메뉴 건너뛰기




Volumn 39, Issue , 2012, Pages 633-636

Interest of RR deceleration for diagnosis of late onset sepsis

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE ROC CURVE; BLOOD CULTURE; CASE-CONTROL STUDY; CLINICAL SIGNS; HEART RATE VARIABILITY; LABORATORY TEST; PREDICTIVE ACCURACY; PREMATURE INFANTS;

EID: 84875640566     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 61849151297 scopus 로고    scopus 로고
    • Uncorrelated randomness of the heart rate is associated with sepsis in sick premature infants
    • Beuchée A, Carrault G, Bansard J, Boutaric E, Bétré mieux P, Pladys P. Uncorrelated randomness of the heart rate is associated with sepsis in sick premature infants. Neonatology 2009; 96(2): 109-114.
    • (2009) Neonatology , vol.96 , Issue.2 , pp. 109-114
    • Beuchée, A.1    Carrault, G.2    Bansard, J.3    Boutaric, E.4    Bétré mieux, P.5    Pladys, P.6
  • 4
    • 79953806125 scopus 로고    scopus 로고
    • Respiration signal as a promising diagnostic tool for late onset sepsis in premature newborns
    • IEEE
    • Navarro X, Porée F, Beuchée A, Carrault G. Respiration signal as a promising diagnostic tool for late onset sepsis in premature newborns. In Computers in Cardiology, 2010. IEEE, 2010; 947-950.
    • (2010) Computers in Cardiology, 2010 , pp. 947-950
    • Navarro, X.1    Porée, F.2    Beuchée, A.3    Carrault, G.4
  • 5
    • 50149101092 scopus 로고    scopus 로고
    • Heart rate and respiration relationships as a diagnostic tool for late onset sepsis in sick preterm infants
    • IEEE
    • Loforte R, Carrault G, Mainardi L, Beuchée A. Heart rate and respiration relationships as a diagnostic tool for late onset sepsis in sick preterm infants. In Computers in Cardiology, 2006. IEEE, 2006; 737-740.
    • (2006) Computers in Cardiology, 2006 , pp. 737-740
    • Loforte, R.1    Carrault, G.2    Mainardi, L.3    Beuchée, A.4
  • 6
    • 23244437217 scopus 로고    scopus 로고
    • Heart rate characteristics and laboratory tests in neonatal sepsis
    • Griffin M, Lake D, Moorman J. Heart rate characteristics and laboratory tests in neonatal sepsis. Pediatrics 2005; 115(4): 937-941.
    • (2005) Pediatrics , vol.115 , Issue.4 , pp. 937-941
    • Griffin, M.1    Lake, D.2    Moorman, J.3
  • 7
    • 77952677743 scopus 로고    scopus 로고
    • Time-frequency relationships between heart rate and respiration: A diagnosis tool for late onset sepsis in sick premature infants
    • IEEE
    • Carrault G, Beuchée A, Pladys P, Senhadji L, Hernández A. Time-frequency relationships between heart rate and respiration: A diagnosis tool for late onset sepsis in sick premature infants. In Computers in Cardiology, 2009. IEEE, 2009; 369-372.
    • (2009) Computers in Cardiology, 2009 , pp. 369-372
    • Carrault, G.1    Beuchée, A.2    Pladys, P.3    Senhadji, L.4    Hernández, A.5
  • 8
    • 77649135457 scopus 로고    scopus 로고
    • Improving ECG beats delineation with an evolutionary optimization process
    • Dumont J, Hernández AI, Carrault G. Improving ECG beats delineation with an evolutionary optimization process. IEEE Trans Biomed Eng 2010; 57: 607-15.
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 607-15
    • Dumont, J.1    Hernández, A.I.2    Carrault, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.