메뉴 건너뛰기




Volumn 45, Issue 4, 2013, Pages 315-323

Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking

Author keywords

Abdominal aortic aneurysm; Rupture; Speckle tracking; Strain; Three dimensional imaging; Ultrasonography

Indexed keywords

SILICONE;

EID: 84875265034     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2013.01.004     Document Type: Article
Times cited : (46)

References (24)
  • 1
    • 23244466272 scopus 로고    scopus 로고
    • Biomechanical determinants of abdominal aortic aneurysm rupture
    • D.A. Vorp, and J.P. Vande Geest Biomechanical determinants of abdominal aortic aneurysm rupture Arterioscler Thromb Vasc Biol 25 8 2005 Aug 1558 1566
    • (2005) Arterioscler Thromb Vasc Biol , vol.25 , Issue.8 , pp. 1558-1566
    • Vorp, D.A.1    Vande Geest, J.P.2
  • 2
    • 0027512521 scopus 로고
    • Ruptured mesenteric artery aneurysm in a patient with alpha 1-antitrypsin deficiency: Etiologic implications
    • M.B. Mitchell, O.J. McAnena, and R.B. Rutherford Ruptured mesenteric artery aneurysm in a patient with alpha 1-antitrypsin deficiency: etiologic implications J Vasc Surg 17 2 1993 Feb 420 424
    • (1993) J Vasc Surg , vol.17 , Issue.2 , pp. 420-424
    • Mitchell, M.B.1    McAnena, O.J.2    Rutherford, R.B.3
  • 3
    • 18144368061 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm
    • N. Sakalihasan, R. Limet, and O.D. Defawe Abdominal aortic aneurysm Lancet 365 9470 2005 Apr 30-May 6 1577 1589
    • (2005) Lancet , vol.6 , Issue.9470 , pp. 1577-1589
    • Sakalihasan, N.1    Limet, R.2    Defawe, O.D.3
  • 4
    • 0037046644 scopus 로고    scopus 로고
    • Immediate repair compared with surveillance of small abdominal aortic aneurysms
    • F.A. Lederle, S.E. Wilson, G.R. Johnson, D.B. Reinke, F.N. Littooy, and C.W. Acher Immediate repair compared with surveillance of small abdominal aortic aneurysms N Engl J Med 346 19 2002 May 9 1437 1444
    • (2002) N Engl J Med , vol.346 , Issue.19 , pp. 1437-1444
    • Lederle, F.A.1    Wilson, S.E.2    Johnson, G.R.3    Reinke, D.B.4    Littooy, F.N.5    Acher, C.W.6
  • 5
    • 17544398231 scopus 로고    scopus 로고
    • UK small aneurysms trial
    • [Author reply 9]
    • R.A. Scott UK small aneurysms trial Lancet 353 9150 1999 Jan 30 408 [Author reply 9]
    • (1999) Lancet , vol.353 , Issue.9150 , pp. 408
    • Scott, R.A.1
  • 6
    • 0026566154 scopus 로고
    • Diameter and compliance in the male human abdominal aorta: Influence of age and aortic aneurysm
    • T. Lanne, B. Sonesson, D. Bergqvist, H. Bengtsson, and D. Gustafsson Diameter and compliance in the male human abdominal aorta: influence of age and aortic aneurysm Eur J Vasc Surg 6 2 1992 Mar 178 184
    • (1992) Eur J Vasc Surg , vol.6 , Issue.2 , pp. 178-184
    • Lanne, T.1    Sonesson, B.2    Bergqvist, D.3    Bengtsson, H.4    Gustafsson, D.5
  • 8
    • 84857128986 scopus 로고    scopus 로고
    • Use of regional mechanical properties of abdominal aortic aneurysms to advance finite element modeling of rupture risk
    • A.P. Tierney, A. Callanan, and T.M. McGloughlin Use of regional mechanical properties of abdominal aortic aneurysms to advance finite element modeling of rupture risk J Endovasc Ther 19 1 2012 Feb 100 114
    • (2012) J Endovasc Ther , vol.19 , Issue.1 , pp. 100-114
