메뉴 건너뛰기




Volumn 30, Issue 2, 2013, Pages 142-152

Diagnostic accuracy of urine dipstick testing in screening for microalbuminuria in type 2 diabetes: A cohort study in primary care

Author keywords

Albuminuria; Point of care system; Sensitivity and specificity; Type 2 diabetes mellitus

Indexed keywords

AGE DISTRIBUTION; AGED; ALBUMIN CREATININE RATIO; ARTICLE; COHORT ANALYSIS; DIAGNOSTIC ACCURACY; FEMALE; GENERAL PRACTICE; HUMAN; LABORATORY TEST; MAJOR CLINICAL STUDY; MALE; MICROALBUMINURIA; NON INSULIN DEPENDENT DIABETES MELLITUS; PRACTICE GUIDELINE; PRIMARY MEDICAL CARE; SCREENING TEST; SENSITIVITY AND SPECIFICITY; SEX DIFFERENCE; UNITED KINGDOM; URINE DIPSTICK TESTING; UROGENITAL SYSTEM PARAMETERS; UROLOGIC EXAMINATION;

EID: 84875636022     PISSN: 02632136     EISSN: 14602229     Source Type: Journal    
DOI: 10.1093/fampra/cms057     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 0035948631 scopus 로고    scopus 로고
    • Albuminuria and risk of cardiovascular events, death, and heart failure in diabetic and nondiabetic individuals
    • Gerstein HC, Mann JF, Yi Q et al. Albuminuria and risk of cardiovascular events, death, and heart failure in diabetic and nondiabetic individuals. JAMA 2001; 286: 421-6.
    • (2001) JAMA , vol.286 , pp. 421-426
    • Gerstein, H.C.1    Mann, J.F.2    Yi, Q.3
  • 3
    • 84855185039 scopus 로고    scopus 로고
    • American Diabetes Association. Standards of medical care in diabetes - 2012
    • American Diabetes Association. Standards of medical care in diabetes - 2012. Diabetes Care 2012; 35 (suppl 1): S11-63.
    • (2012) Diabetes Care , vol.35 , Issue.SUPPL 1
  • 4
    • 79957715132 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Arnold M, Bakris GL et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2011; 57: e1-47.
    • (2011) Clin Chem , vol.57
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3
  • 5
    • 79958260885 scopus 로고    scopus 로고
    • Identification and management of albuminuria in the primary care setting
    • Kuritzky L, Toto R, Van Buren P. Identification and management of albuminuria in the primary care setting. J Clin Hypertens (Greenwich) 2011; 13: 438-49.
    • (2011) J Clin Hypertens (Greenwich) , vol.13 , pp. 438-449
    • Kuritzky, L.1    Toto, R.2    Van Buren, P.3
  • 6
    • 84875617395 scopus 로고    scopus 로고
    • Albuminuria. accessed on 16 March 2012
    • Albuminuria. Johns Hopkins Diabetes Guide. http://www.hopkinsguides.com/hopkins/ub/view/Johns_Hopkins_Diabetes_Guide/547004/all/Albuminuria (accessed on 16 March 2012).
    • Johns Hopkins Diabetes Guide.
  • 8
    • 0034890553 scopus 로고    scopus 로고
    • Screening for microalbuminuria to prevent nephropathy in patients with diabetes: a systematic review of the evidence
    • Scheid DC, McCarthy LH, Lawler FH, Hamm RM, Reilly KE. Screening for microalbuminuria to prevent nephropathy in patients with diabetes: a systematic review of the evidence. J Fam Pract 2001; 50: 661-8.
    • (2001) J Fam Pract , vol.50 , pp. 661-668
    • Scheid, D.C.1    McCarthy, L.H.2    Lawler, F.H.3    Hamm, R.M.4    Reilly, K.E.5
  • 9
    • 0022508704 scopus 로고
    • The Diabetes Control and Complications Trial (DCCT). Design and methodologic considerations for the feasibility phase
    • The DCCT Research Group.
    • The DCCT Research Group. The Diabetes Control and Complications Trial (DCCT). Design and methodologic considerations for the feasibility phase. Diabetes 1986; 35: 530-45.
    • (1986) Diabetes , vol.35 , pp. 530-545
  • 10
    • 0242268986 scopus 로고    scopus 로고
    • Deficiency in the detection of microalbuminuria by urinary dipstick in diabetic patients
    • Comper WD, Jerums G, Osicka TM. Deficiency in the detection of microalbuminuria by urinary dipstick in diabetic patients. Diabetes Care 2003; 26: 3195-6.
