메뉴 건너뛰기




Volumn 39, Issue , 2012, Pages 21-24

Automatic detection of chest compression pauses using the transthoracic impedance signal

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE THRESHOLDS; AUTOMATIC DETECTION; CARDIAC ARREST; CARDIOPULMONARY RESUSCITATION; CHEST COMPRESSIONS; POSITIVE PREDICTIVE VALUES; QUALITY EVALUATION; TEST SETS;

EID: 84875666839     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (13)

References (7)
  • 1
    • 78049485419 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2010 section 2. adult basic life support and use of automated external defibrillators
    • Koster R, Baubin M, Bossaert L, Caballero A, Cassan P, Castŕen M, Granja C, Handley A, Monsieurs K, Perkins G, et al. European resuscitation council guidelines for resuscitation 2010 section 2. adult basic life support and use of automated external defibrillators. Resuscitation 2010; 81(10):1277.
    • (2010) Resuscitation , vol.81 , Issue.10 , pp. 1277
    • Koster, R.1    Baubin, M.2    Bossaert, L.3    Caballero, A.4    Cassan, P.5    Castŕen, M.6    Granja, C.7    Handley, A.8    Monsieurs, K.9    Perkins, G.10
  • 3
    • 0021170163 scopus 로고
    • Advance prediction of transthoracic impedance in human defibrillation and cardioversion: Importance of impedance in determining the success of low-energy shocks
    • Kerber RE, Kouba C, Martins J, Kelly K, Low R, Hoyt R, Ferguson D, Bailey L, Bennett P, Charbonnier F. Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of low-energy shocks. Circulation 1984;70(2):303-308.
    • (1984) Circulation , vol.70 , Issue.2 , pp. 303-308
    • Kerber, R.E.1    Kouba, C.2    Martins, J.3    Kelly, K.4    Low, R.5    Hoyt, R.6    Ferguson, D.7    Bailey, L.8    Bennett, P.9    Charbonnier, F.10
  • 5
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study
    • Kramer-Johansen J, Myklebust H, Wik L, Fellows B, Svensson L, Sørebø H, Steen P. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006;71(3):283-292.
    • (2006) Resuscitation , vol.71 , Issue.3 , pp. 283-292
    • Kramer-Johansen, J.1    Myklebust, H.2    Wik, L.3    Fellows, B.4    Svensson, L.5    Sørebø, H.6    Steen, P.7
  • 6
    • 39749133456 scopus 로고    scopus 로고
    • Time used for ventilation in two-rescuer cpr with a bag-valve-mask device during out-of-hospital cardiac arrest
    • ∅degaard S, Pillgram M, Berg N, Olasveengen T, Kramer- Johansen J. Time used for ventilation in two-rescuer cpr with a bag-valve-mask device during out-of-hospital cardiac arrest. Resuscitation 2008;77(1):57-62.
    • (2008) Resuscitation , vol.77 , Issue.1 , pp. 57-62
    • Degaard, S.1    Pillgram, M.2    Berg, N.3    Olasveengen, T.4    Kramer- Johansen, J.5
  • 7
    • 84865303429 scopus 로고    scopus 로고
    • A high-temporal resolution algorithm to discriminate shockable from nonshockable rhythms in adults and children
    • Irusta U, Ruiz J, Aramendi E, Ruiz de Gauna S, Ayala U, Alonso E. A high-temporal resolution algorithm to discriminate shockable from nonshockable rhythms in adults and children. Resuscitation 2012;83(9):1090-1097.
    • (2012) Resuscitation , vol.83 , Issue.9 , pp. 1090-1097
    • Irusta, U.1    Ruiz, J.2    Aramendi, E.3    Ruiz De Gauna, S.4    Ayala, U.5    Alonso, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.