    • Tierney, A.P.1    Callanan, A.2    McGloughlin, T.M.3
  • 9
    • 0036246185 scopus 로고    scopus 로고
    • Clinical applications of arterial stiffness; Definitions and reference values
    • M.F. O'Rourke, J.A. Staessen, C. Vlachopoulos, D. Duprez, and G.E. Plante Clinical applications of arterial stiffness; definitions and reference values Am J Hypertens 15 5 2002 May 426 444
    • (2002) Am J Hypertens , vol.15 , Issue.5 , pp. 426-444
    • O'Rourke, M.F.1    Staessen, J.A.2    Vlachopoulos, C.3    Duprez, D.4    Plante, G.E.5
  • 11
    • 80053044865 scopus 로고    scopus 로고
    • Echocardiographic assessment of myocardial strain
    • J. Gorcsan 3rd, and H. Tanaka Echocardiographic assessment of myocardial strain J Am Coll Cardiol 58 14 2011 Sep 27 1401 1413
    • (2011) J Am Coll Cardiol , vol.58 , Issue.14 , pp. 1401-1413
    • Gorcsan III, J.1    Tanaka, H.2
  • 12
    • 23844482154 scopus 로고    scopus 로고
    • Real-time three-dimensional echocardiography: A novel technique to quantify global left ventricular mechanical dyssynchrony
    • S. Kapetanakis, M.T. Kearney, A. Siva, N. Gall, M. Cooklin, and M.J. Monaghan Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony Circulation 112 7 2005 Aug 16 992 1000
    • (2005) Circulation , vol.112 , Issue.7 , pp. 992-1000
    • Kapetanakis, S.1    Kearney, M.T.2    Siva, A.3    Gall, N.4    Cooklin, M.5    Monaghan, M.J.6
  • 13
    • 73449110253 scopus 로고    scopus 로고
    • Validation of 3-dimensional speckle tracking imaging to quantify regional myocardial deformation
    • Y. Seo, T. Ishizu, Y. Enomoto, H. Sugimori, M. Yamamoto, and T. Machino Validation of 3-dimensional speckle tracking imaging to quantify regional myocardial deformation Circ Cardiovasc Imaging 2 6 2009 Nov 451 459
    • (2009) Circ Cardiovasc Imaging , vol.2 , Issue.6 , pp. 451-459
    • Seo, Y.1    Ishizu, T.2    Enomoto, Y.3    Sugimori, H.4    Yamamoto, M.5    MacHino, T.6
  • 14
    • 0028088501 scopus 로고
    • A compliant tubular device to study the influences of wall strain and fluid shear stress on cells of the vascular wall
    • A. Benbrahim, G.J. L'Italien, B.B. Milinazzo, D.F. Warnock, S. Dhara, and J.P. Gertler A compliant tubular device to study the influences of wall strain and fluid shear stress on cells of the vascular wall J Vasc Surg 20 2 1994 Aug 184 194
    • (1994) J Vasc Surg , vol.20 , Issue.2 , pp. 184-194
    • Benbrahim, A.1    L'Italien, G.J.2    Milinazzo, B.B.3    Warnock, D.F.4    Dhara, S.5    Gertler, J.P.6
  • 15
    • 0742287082 scopus 로고    scopus 로고
    • Rotational in vitro compliance measurement of diverse anastomotic configurations: A tool for anastomotic engineering
    • P. Knez, K. Nelson, M. Hakimi, J. Al-Haidary, C. Schneider, and T. Schmitz-Rixen Rotational in vitro compliance measurement of diverse anastomotic configurations: a tool for anastomotic engineering J Biomech 37 3 2004 Mar 275 280
    • (2004) J Biomech , vol.37 , Issue.3 , pp. 275-280
    • Knez, P.1    Nelson, K.2    Hakimi, M.3    Al-Haidary, J.4    Schneider, C.5    Schmitz-Rixen, T.6
  • 16
    • 0017276780 scopus 로고
    • A noncontact method for three-dimensional analysis of vascular elasticity in vivo and in vitro
    • K. Fronek, G. Schmid-Schoenbein, and Y.C. Fung A noncontact method for three-dimensional analysis of vascular elasticity in vivo and in vitro J Appl Physiol 40 4 1976 Apr 634 637
