Volumn 94, Issue 4, 2013, Pages 782-787

Impact of hydrophilic catheters on urinary tract infections in people with spinal cord injury: Systematic review and meta-analysis of randomized controlled trials

Author keywords

Catheter; Meta analysis; Randomized controlled trial; Rehabilitation; Spinal cord injuries; Urinary tract infections

Indexed keywords

CATHETER; DISEASE COURSE; HEMATURIA; HUMAN; HYDROPHILIC CATHETER; META ANALYSIS; MORBIDITY; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; SPINAL CORD INJURY; SYSTEMATIC REVIEW; THERAPY EFFECT; URINARY TRACT INFECTION;

EID: 84875420648     PISSN: 00039993     EISSN: 1532821X     Source Type: Journal    
DOI: 10.1016/j.apmr.2012.11.010     Document Type: Review
Times cited : (73)

References (30)
  • 1
    • 0141627487 scopus 로고    scopus 로고
    • Management of urinary tract infection in patients with spinal cord injuries
    • M.E. Garcia Leoni, and A. Esclarin De Ruz Management of urinary tract infection in patients with spinal cord injuries Clin Microbiol Infect 9 2003 780 785
    • (2003) Clin Microbiol Infect , vol.9 , pp. 780-785
    • Garcia Leoni, M.E.1    Esclarin De Ruz, A.2
  • 2
    • 0037043283 scopus 로고    scopus 로고
    • Pathogenesis of bacteriuria and infection in the spinal cord injured patient
    • M.B. Siroky Pathogenesis of bacteriuria and infection in the spinal cord injured patient Am J Med 113 Suppl 1A 2002 S67 S79
    • (2002) Am J Med , vol.113 , Issue.SUPPL. 1A
    • Siroky, M.B.1
  • 3
    • 0031962546 scopus 로고    scopus 로고
    • Clean intermittent catheterization and prevention of renal disease in spinal cord injury patients
    • A. Giannantoni, G. Scivoletto, and S.M. Di Stasi Clean intermittent catheterization and prevention of renal disease in spinal cord injury patients Spinal Cord 36 1998 29 32
    • (1998) Spinal Cord , vol.36 , pp. 29-32
    • Giannantoni, A.1    Scivoletto, G.2    Di Stasi, S.M.3
  • 4
    • 0033254883 scopus 로고    scopus 로고
    • The development of bacterial biofilms on indwelling catheters
    • N.S. Morris, D.J. Stickler, and R.J. Mclean The development of bacterial biofilms on indwelling catheters World J Urol 17 1999 345 350
    • (1999) World J Urol , vol.17 , pp. 345-350
    • Morris, N.S.1    Stickler, D.J.2    McLean, R.J.3
  • 5
    • 0028858840 scopus 로고
    • Clean intermittent catheterization in spinal cord injury patients: Long-term follow up of a hydrophilic low friction technique
    • L. Waller, O. Jonsson, L. Norlén, and L. Sullivan Clean intermittent catheterization in spinal cord injury patients: long-term follow up of a hydrophilic low friction technique J Urol 153 1995 345 348
    • (1995) J Urol , vol.153 , pp. 345-348
    • Waller, L.1    Jonsson, O.2    Norlén, L.3    Sullivan, L.4
  • 6
    • 0028285772 scopus 로고
    • Urethral cytology in spinal cord injury patients performing intermittent catheterization
    • S. Vaidyanathan, B.M. Soni, S. Dundas, and K.R. Krishnan Urethral cytology in spinal cord injury patients performing intermittent catheterization Paraplegia 32 1994 493 500
    • (1994) Paraplegia , vol.32 , pp. 493-500
    • Vaidyanathan, S.1    Soni, B.M.2    Dundas, S.3    Krishnan, K.R.4
  • 7
    • 0028798413 scopus 로고
    • Patient satisfaction and the LoFric catheter for clean intermittent catheterization
    • A.C. Diokno, B.A. Mitchell, A.J. Nash, and J.A. Kimbrough Patient satisfaction and the LoFric catheter for clean intermittent catheterization J Urol 153 1995 349 351
    • (1995) J Urol , vol.153 , pp. 349-351
    • Diokno, A.C.1    Mitchell, B.A.2    Nash, A.J.3    Kimbrough, J.A.4
  • 8
    • 78651105285 scopus 로고    scopus 로고
    • Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention
    • E. Chartier-Kastler, and P. Denys Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention Neurourol Urodyn 30 2011 21 31
    • (2011) Neurourol Urodyn , vol.30 , pp. 21-31
    • Chartier-Kastler, E.1    Denys, P.2
  • 9
    • 27844511641 scopus 로고    scopus 로고
    • Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: A prospective, randomized, participant-blinded, crossover study of three different types of catheters
    • J. Stensballe, D. Looms, P.N. Nielsen, and M. Tvede Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomized, participant-blinded, crossover study of three different types of catheters Eur Urol 48 2005 978 983
