메뉴 건너뛰기




Volumn 39, Issue 4, 2013, Pages 501-510

Optical patient interface in femtosecond laser-assisted cataract surgery: Contact corneal applanation versus liquid immersion

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; CAPSULOTOMY; CATARACT EXTRACTION; CONTROLLED STUDY; CURVED CONTACT LENS INTERFACE; EYE MOVEMENT; FEMTOSECOND LASER; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; LIQUID OPTICAL IMMERSION INTERFACE; NONHUMAN; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 84875447283     PISSN: 08863350     EISSN: 18734502     Source Type: Journal    
DOI: 10.1016/j.jcrs.2013.01.021     Document Type: Article
Times cited : (105)

References (13)
  • 1
    • 33745216937 scopus 로고    scopus 로고
    • Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes
    • J.H. Talamo, J. Meltzer, and J. Gardner Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes J Refract Surg 22 2006 556 561
    • (2006) J Refract Surg , vol.22 , pp. 556-561
    • Talamo, J.H.1    Meltzer, J.2    Gardner, J.3
  • 2
    • 16344380948 scopus 로고    scopus 로고
    • Experimental observation of intraocular pressure changes during microkeratome suctioning in laser in situ keratomileusis
    • H. Bissen-Miyajima, S. Suzuki, Y. Ohashi, and K. Minami Experimental observation of intraocular pressure changes during microkeratome suctioning in laser in situ keratomileusis J Cataract Refract Surg 31 2005 590 594
    • (2005) J Cataract Refract Surg , vol.31 , pp. 590-594
    • Bissen-Miyajima, H.1    Suzuki, S.2    Ohashi, Y.3    Minami, K.4
  • 3
    • 34247536364 scopus 로고    scopus 로고
    • Continuous intraocular pressure recordings during lamellar microkeratotomy of enucleated human eyes
    • J.C. Bradley, D.L. McCartney, and G.A. Craenen Continuous intraocular pressure recordings during lamellar microkeratotomy of enucleated human eyes J Cataract Refract Surg 33 2007 869 872
    • (2007) J Cataract Refract Surg , vol.33 , pp. 869-872
    • Bradley, J.C.1    McCartney, D.L.2    Craenen, G.A.3
  • 5
    • 75649104973 scopus 로고    scopus 로고
    • Ocular blood-flow hemodynamics before and after application of a laser in situ keratomileusis ring
    • M.L. Conway, M. Wevill, A. Benavente-Perez, and S.L. Hosking Ocular blood-flow hemodynamics before and after application of a laser in situ keratomileusis ring J Cataract Refract Surg 36 2010 268 272
    • (2010) J Cataract Refract Surg , vol.36 , pp. 268-272
    • Conway, M.L.1    Wevill, M.2    Benavente-Perez, A.3    Hosking, S.L.4
  • 6
    • 77953655708 scopus 로고    scopus 로고
    • Evaluation of the need to discontinue antiplatelet and anticoagulant medications before cataract surgery
    • H. Kobayashi Evaluation of the need to discontinue antiplatelet and anticoagulant medications before cataract surgery J Cataract Refract Surg 36 2010 1115 1119
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1115-1119
    • Kobayashi, H.1
  • 11
    • 75949106260 scopus 로고    scopus 로고
    • Wave aberration of human eyes and new descriptors of image optical quality and visual performance
    • M. Lombardo, and G. Lombardo Wave aberration of human eyes and new descriptors of image optical quality and visual performance J Cataract Refract Surg 36 2010 313 331
    • (2010) J Cataract Refract Surg , vol.36 , pp. 313-331
    • Lombardo, M.1    Lombardo, G.2
  • 13
    • 84870983677 scopus 로고    scopus 로고
    • Intraocular pressure variation during femtosecond laser-assisted cataract surgery using a fluid-filled interface
    • T. Schultz, I. Conrad-Hengerer, F.H. Hengerer, and H.B. Dick Intraocular pressure variation during femtosecond laser-assisted cataract surgery using a fluid-filled interface J Cataract Refract Surg 39 2013 22 27
    • (2013) J Cataract Refract Surg , vol.39 , pp. 22-27
    • Schultz, T.1    Conrad-Hengerer, I.2    Hengerer, F.H.3    Dick, H.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.