    • (1976) J Appl Physiol , vol.40 , Issue.4 , pp. 634-637
    • Fronek, K.1    Schmid-Schoenbein, G.2    Fung, Y.C.3
  • 18
  • 19
    • 0037285590 scopus 로고    scopus 로고
    • The relationship between aortic wall distensibility and rupture of infrarenal abdominal aortic aneurysm
    • K.A. Wilson, A.J. Lee, P.R. Hoskins, F.G. Fowkes, C.V. Ruckley, and A.W. Bradbury The relationship between aortic wall distensibility and rupture of infrarenal abdominal aortic aneurysm J Vasc Surg 37 1 2003 Jan 112 117
    • (2003) J Vasc Surg , vol.37 , Issue.1 , pp. 112-117
    • Wilson, K.A.1    Lee, A.J.2    Hoskins, P.R.3    Fowkes, F.G.4    Ruckley, C.V.5    Bradbury, A.W.6
  • 20
    • 76849088916 scopus 로고    scopus 로고
    • A tutorial on ultrasonic physics and imaging techniques
    • M. Halliwell A tutorial on ultrasonic physics and imaging techniques Proc Inst Mech Eng H 224 2 2010 127 142
    • (2010) Proc Inst Mech Eng H , vol.224 , Issue.2 , pp. 127-142
    • Halliwell, M.1
  • 21
    • 33644858502 scopus 로고    scopus 로고
    • Matrix metalloproteinase-8 and -9 are increased at the site of abdominal aortic aneurysm rupture
    • W.R. Wilson, M. Anderton, E.C. Schwalbe, J.L. Jones, P.N. Furness, and P.R. Bell Matrix metalloproteinase-8 and -9 are increased at the site of abdominal aortic aneurysm rupture Circulation 113 3 2006 Jan 24 438 445
    • (2006) Circulation , vol.113 , Issue.3 , pp. 438-445
    • Wilson, W.R.1    Anderton, M.2    Schwalbe, E.C.3    Jones, J.L.4    Furness, P.N.5    Bell, P.R.6
  • 22
    • 47249164675 scopus 로고    scopus 로고
    • Increased 18F-fluorodeoxyglucose uptake in abdominal aortic aneurysms in positron emission/computed tomography is associated with inflammation, aortic wall instability, and acute symptoms
    • [Discussion 24]
    • C. Reeps, M. Essler, J. Pelisek, S. Seidl, H.H. Eckstein, and B.J. Krause Increased 18F-fluorodeoxyglucose uptake in abdominal aortic aneurysms in positron emission/computed tomography is associated with inflammation, aortic wall instability, and acute symptoms J Vasc Surg 48 2 2008 Aug 417 423 [Discussion 24]
    • (2008) J Vasc Surg , vol.48 , Issue.2 , pp. 417-423
    • Reeps, C.1    Essler, M.2    Pelisek, J.3    Seidl, S.4    Eckstein, H.H.5    Krause, B.J.6
  • 23
    • 0033374741 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm wall mechanics and their relation to risk of rupture
    • B. Sonesson, T. Sandgren, and T. Lanne Abdominal aortic aneurysm wall mechanics and their relation to risk of rupture Eur J Vasc Endovasc Surg 18 6 1999 Dec 487 493
    • (1999) Eur J Vasc Endovasc Surg , vol.18 , Issue.6 , pp. 487-493
    • Sonesson, B.1    Sandgren, T.2    Lanne, T.3
  • 24
    • 0037382231 scopus 로고    scopus 로고
    • Prediction of rupture risk in abdominal aortic aneurysm during observation: Wall stress versus diameter
    • M.F. Fillinger, S.P. Marra, M.L. Raghavan, and F.E. Kennedy Prediction of rupture risk in abdominal aortic aneurysm during observation: wall stress versus diameter J Vasc Surg 37 4 2003 Apr 724 732
    • (2003) J Vasc Surg , vol.37 , Issue.4 , pp. 724-732
    • Fillinger, M.F.1    Marra, S.P.2    Raghavan, M.L.3    Kennedy, F.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.