메뉴 건너뛰기




Volumn 182, Issue , 2013, Pages 53-57

Hydrogen peroxide detection under physiological conditions by Prussian blue stabilized using a polyelectrolyte-surfactant complex matrix

Author keywords

Artificial peroxidase; H2O2 detection; Physiological conditions; Poly(allylamine); Prussian blue; Sodium dodecylsulfate

Indexed keywords

ARTIFICIAL PEROXIDASE; BIOANALYTICAL APPLICATIONS; ELECTROCHEMICAL BEHAVIORS; HYDROGEN PEROXIDE DETECTIONS; PHYSIOLOGICAL CONDITION; POLYALLYLAMINE; POLYELECTROLYTE-SURFACTANT COMPLEXES; PRUSSIAN BLUE;

EID: 84875456630     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.02.081     Document Type: Article
Times cited : (8)

References (27)
  • 1
    • 82555181619 scopus 로고    scopus 로고
    • Recent advances in electrochemical sensing for hydrogen peroxide: A review
    • W. Chen, C. Shu, Q. Ren, W. Wen, and Y. Zhao Recent advances in electrochemical sensing for hydrogen peroxide: a review Analyst 137 2012 49 58
    • (2012) Analyst , vol.137 , pp. 49-58
    • Chen, W.1    Shu, C.2    Ren, Q.3    Wen, W.4    Zhao, Y.5
  • 2
    • 0037420379 scopus 로고    scopus 로고
    • Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors
    • DOI 10.1021/ja028951v
    • J. Wang, M. Musameh, and Y.H. Lin Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors Journal of the American Chemical Society 125 9 2003 2408 2409 (Pubitemid 36512224)
    • (2003) Journal of the American Chemical Society , vol.125 , Issue.9 , pp. 2408-2409
    • Wang, J.1    Musameh, M.2    Lin, Y.3
  • 4
    • 0043131849 scopus 로고    scopus 로고
    • Dispersion of multi-wall carbon nanotubes in polyethylenimine: A new alternative for preparing electrochemical sensors
    • M.D. Rubianes, and G.A. Rivas Dispersion of multi-wall carbon nanotubes in polyethylenimine: a new alternative for preparing electrochemical sensors Electrochemistry Communications 5 2003 689 694
    • (2003) Electrochemistry Communications , vol.5 , pp. 689-694
    • Rubianes, M.D.1    Rivas, G.A.2
  • 5
    • 70349253897 scopus 로고    scopus 로고
    • Characterization of carbon paste electrodes modified with manganese based perovskites-type oxides from the amperometric determination of hydrogen peroxide
    • G.L. Luque, N.F. Ferreyra, A.G. Leyva, and G.A. Rivas Characterization of carbon paste electrodes modified with manganese based perovskites-type oxides from the amperometric determination of hydrogen peroxide Sensors and Actuators B: Chemistry 142 2009 331 336
    • (2009) Sensors and Actuators B: Chemistry , vol.142 , pp. 331-336
    • Luque, G.L.1    Ferreyra, N.F.2    Leyva, A.G.3    Rivas, G.A.4
  • 6
    • 64649106692 scopus 로고    scopus 로고
    • Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene
    • C. Shan, H. Yang, J. Song, D. Han, A. Ivaska, and L. Niu Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene Analytical Chemistry 81 6 2009 2378 2382
    • (2009) Analytical Chemistry , vol.81 , Issue.6 , pp. 2378-2382
    • Shan, C.1    Yang, H.2    Song, J.3    Han, D.4    Ivaska, A.5    Niu, L.6
  • 8
    • 4043050088 scopus 로고    scopus 로고
    • Prussian blue modified glassy carbon electrodes-study on operational stability and its application as a sucrose biosensor
    • B. Haghighi, S. Varma, F.M. Alizadeh Sh, Y. Yigzaw, and L. Gorton Prussian blue modified glassy carbon electrodes-study on operational stability and its application as a sucrose biosensor Talanta 64 2004 3 12
    • (2004) Talanta , vol.64 , pp. 3-12
