메뉴 건너뛰기




Volumn 31, Issue 5, 2013, Pages 814-820

Statins may reduce femoral osteolysis in patients with total Hip arthroplasty

Author keywords

osteolysis; statins; total hip arthroplasty

Indexed keywords

HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR;

EID: 84875225066     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.22262     Document Type: Article
Times cited : (13)

References (33)
  • 2
    • 35448944365 scopus 로고    scopus 로고
    • The operation of the century: Total hip replacement
    • Learmonth ID, Young C, Rorabeck C., 2007. The operation of the century: total hip replacement. Lancet 370: 1508-1519.
    • (2007) Lancet , vol.370 , pp. 1508-1519
    • Learmonth, I.D.1    Young, C.2    Rorabeck, C.3
  • 3
    • 32544454827 scopus 로고    scopus 로고
    • Total joint replacement in osteoarthritis
    • Katz JN., 2006. Total joint replacement in osteoarthritis. Best Pract Res Clin Rheumatol 20: 145-153.
    • (2006) Best Pract Res Clin Rheumatol , vol.20 , pp. 145-153
    • Katz, J.N.1
  • 4
    • 33645776769 scopus 로고    scopus 로고
    • Aseptic loosening, not only a question of wear: A review of different theories
    • Sundfeldt M, Carlsson LV, Johansson CB, et al. 2006. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 77: 177-197.
    • (2006) Acta Orthop , vol.77 , pp. 177-197
    • Sundfeldt, M.1    Carlsson, L.V.2    Johansson, C.B.3
  • 6
    • 33746223260 scopus 로고    scopus 로고
    • Use of bisphosphonates to improve the durability of total joint replacements
    • Shanbhag AS., 2006. Use of bisphosphonates to improve the durability of total joint replacements. J Am Acad Orthop Surg 14: 215-225.
    • (2006) J Am Acad Orthop Surg , vol.14 , pp. 215-225
    • Shanbhag, A.S.1
  • 7
    • 34249285919 scopus 로고    scopus 로고
    • Anabolic effects of bisphosphonates on peri-implant bone stock
    • von Knoch F, Eckhardt C, Alabre CI, et al. 2007. Anabolic effects of bisphosphonates on peri-implant bone stock. Biomaterials 28: 3549-3559.
    • (2007) Biomaterials , vol.28 , pp. 3549-3559
    • Von Knoch, F.1    Eckhardt, C.2    Alabre, C.I.3
  • 8
    • 77950532562 scopus 로고    scopus 로고
    • Postoperative use of bisphosphonates and risk of revision after primary total hip arthroplasty: A nationwide population-based study
    • Thillemann TM, Pedersen AB, Mehnert F, et al. 2010. Postoperative use of bisphosphonates and risk of revision after primary total hip arthroplasty: a nationwide population-based study. Bone 46: 946-951.
    • (2010) Bone , vol.46 , pp. 946-951
    • Thillemann, T.M.1    Pedersen, A.B.2    Mehnert, F.3
  • 9
    • 83255193890 scopus 로고    scopus 로고
    • Effects on 11-year mortality and morbidity of lowering LDL cholesterol with simvastatin for about 5 years in 20536 high-risk individuals: A randomised controlled trial
    • HPSC
    • HPSC. 2011. Effects on 11-year mortality and morbidity of lowering LDL cholesterol with simvastatin for about 5 years in 20536 high-risk individuals: a randomised controlled trial. Lancet 10: 2013-2020.
    • (2011) Lancet , vol.10 , pp. 2013-2020
  • 10
    • 79953050609 scopus 로고    scopus 로고
    • Statins and the joint: Multiple targets for a global protection
    • Lazzerini PE, Capecchi PL, Selvi E, et al. 2011. Statins and the joint: multiple targets for a global protection ? Semin Arthritis Rheum 40: 430-446.
    • (2011) Semin Arthritis Rheum , vol.40 , pp. 430-446
    • Lazzerini, P.E.1    Capecchi, P.L.2    Selvi, E.3
  • 11
    • 39449135402 scopus 로고    scopus 로고
    • Statins attenuate polymethylmethacrylate-mediated monocyte activation
    • Laing AJ, Dillon JP, Mulhall KJ, et al. 2008. Statins attenuate polymethylmethacrylate-mediated monocyte activation. Acta Orthop 79: 134-140.