    • (2005) Eur Urol , vol.48 , pp. 978-983
    • Stensballe, J.1    Looms, D.2    Nielsen, P.N.3    Tvede, M.4
  • 10
    • 0029913536 scopus 로고    scopus 로고
    • Clean intermittent catheterization in boys using the LoFric catheter
    • R.S. Sutherland, B.A. Kogan, L.S. Baskin, and R.A. Mevorach Clean intermittent catheterization in boys using the LoFric catheter J Urol 156 1996 2041 2043
    • (1996) J Urol , vol.156 , pp. 2041-2043
    • Sutherland, R.S.1    Kogan, B.A.2    Baskin, L.S.3    Mevorach, R.A.4
  • 12
    • 34547645613 scopus 로고    scopus 로고
    • Effect of short-term exposure to two hydrophilic-coated and one gel pre-lubricated urinary catheters on sperm vitality, motility and kinematics in vitro
    • J. Auger, R. Rihaoui, N. François, and F. Eustache Effect of short-term exposure to two hydrophilic-coated and one gel pre-lubricated urinary catheters on sperm vitality, motility and kinematics in vitro Minerva Urol Nefrol 59 2007 115 124
    • (2007) Minerva Urol Nefrol , vol.59 , pp. 115-124
    • Auger, J.1    Rihaoui, R.2    François, N.3    Eustache, F.4
  • 13
    • 0034918038 scopus 로고    scopus 로고
    • Comparison of 3 self-lubricated urethral catheters: Prospective study on 27 patients
    • B. Mauroy, R. Soret, J.L. Bonnal, and J.C. Fantoni Comparison of 3 self-lubricated urethral catheters: prospective study on 27 patients Ann Urol (Paris) 35 2001 223 228
    • (2001) Ann Urol (Paris) , vol.35 , pp. 223-228
    • Mauroy, B.1    Soret, R.2    Bonnal, J.L.3    Fantoni, J.C.4
  • 14
    • 0035825956 scopus 로고    scopus 로고
    • Evaluation of two coated catheters in intermittent self-catheterization
    • G. Pascoe, and S. Clovis Evaluation of two coated catheters in intermittent self-catheterization Br J Nurs 10 2001 325 329
    • (2001) Br J Nurs , vol.10 , pp. 325-329
    • Pascoe, G.1    Clovis, S.2
  • 16
    • 33750604608 scopus 로고    scopus 로고
    • Impact of StatLock securing device on symptomatic catheter-related urinary tract infection: A prospective, randomized, multicenter clinical trial
    • R.O. Darouiche, L. Goetz, T. Kaldis, C. Cerra-Stewart, A. AlSharif, and M. Priebe Impact of StatLock securing device on symptomatic catheter-related urinary tract infection: a prospective, randomized, multicenter clinical trial Am J Infect Control 34 2006 555 560
    • (2006) Am J Infect Control , vol.34 , pp. 555-560
    • Darouiche, R.O.1    Goetz, L.2    Kaldis, T.3    Cerra-Stewart, C.4    Alsharif, A.5    Priebe, M.6
  • 17
    • 79959896871 scopus 로고    scopus 로고
    • Safety of a new compact catheter for men with neurogenic bladder dysfunction: A randomized, crossover and open-labeled study
    • E. Chartier-Kastler, I. Lauge, A. Ruffion, D. Goossens, K. Charvier, and F. Biering-Sørensen Safety of a new compact catheter for men with neurogenic bladder dysfunction: a randomized, crossover and open-labeled study Spinal Cord 49 2011 844 850
    • (2011) Spinal Cord , vol.49 , pp. 844-850
    • Chartier-Kastler, E.1    Lauge, I.2    Ruffion, A.3    Goossens, D.4    Charvier, K.5    Biering-Sørensen, F.6
  • 18
    • 79957867370 scopus 로고    scopus 로고
    • Comparison of the use of conventional, hydrophilic and gel-lubricated catheters with regard to urethral micro trauma, urinary system infection, and patient satisfaction in patients with spinal cord injury: A randomized controlled study
    • S. Sarica, Y. Akkoc, H. Karapolar, and H. Aktuq Comparison of the use of conventional, hydrophilic and gel-lubricated catheters with regard to urethral micro trauma, urinary system infection, and patient satisfaction in patients with spinal cord injury: a randomized controlled study Eur J Phys Rehabil Med 46 2010 473 479
    • (2010) Eur J Phys Rehabil Med , vol.46 , pp. 473-479
    • Sarica, S.1    Akkoc, Y.2    Karapolar, H.3    Aktuq, H.4
  • 19
    • 79955804187 scopus 로고    scopus 로고
    • Intermittent catheterization with a hydrophilic-coated catheter delays urinary tract infections in acute spinal cord injury: A prospective, randomized, multicenter trial
    • D.D. Cardenas, K.N. Moore, and A. Dannels-McClure Intermittent catheterization with a hydrophilic-coated catheter delays urinary tract infections in acute spinal cord injury: a prospective, randomized, multicenter trial PM R 3 2011 408 417