    • Haghighi, B.1    Varma, S.2    Alizadeh Sh, F.M.3    Yigzaw, Y.4    Gorton, L.5
  • 9
    • 0000797848 scopus 로고
    • Spectroelectrochemistry and electrochemical preparation method of Prussian blue modified electrodes
    • K. Itaya, T. Ataka, and S. Toshima Spectroelectrochemistry and electrochemical preparation method of Prussian blue modified electrodes Journal of the American Chemical Society 104 1982 4767 4772
    • (1982) Journal of the American Chemical Society , vol.104 , pp. 4767-4772
    • Itaya, K.1    Ataka, T.2    Toshima, S.3
  • 10
    • 13244253744 scopus 로고    scopus 로고
    • Synthesis, characterization and immobilization of Prussian blue nanoparticles. A potential tool for biosensing devices
    • DOI 10.1039/b412583e
    • P.A. Fiorito, V.R. Goncales, E.A. Ponzio, and S.I. Córdoba de Torresi Synthesis, characterization and immobilization of Prussian blue nanoparticles. A potential tool for biosensing devices Chemical Communications 2005 366 368 (Pubitemid 40187637)
    • (2005) Chemical Communications , Issue.3 , pp. 366-368
    • Fiorito, P.A.1    Goncales, V.R.2    Ponzio, E.A.3    Cordoba De Torresi, S.I.4
  • 12
    • 78650673074 scopus 로고    scopus 로고
    • An electroactive versatile matrix for the construction of sensors
    • M.L. Cortez, G.A. González, and F. Battaglini An electroactive versatile matrix for the construction of sensors Electroanalysis 23 2011 156 160
    • (2011) Electroanalysis , vol.23 , pp. 156-160
    • Cortez, M.L.1    González, G.A.2    Battaglini, F.3
  • 13
    • 80054683971 scopus 로고    scopus 로고
    • Electrochemical sensing platform based on polyelectrolyte surfactant supramolecular assemblies incorporating carbon nanotubes
    • M.L. Cortez, M. Ceolín, O. Azzaroni, and F. Battaglini Electrochemical sensing platform based on polyelectrolyte surfactant supramolecular assemblies incorporating carbon nanotubes Analytical Chemistry 83 2011 8011 8018
    • (2011) Analytical Chemistry , vol.83 , pp. 8011-8018
    • Cortez, M.L.1    Ceolín, M.2    Azzaroni, O.3    Battaglini, F.4
  • 15
    • 0036856132 scopus 로고    scopus 로고
    • Reversible photocontrollable magnetic vesicles consisting of azobenzene
    • Y. Einaga, T. Yamamoto, T. Sugai, and O. Sato Reversible photocontrollable magnetic vesicles consisting of azobenzene Chemistry of Materials 14 2002 4846 4850
    • (2002) Chemistry of Materials , vol.14 , pp. 4846-4850
    • Einaga, Y.1    Yamamoto, T.2    Sugai, T.3    Sato, O.4
  • 16
    • 79951594249 scopus 로고    scopus 로고
    • Improved sensing in physiological buffers by controlling the nanostructure of Prussian blue films
    • J. Du, Y. Wang, X. Zhou, Z. Xue, X. Liu, K. Sun, and X. Lu Improved sensing in physiological buffers by controlling the nanostructure of Prussian blue films Journal of Physical Chemistry C 114 2010 14786 14793
    • (2010) Journal of Physical Chemistry C , vol.114 , pp. 14786-14793
    • Du, J.1    Wang, Y.2    Zhou, X.3    Xue, Z.4    Liu, X.5    Sun, K.6    Lu, X.7
  • 17
    • 84856112899 scopus 로고    scopus 로고
    • Surfactant-promoted Prussian blue-modified carbon electrodes: Enhacement of electro-deposition step, stabilization, electrochemical properties and application to lactate microbiosensors
    • P. Salazar, M. Martín, R.D. O'Neill, R. Roche, and J.L. González-Mora Surfactant-promoted Prussian blue-modified carbon electrodes: Enhacement of electro-deposition step, stabilization, electrochemical properties and application to lactate microbiosensors Colloids and Surfaces B: Biointerfaces 92 2012 180 189