    • (2008) Acta Orthop , vol.79 , pp. 134-140
    • Laing, A.J.1    Dillon, J.P.2    Mulhall, K.J.3
  • 12
    • 11144298577 scopus 로고    scopus 로고
    • The effect of simvastatin on polyethylene particle-induced osteolysis
    • von Knoch F, Heckelei A, Wedemeyer C, et al. 2005. The effect of simvastatin on polyethylene particle-induced osteolysis. Biomaterials 26: 3549-3555.
    • (2005) Biomaterials , vol.26 , pp. 3549-3555
    • Von Knoch, F.1    Heckelei, A.2    Wedemeyer, C.3
  • 13
    • 80755163519 scopus 로고    scopus 로고
    • Effects of simvastatin on osseointegration in a canine total hip arthroplasty model: An experimental study
    • Yin H, Li J, Yu X, et al. 2011. Effects of simvastatin on osseointegration in a canine total hip arthroplasty model: an experimental study. J Arthroplasty 26: 1534-1539.
    • (2011) J Arthroplasty , vol.26 , pp. 1534-1539
    • Yin, H.1    Li, J.2    Yu, X.3
  • 14
    • 77952516350 scopus 로고    scopus 로고
    • The risk of revision after primary total hip arthroplasty among statin users: A nationwide population-based nested case-control study
    • Thillemann TM, Pedersen AB, Mehnert F, et al. 2010. The risk of revision after primary total hip arthroplasty among statin users: a nationwide population-based nested case-control study. J Bone Joint Surg Am 92: 1063-1072.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1063-1072
    • Thillemann, T.M.1    Pedersen, A.B.2    Mehnert, F.3
  • 15
    • 0004292914 scopus 로고    scopus 로고
    • 3rd ed. Philadelphia: Wolters Kluwer, Lippincott, Williams & Wilkins
    • Rothman KJ, Greenland S, Lash T., 2008. Modern epidemiology, 3rd ed. Philadelphia: Wolters Kluwer, Lippincott, Williams & Wilkins.
    • (2008) Modern Epidemiology
    • Rothman, K.J.1    Greenland, S.2    Lash, T.3
  • 17
    • 33744984130 scopus 로고    scopus 로고
    • The value of patient activity level in the outcome of total hip arthroplasty
    • Beaule PE, Dorey FJ, Hoke R, et al. 2006. The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty 21: 547-552.
    • (2006) J Arthroplasty , vol.21 , pp. 547-552
    • Beaule, P.E.1    Dorey, F.J.2    Hoke, R.3
  • 18
    • 62449228038 scopus 로고    scopus 로고
    • Which is the best activity rating scale for patients undergoing total joint arthroplasty
    • Naal FD, Impellizzeri FM, Leunig M., 2008. Which is the best activity rating scale for patients undergoing total joint arthroplasty ? Clin Orthop Relat Res 467: 958-965.
    • (2008) Clin Orthop Relat Res , vol.467 , pp. 958-965
    • Naal, F.D.1    Impellizzeri, F.M.2    Leunig, M.3
  • 19
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • Harris WH., 1969. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51: 737-755.
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 20
    • 0030096228 scopus 로고    scopus 로고
    • A 12-Item Short-Form Health Survey: Construction of scales and preliminary tests of reliability and validity
    • Ware J Jr, Kosinski M, Keller SD., 1996. A 12-Item Short-Form Health Survey: construction of scales and preliminary tests of reliability and validity. Med Care 34: 220-233.
    • (1996) Med Care , vol.34 , pp. 220-233
    • Ware, Jr.J.1    Kosinski, M.2    Keller, S.D.3
  • 21
    • 0033009808 scopus 로고    scopus 로고
    • Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study
    • Clohisy JC, Harris WH., 1999. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. J Bone Joint Surg Am 81: 247-255.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 247-255
    • Clohisy, J.C.1    Harris, W.H.2
  • 22
    • 0029557806 scopus 로고
    • Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study
