Rev Respir Dis , vol.123 , pp. 659-664
    • Crapo, R.O.1    Morris, A.H.2    Gardner, R.M.3
  • 38
    • 77951634258 scopus 로고    scopus 로고
    • Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients
    • Wolf S, Riess A, Landscheidt JF, et al: Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients. Crit Care 2009; 13:R202
    • (2009) Crit Care , vol.13
    • Wolf, S.1    Riess, A.2    Landscheidt, J.F.3
  • 40
    • 0031979188 scopus 로고    scopus 로고
    • Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function
    • Godje O, Peyerl M, Seebauer T, et al: Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function. Chest 1998; 113:1070-1077
    • (1998) Chest , vol.113 , pp. 1070-1077
    • Godje, O.1    Peyerl, M.2    Seebauer, T.3
  • 42
    • 0016355478 scopus 로고
    • A new look at the statistical model identification
    • Akaike H: A new look at the statistical model identification. IEEE Trans Auto Contl 1974; 19:716-723
    • (1974) IEEE Trans Auto Contl , vol.19 , pp. 716-723
    • Akaike, H.1
  • 43
    • 0002344794 scopus 로고
    • Bootstrap methods: Another look at the jackknife
    • Efron B: Bootstrap Methods: Another Look at the Jackknife. Ann Stat 1979; 7:1-26
    • (1979) Ann Stat , vol.7 , pp. 1-26
    • Efron, B.1
  • 44
    • 78651258580 scopus 로고    scopus 로고
    • Calculation of the normal range of extravascular lung water
    • Zhang Z Jr: Calculation of the normal range of extravascular lung water. Crit Care 2010; 14:448
    • (2010) Crit Care , vol.14 , pp. 448
    • Zhang Jr., Z.1
  • 45
    • 78651023166 scopus 로고
    • Fallacy of per-weight and per-surface area standards, and their relation to spurious correlation
    • Tanner JM: Fallacy of per-weight and per-surface area standards, and their relation to spurious correlation. J Appl Physiol 1949; 2:1-15
    • (1949) J Appl Physiol , vol.2 , pp. 1-15
    • Tanner, J.M.1
  • 46
    • 0028951021 scopus 로고
    • Fallacy of indexing renal and systemic hemodynamic measurements for body surface area
    • Turner ST, Reilly SL: Fallacy of indexing renal and systemic hemodynamic measurements for body surface area. Am J Physiol 1995; 268(4 Pt 2):R978-R988
    • (1995) Am J Physiol , vol.268 , Issue.4 PART 2
    • Turner, S.T.1    Reilly, S.L.2
  • 47
    • 33645824125 scopus 로고    scopus 로고
    • Hemodynamic monitoring in obese patients: The impact of body mass index on cardiac output and stroke volume
    • Stelfox HT, Ahmed SB, Ribeiro RA, et al: Hemodynamic monitoring in obese patients: The impact of body mass index on cardiac output and stroke volume. Crit Care Med 2006; 34:1243-1246
    • (2006) Crit Care Med , vol.34 , pp. 1243-1246
    • Stelfox, H.T.1    Ahmed, S.B.2    Ribeiro, R.A.3
  • 48
    • 77953125605 scopus 로고    scopus 로고
    • Extravascular lung water index measurement in critically ill children does not correlate with a chest X-ray score of pulmonary edema
    • Lemson J, van Die LE, Hemelaar AE, et al: Extravascular lung water index measurement in critically ill children does not correlate with a chest X-ray score of pulmonary edema. Crit Care 2010; 14:R105
    • (2010) Crit Care , vol.14
    • Lemson, J.1    Van Die, L.E.2    Hemelaar, A.E.3
  • 49
    • 60849104458 scopus 로고    scopus 로고
    • Cardiac output and blood volume parameters using femoral arterial thermodilution
    • López-Herce J, Bustinza A, Sancho L, et al: Cardiac output and blood volume parameters using femoral arterial thermodilution. Pediatr Int 2009; 51:59-65
    • (2009) Pediatr Int , vol.51 , pp. 59-65
    • López-Herce, J.1    Bustinza, A.2    Sancho, L.3
  • 50
    • 0036793048 scopus 로고    scopus 로고
    • Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants
    • Schiffmann H, Erdlenbruch B, Singer D, et al: Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants. J Cardiothorac Vasc Anesth 2002; 16:592-597
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 592-597
    • Schiffmann, H.1    Erdlenbruch, B.2    Singer, D.3
  • 51
    • 34547652664 scopus 로고    scopus 로고
    • Limitations of extravascular lung water assessment by dilution methods in children
    • Cid JL, Rupérez M, Sánchez C, et al: Limitations of extravascular lung water assessment by dilution methods in children. Crit Care Med 2007; 35:2001-2002
    • (2007) Crit Care Med , vol.35 , pp. 2001-2002
    • Cid, J.L.1    Rupérez, M.2    Sánchez, C.3
  • 52
    • 79960700296 scopus 로고    scopus 로고
    • Extravascular lung water index and global end-diastolic volume index should be corrected in children
    • Lemson J, Merkus P, van der Hoeven JG: Extravascular lung water index and global end-diastolic volume index should be corrected in children. J Crit Care 2011; 26:432.e7-432.12
    • (2011) J Crit Care , vol.26
    • Lemson, J.1    Merkus, P.2    Van Der Hoeven, J.G.3
  • 53
    • 33646182601 scopus 로고    scopus 로고
    • Small increases in extravascular lung water are accurately detected by transpulmonary thermodilution
    • Fernández-Mondéjar E, Rivera-Fernández R, García-Delgado M, et al: Small increases in extravascular lung water are accurately detected by transpulmonary thermodilution. J Trauma 2005; 59:1420-1423
    • (2005) J Trauma , vol.59 , pp. 1420-1423
    • Fernández-Mondéjar, E.1    Rivera-Fernández, R.2    García-Delgado, M.3
  • 54
    • 48949119362 scopus 로고    scopus 로고
    • Indicator dilution measurements of extravascular lung water: Basic assumptions and observations
    • Effros RM, Pornsuriyasak P, Porszasz J, et al: Indicator dilution measurements of extravascular lung water: Basic assumptions and observations. Am J Physiol Lung Cell Mol Physiol 2008; 294: L1023-L1031
    • (2008) Am J Physiol Lung Cell Mol Physiol , vol.294
    • Effros, R.M.1    Pornsuriyasak, P.2    Porszasz, J.3
  • 55
    • 78650842325 scopus 로고    scopus 로고
    • Dynamics of extravascular pulmonary water and intracranial pressure in patients with ischemic stroke
    • Verein M, Valiahmedov A, Churliaev Y, et al: Dynamics of extravascular pulmonary water and intracranial pressure in patients with ischemic stroke. Semin Cardiothorac Vasc Anesth 2010; 14:226-230
    • (2010) Semin Cardiothorac Vasc Anesth , vol.14 , pp. 226-230
    • Verein, M.1    Valiahmedov, A.2    Churliaev, Y.3
  • 56
    • 68149141593 scopus 로고    scopus 로고
    • Hemodynamic changes after administration of mannitol measured by a noninvasive cardiac output monitor
    • Sabharwal N, Rao GS, Ali Z, et al: Hemodynamic changes after administration of mannitol measured by a noninvasive cardiac output monitor. J Neurosurg Anesthesiol 2009; 21:248-252
    • (2009) J Neurosurg Anesthesiol , vol.21 , pp. 248-252
    • Sabharwal, N.1    Rao, G.S.2    Ali, Z.3
  • 57
    • 84857051871 scopus 로고    scopus 로고
    • Changes in left ventricular preload, afterload, and cardiac output in response to a single dose of mannitol in neurosurgical patients undergoing craniotomy: A transesophageal echocardiographic study
    • Chatterjee N, Koshy T, Misra S, et al: Changes in left ventricular preload, afterload, and cardiac output in response to a single dose of mannitol in neurosurgical patients undergoing craniotomy: A transesophageal echocardiographic study. J Neurosurg Anesthesiol 2012; 24:25-29
    • (2012) J Neurosurg Anesthesiol , vol.24 , pp. 25-29
    • Chatterjee, N.1    Koshy, T.2    Misra, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.