    • (2011) PM R , vol.3 , pp. 408-417
    • Cardenas, D.D.1    Moore, K.N.2    Dannels-Mcclure, A.3
  • 20
    • 70350482198 scopus 로고    scopus 로고
    • Hydrophilic catheters versus noncoated catheters for reducing the incidence of urinary tract infections: A randomized controlled trial
    • D.D. Cardenas, and J.M. Hoffman Hydrophilic catheters versus noncoated catheters for reducing the incidence of urinary tract infections: a randomized controlled trial Arch Phys Med Rehabil 90 2009 1668 1671
    • (2009) Arch Phys Med Rehabil , vol.90 , pp. 1668-1671
    • Cardenas, D.D.1    Hoffman, J.M.2
  • 21
    • 27844551385 scopus 로고    scopus 로고
    • Intermittent catheterization with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients: A prospective randomized parallel comparative trial
    • D.J. De Ridder, K. Everaert, and L.G. Fernández Intermittent catheterization with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients: a prospective randomized parallel comparative trial Eur Urol 48 2005 991 995
    • (2005) Eur Urol , vol.48 , pp. 991-995
    • De Ridder, D.J.1    Everaert, K.2    Fernández, L.G.3
  • 22
    • 0037365802 scopus 로고    scopus 로고
    • A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization
    • J.M. Vapnek, F.M. Maynard, and J. Kim A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization J Urol 169 2003 994 998
    • (2003) J Urol , vol.169 , pp. 994-998
    • Vapnek, J.M.1    Maynard, F.M.2    Kim, J.3
  • 23
    • 79953769654 scopus 로고    scopus 로고
    • Reprint-preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
    • D. Moher, A. Liberati, J. Tetzlaff, and D.G. Altman Reprint-preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement Phys Ther 89 2009 873 880
    • (2009) Phys Ther , vol.89 , pp. 873-880
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3    Altman, D.G.4
  • 24
    • 84942475903 scopus 로고
    • The Cochrane Collaboration. Preparing, maintaining, and disseminating systematic reviews of the effects of health care
    • L. Bero, and D. Rennie The Cochrane Collaboration. Preparing, maintaining, and disseminating systematic reviews of the effects of health care JAMA 274 1995 1935 1938
    • (1995) JAMA , vol.274 , pp. 1935-1938
    • Bero, L.1    Rennie, D.2
  • 25
    • 44449164571 scopus 로고    scopus 로고
    • CDC/NHSN surveillance definition of health care associated infection and criteria for specific types of infections in the acute care setting
    • T.C. Horan, M. Andrus, and M.A. Dudeck CDC/NHSN surveillance definition of health care associated infection and criteria for specific types of infections in the acute care setting Am J Infect Control 36 2008 309 332
    • (2008) Am J Infect Control , vol.36 , pp. 309-332
    • Horan, T.C.1    Andrus, M.2    Dudeck, M.A.3
  • 26
    • 0029914622 scopus 로고    scopus 로고
    • Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
    • A.R. Jadad, R.A. Moore, and D. Carroll Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17 1996 1 12
    • (1996) Control Clin Trials , vol.17 , pp. 1-12
    • Jadad, A.R.1    Moore, R.A.2    Carroll, D.3
  • 28
    • 0030922816 scopus 로고    scopus 로고
    • Bias in meta-analysis detected by a simple, graphical test
    • M. Egger, G. Davey Smith, M. Schneider, and C. Minder Bias in meta-analysis detected by a simple, graphical test BMJ 315 1997 629 634
    • (1997) BMJ , vol.315 , pp. 629-634
    • Egger, M.1    Davey Smith, G.2    Schneider, M.3    Minder, C.4
  • 29
    • 0028659004 scopus 로고
    • Operating characteristics of a rank correlation test for publication bias
    • C.B. Begg, and M. Mazumdar Operating characteristics of a rank correlation test for publication bias Biometrics 50 1994 1088 1101
    • (1994) Biometrics , vol.50 , pp. 1088-1101
    • Begg, C.B.1    Mazumdar, M.2
  • 30
    • 0015307333 scopus 로고
    • Clean intermittent self-catheterization in the treatment of urinary tract disease
    • J. Lapides, A.C. Diokno, S.J. Silber, and B.S. Lowe Clean intermittent self-catheterization in the treatment of urinary tract disease J Urol 107 1972 458 461
    • (1972) J Urol , vol.107 , pp. 458-461
    • Lapides, J.1    Diokno, A.C.2    Silber, S.J.3    Lowe, B.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.