메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 972-980

Investigation on voltage sags caused by DG anti-islanding protection

Author keywords

Anti islanding protection; distributed generation; power quality (PQ); voltage sag

Indexed keywords

ANTI-ISLANDING PROTECTION; DISTRIBUTED GENERATORS; DISTRIBUTION SYSTEMS; FLOW-BASED METHODS; RE CLOSERS; SENSITIVITY STUDIES; VOLTAGE DEPRESSIONS; VOLTAGE SAGS;

EID: 84875642201     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2012.2237419     Document Type: Article
Times cited : (45)

References (19)
  • 4
    • 77954033643 scopus 로고    scopus 로고
    • Hybrid method to assess sensitive process interruption costs due to faults in electric power distribution networks
    • Jul
    • J. C. Cebrian and N. Kagan, "Hybrid method to assess sensitive process interruption costs due to faults in electric power distribution networks," IEEE Trans. Power Del., vol. 25, no. 3, pp. 1686-1696, Jul. 2010.
    • (2010) IEEE Trans. Power Del. , vol.25 , Issue.3 , pp. 1686-1696
    • Cebrian, J.C.1    Kagan, N.2
  • 5
    • 0025465311 scopus 로고
    • Effects of momentary voltage dips on the operation of induction and synchronous motors
    • DOI 10.1109/28.55998
    • J. C. Das, "Effects of momentary voltage dips on the operation of induction and synchronous motors," IEEE Trans. Ind. Appl., vol. 26, no. 4, pp. 711-718, Jul./Aug. 1990. (Pubitemid 20726380)
    • (1990) IEEE Transactions on Industry Applications , vol.26 , Issue.4 , pp. 711-718
    • Das, J.C.1
  • 6
    • 79959759401 scopus 로고    scopus 로고
    • Site and system indices for power-quality characterization of distributed networks with distributed generation
    • Jul
    • A. Bracale, P. Caramia, G. Carpinelli, A. Russo, and P. Verde, "Site and system indices for power-quality characterization of distributed networks with distributed generation," IEEE Trans. Power Del., vol. 26, no. 3, pp. 1304-1316, Jul. 2011.
    • (2011) IEEE Trans. Power Del. , vol.26 , Issue.3 , pp. 1304-1316
    • Bracale, A.1    Caramia, P.2    Carpinelli, G.3    Russo, A.4    Verde, P.5
  • 7
    • 77956051526 scopus 로고    scopus 로고
    • The effect of size of DG on voltage flicker and voltage sag in closed-loop distribution system
    • A. Saidian, D. Mirabbasi, and M. Heidari, "The effect of size of DG on voltage flicker and voltage sag in closed-loop distribution system," in Proc. 5th IEEE Conf. Ind. Electron. Appl., 2010, pp. 68-72.
    • (2010) Proc. 5th IEEE Conf. Ind. Electron. Appl. , pp. 68-72
    • Saidian, A.1    Mirabbasi, D.2    Heidari, M.3
  • 8
    • 77952311496 scopus 로고    scopus 로고
    • Method for determining the maximum allowable penetration level of distributed generation without steady-state voltage violations
    • H. M. Ayres, W. Freitas, M. C. de Almeida, and L. C. P. da Silva, "Method for determining the maximum allowable penetration level of distributed generation without steady-state voltage violations," Inst. Eng. Technol. Gen., Transm. Distrib., vol. 4, no. 4, pp. 495-508, 2010.
    • (2010) Inst. Eng. Technol. Gen., Transm. Distrib. , vol.4 , Issue.4 , pp. 495-508
    • Ayres, H.M.1    Freitas, W.2    De Almeida, M.C.3    Da Silva, L.C.P.4
  • 9
    • 43849092280 scopus 로고    scopus 로고
    • Distributed reactive power generation control for voltage rise mitigation in distribution networks
    • DOI 10.1109/TPWRS.2008.919203
    • P. M. S. Carvalho, P. F. Correia, and L. A. F. Pereira, "Distributed reactive power generation control for voltage rise mitigation in distribution networks," IEEE Trans. Power Syst., vol. 23, no. 2, pp. 766-772, May 2008. (Pubitemid 351695857)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 766-772
    • Carvalho, P.M.S.1    Correia, P.F.2    Ferreira, L.A.F.M.3
  • 10
    • 71849089084 scopus 로고    scopus 로고
    • Impact of distributed generation on distribution protection and power quality
    • J. A. Martinez and J. Martin-Anedo, "Impact of distributed generation on distribution protection and power quality," in Proc. Power Energy Soc. Gen. Meeting, 2009, pp. 1-6.
    • (2009) Proc. Power Energy Soc. Gen. Meeting , pp. 1-6
    • Martinez, J.A.1    Martin-Anedo, J.2
  • 12
    • 37749009507 scopus 로고    scopus 로고
    • Voltage sags and the response of a synchronous distributed generator: A case study
    • Jan
    • E. R. Collins and J. Jiang, "Voltage sags and the response of a synchronous distributed generator: a case study," IEEE Trans. Power Del., vol. 23, no. 1, pp. 442-448, Jan. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.1 , pp. 442-448
    • Collins, E.R.1    Jiang, J.2
  • 14
    • 32144458236 scopus 로고    scopus 로고
    • Comparative analysis between synchronous and induction machines for distributed generation applications
    • DOI 10.1109/TPWRS.2005.860931
    • W. Freitas, J. C. M. Vieira, A. Morelato, L. C. P. da Silva, V. F. da Costa, and F. A. B. Lemos, "Comparative analysis between synchronous and induction machines for distributed generation applications," IEEE Trans. Power Del., vol. 21, no. 1, pp. 301-311, Jan. 2006. (Pubitemid 43204729)
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.1 , pp. 301-311
    • Freitas, W.1    Vieira, J.C.M.2    Morelato, A.3    Da Silva, L.C.P.4    Da Costa, V.F.5    Lemos, F.A.B.6
  • 15
    • 76649120856 scopus 로고    scopus 로고
    • Network distributed generation capacity analysis using OPF with voltage step constraints
    • Feb
    • C. J. Dent, L. F. Ochoa, and G. P. Harrison, "Network distributed generation capacity analysis using OPF with voltage step constraints," IEEE Trans. Power Syst., vol. 25, no. 1, pp. 292-304, Feb. 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.1 , pp. 292-304
    • Dent, C.J.1    Ochoa, L.F.2    Harrison, G.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.