메뉴 건너뛰기




Volumn , Issue , 2013, Pages

A thermal imaging based wireless sensor network for automatic water leakage detection in distribution pipes

Author keywords

Automatic water leakage detection; Thermal imaging; Water distribution pipe; Wireless sensor network

Indexed keywords

DEVELOPED COUNTRIES; MANUAL INTERVENTION; SENSOR NETWORK SYSTEMS; THERMAL IMAGING SENSORS; WATER CONTAMINATION; WATER DISTRIBUTION PIPES; WATER LEAKAGE; WATER PIPE NETWORKS;

EID: 84875480941     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CONECCT.2013.6469289     Document Type: Conference Paper
Times cited : (17)

References (22)
  • 2
    • 84875497924 scopus 로고    scopus 로고
    • Review of iron pipe corrosion in drinking water distribution systems
    • L. S. McNeill and M. Edwards, "Review of iron pipe corrosion in drinking water distribution systems," American Water Works Association, pp. 24-35, 2000.
    • (2000) American Water Works Association , pp. 24-35
    • McNeill, L.S.1    Edwards, M.2
  • 4
    • 84875546696 scopus 로고    scopus 로고
    • Leak detection and leak location in underground pipelines
    • A. N. Tafuri, J. J.Yezzi, D. J. Watts, and J. M. Carlyle, "Leak detection and leak location in underground pipelines," DATE, 2009.
    • (2009) DATE
    • Tafuri, A.N.1    Yezzi, J.J.2    Watts, D.J.3    Carlyle, J.M.4
  • 5
    • 84875539156 scopus 로고    scopus 로고
    • Detecting and locating leaks in water distribution polyethylene pipes
    • proceedings of the World Congress on Engineering 2010 Vol II
    • M. Pal, N. Dixon, and J. Flint, "Detecting and locating leaks in water distribution polyethylene pipes," WCE, vol. 1, 2010, proceedings of the World Congress on Engineering 2010 Vol II.
    • (2010) WCE , vol.1
    • Pal, M.1    Dixon, N.2    Flint, J.3
  • 7
    • 84863737710 scopus 로고    scopus 로고
    • Detecting and locating leaks in underground water mains using thermography
    • proceedings of the 26th International Symposium on Automation and Robotics in Construction 2009
    • M. Fahmy, P. Eng., M. ASCE, O. Moselhi, P. Eng, and F. ASCE, "Detecting and locating leaks in underground water mains using thermography," ISARC, pp. 61-67, 2009, proceedings of the 26th International Symposium on Automation and Robotics in Construction 2009.
    • (2009) ISARC , pp. 61-67
    • Fahmy, M.1    Eng, P.2    Asce, M.3    Moselhi, O.4    Eng, P.5    Asce, F.6
  • 8
    • 84875506288 scopus 로고    scopus 로고
    • Detection of water leaks using ground penetrating radar
    • proceedings of the Communication Systems and Networks
    • S. Eyuboglu, H. Mahdi, and H. Al-Shukri, "Detection of water leaks using ground penetrating radar," CSN, 2006, proceedings of the Communication Systems and Networks.
    • (2006) CSN
    • Eyuboglu, S.1    Mahdi, H.2    Al-Shukri, H.3
  • 14
    • 84875513998 scopus 로고    scopus 로고
    • "AA battery," http://en.wikipedia.org/wiki/AAbattery.
    • AA Battery
  • 20
    • 84875488136 scopus 로고    scopus 로고
    • D.-K. Corporation, "STM32L," http://www.digikey.com/product- detail/en/STM32L-DISCOVERY/497-11152-ND/2640507, 2012.
    • (2012) STM32L
    • Corporation, D.-K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.