    • (2003) Diabetes Care , vol.26 , pp. 3195-3196
    • Comper, W.D.1    Jerums, G.2    Osicka, T.M.3
  • 12
    • 38349066476 scopus 로고    scopus 로고
    • A comparative evaluation of various methods for microalbuminuria screening
    • Sarafidis PA, Riehle J, Bogojevic Z et al. A comparative evaluation of various methods for microalbuminuria screening. Am J Nephrol 2008; 28: 324-9.
    • (2008) Am J Nephrol , vol.28 , pp. 324-329
    • Sarafidis, P.A.1    Riehle, J.2    Bogojevic, Z.3
  • 13
    • 0030833971 scopus 로고    scopus 로고
    • Multicenter evaluation of the Micral-Test II test strip, an immunologic rapid test for the detection of microalbuminuria
    • Mogensen CE, Viberti GC, Peheim E et al. Multicenter evaluation of the Micral-Test II test strip, an immunologic rapid test for the detection of microalbuminuria. Diabetes Care 1997; 20: 1642-6.
    • (1997) Diabetes Care , vol.20 , pp. 1642-1646
    • Mogensen, C.E.1    Viberti, G.C.2    Peheim, E.3
  • 14
    • 0036835754 scopus 로고    scopus 로고
    • Cost-effectiveness of two screening programs for microalbuminuria in type 2 diabetes
    • Author reply 2104
    • Lepore G, Maglio ML, Nosari I, Dodesini AR, Trevisan R. Cost-effectiveness of two screening programs for microalbuminuria in type 2 diabetes. Diabetes Care 2002; 25: 2103-4; author reply 2104.
    • (2002) Diabetes Care , vol.25 , pp. 2103-2104
    • Lepore, G.1    Maglio, M.L.2    Nosari, I.3    Dodesini, A.R.4    Trevisan, R.5
  • 15
    • 42749093269 scopus 로고    scopus 로고
    • Évaluation du Micral Test® en vue du dépistage de la microalbuminurie en biologie délocalisée
    • Szymanowicz A, Blanc-Bernard E, Roche C et al. Évaluation du Micral Test® en vue du dépistage de la microalbuminurie en biologie dÉlocalisÉe. Immuno-analyse & Biologie SpÉcialisÉe 2008; 23: 109-115.
    • (2008) Immuno-analyse & Biologie SpÉcialisée , vol.23 , pp. 109-115
    • Szymanowicz, A.1    Blanc-Bernard, E.2    Roche, C.3
  • 16
    • 4043104115 scopus 로고    scopus 로고
    • ImmunoDip: an improved screening method for microalbuminuria
    • Davidson MB, Bazargan M, Bakris G et al. ImmunoDip: an improved screening method for microalbuminuria. Am J Nephrol 2004; 24: 284-8.
    • (2004) Am J Nephrol , vol.24 , pp. 284-288
    • Davidson, M.B.1    Bazargan, M.2    Bakris, G.3
  • 17
    • 0031716114 scopus 로고    scopus 로고
    • Comparison of instrument-read dipsticks for albumin and creatinine in urine with visual results and quantitative methods
    • Pugia MJ, Lott JA, Luke KE et al. Comparison of instrument-read dipsticks for albumin and creatinine in urine with visual results and quantitative methods. J Clin Lab Anal 1998; 12: 280-4.
    • (1998) J Clin Lab Anal , vol.12 , pp. 280-284
    • Pugia, M.J.1    Lott, J.A.2    Luke, K.E.3
  • 19
    • 20244378912 scopus 로고    scopus 로고
    • Which test to detect microalbuminuria in diabetic patients? A systematic review
    • Ewald B, Attia J. Which test to detect microalbuminuria in diabetic patients? A systematic review. Aust Fam Physician 2004; 33: 565-7, 571.
    • (2004) Aust Fam Physician , vol.33 , pp. 565-571
    • Ewald, B.1    Attia, J.2
  • 20
    • 53749086716 scopus 로고    scopus 로고
    • Albuminuria assessed from first-morning-void urine samples versus 24-hour urine collections as a predictor of cardiovascular morbidity and mortality
    • Lambers Heerspink HJ, Brantsma AH, de Zeeuw D et al. Albuminuria assessed from first-morning-void urine samples versus 24-hour urine collections as a predictor of cardiovascular morbidity and mortality. Am J Epidemiol 2008; 168: 897-905.
    • (2008) Am J Epidemiol , vol.168 , pp. 897-905
    • Heerspink, L.H.J.1    Brantsma, A.H.2    De Zeeuw, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.