    • (2012) Colloids and Surfaces B: Biointerfaces , vol.92 , pp. 180-189
    • Salazar, P.1    Martín, M.2    O'Neill, R.D.3    Roche, R.4    González-Mora, J.L.5
  • 18
    • 38349082673 scopus 로고    scopus 로고
    • Disposable gold electrode array for simultaneous electrochemical studies
    • G. Priano, G. Gonzalez, M. Günther, and F. Battaglini Disposable gold electrode array for simultaneous electrochemical studies Electroanalysis 20 2008 91 97
    • (2008) Electroanalysis , vol.20 , pp. 91-97
    • Priano, G.1    Gonzalez, G.2    Günther, M.3    Battaglini, F.4
  • 20
    • 0035839166 scopus 로고    scopus 로고
    • 10 and triiodothyronine
    • DOI 10.1016/S0168-3659(01)00352-2, PII S0168365901003522
    • 10 and triiodothyronine Journal of Controlled Release 75 2001 237 247 (Pubitemid 32727255)
    • (2001) Journal of Controlled Release , vol.75 , Issue.3 , pp. 237-247
    • Thunemann, A.F.1    General, S.2
  • 21
    • 8644286886 scopus 로고    scopus 로고
    • Size and surface effects of Prussian blue nanoparticles protected by organic polymers
    • T. Uemura, M. Ohba, and S. Kitagawa Size and surface effects of Prussian blue nanoparticles protected by organic polymers Inorganic Chemistry 43 2004 7339 7345
    • (2004) Inorganic Chemistry , vol.43 , pp. 7339-7345
    • Uemura, T.1    Ohba, M.2    Kitagawa, S.3
  • 22
    • 34249872162 scopus 로고    scopus 로고
    • Fabrication and electrochemical investigation of layer-by-layer deposited titanium phosphate/Prussian blue composite films
    • DOI 10.1021/la700239r
    • Q. Wang, L. Zhang, L. Qiu, J. Sun, and J. Shen Fabrication electrochemical investigation of layer-by-layer deposited titanium Phosphate/Prussian blue composite film Langmuir 23 2007 6084 6090 (Pubitemid 46868677)
    • (2007) Langmuir , vol.23 , Issue.11 , pp. 6084-6090
    • Wang, Q.1    Zhang, L.2    Qiu, L.3    Sun, J.4    Shen, J.5
  • 23
    • 33845279979 scopus 로고
    • Observations on the composition of Prussian blue films and their electrochemistry
    • C.A. Lundgren, and R.W. Murray Observations on the composition of Prussian blue films and their electrochemistry Inorganic Chemistry 27 1988 933 939
    • (1988) Inorganic Chemistry , vol.27 , pp. 933-939
    • Lundgren, C.A.1    Murray, R.W.2
  • 24
    • 58549097434 scopus 로고    scopus 로고
    • A sensitivity-controlled hydrogen peroxide sensor base don self-assembled Prussian blue modified electrode
    • Y. Liu, Z. Chu, and W. Jin A sensitivity-controlled hydrogen peroxide sensor base don self-assembled Prussian blue modified electrode Electrochemistry Communications 11 2009 484 487
    • (2009) Electrochemistry Communications , vol.11 , pp. 484-487
    • Liu, Y.1    Chu, Z.2    Jin, W.3
  • 25
    • 29944441490 scopus 로고    scopus 로고
    • Prussian blue-glutamate oxidase modified glassy carbon electrode: A sensitive L-glutamate and β-N-oxalyl-α,β-diaminopropionic acid (β-ODAP) sensor
    • DOI 10.1016/j.aca.2005.09.047, PII S0003267005016193
    • S. Varma, Y. Yigzaw, and L. Gorton Prussian blue-glutamate oxidase modified glassy carbon electrode: a sensitive L-glutamate and β-N-oxalyl-α,β-diaminopropionic acid (β-ODAP) sensor Analytica Chimica Acta 556 2006 319 325 (Pubitemid 43042552)
    • (2006) Analytica Chimica Acta , vol.556 , Issue.2 , pp. 319-325
    • Varma, S.1    Yigzaw, Y.2    Gorton, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.