    • Mulroy WF, Estok DM, Harris WH., 1995. Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. J Bone Joint Surg Am 77: 1845-1852.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1845-1852
    • Mulroy, W.F.1    Estok, D.M.2    Harris, W.H.3
  • 23
    • 0018687995 scopus 로고
    • Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC., 1979. " Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141: 17-27.
    • (1979) Clin Orthop Relat Res , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 24
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review
    • Barrack RL, Mulroy RD Jr, Harris WH., 1992. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 74: 385-389.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 385-389
    • Barrack, R.L.1    Mulroy, Jr.R.D.2    Harris, W.H.3
  • 25
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG., 1977. The measurement of observer agreement for categorical data. Biometrics 33: 159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 26
    • 0036713186 scopus 로고    scopus 로고
    • Interobserver and intraobserver variability in radiographic assessment of osteolysis
    • Engh CA Jr, Sychterz CJ, Young AM, et al. 2002. Interobserver and intraobserver variability in radiographic assessment of osteolysis. J Arthroplasty 17: 752-759.
    • (2002) J Arthroplasty , vol.17 , pp. 752-759
    • Engh, Jr.C.A.1    Sychterz, C.J.2    Young, A.M.3
  • 27
    • 0032856772 scopus 로고    scopus 로고
    • Management of osteolysis around total hip arthroplasty
    • Berry DJ., 1999. Management of osteolysis around total hip arthroplasty. Orthopedics 22: 805-808.
    • (1999) Orthopedics , vol.22 , pp. 805-808
    • Berry, D.J.1
  • 28
    • 33748946541 scopus 로고    scopus 로고
    • Effects of orthopaedic wear particles on osteoprogenitor cells
    • Goodman SB, Ma T, Chiu R, et al. 2006. Effects of orthopaedic wear particles on osteoprogenitor cells. Biomaterials 27: 6096-6101.
    • (2006) Biomaterials , vol.27 , pp. 6096-6101
    • Goodman, S.B.1    Ma, T.2    Chiu, R.3
  • 29
    • 0035985804 scopus 로고    scopus 로고
    • The role of statins as potential targets for bone formation
    • Garrett IR, Mundy GR., 2002. The role of statins as potential targets for bone formation. Arthritis Res 4: 237-240.
    • (2002) Arthritis Res , vol.4 , pp. 237-240
    • Garrett, I.R.1    Mundy, G.R.2
  • 30
    • 80053549892 scopus 로고    scopus 로고
    • The potential role of human osteoblasts for periprosthetic osteolysis
    • Lochner K, Fritsche A, Jonitz A, et al. 2011. The potential role of human osteoblasts for periprosthetic osteolysis. Int J Mol Med 28: 1055-1063.
    • (2011) Int J Mol Med , vol.28 , pp. 1055-1063
    • Lochner, K.1    Fritsche, A.2    Jonitz, A.3
  • 31
    • 34548335255 scopus 로고    scopus 로고
    • Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup
    • Berli BJ, Ping G, Dick W, et al. 2007. Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup. Clin Orthop Relat Res 461: 114-121.
    • (2007) Clin Orthop Relat Res , vol.461 , pp. 114-121
    • Berli, B.J.1    Ping, G.2    Dick, W.3
  • 32
    • 67650166165 scopus 로고    scopus 로고
    • The Morscher Press Fit acetabular component: A nine- to 13-year review
    • Gwynne-Jones DP, Garneti N, Wainwright C, et al. 2009. The Morscher Press Fit acetabular component: a nine- to 13-year review. J Bone Joint Surg Br 91: 859-864.
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 859-864
    • Gwynne-Jones, D.P.1    Garneti, N.2    Wainwright, C.3
  • 33
    • 79961167487 scopus 로고    scopus 로고
    • Ten-year results with the Morscher press-fit cup: An uncemented, non-modular, porous-coated cup inserted without screws
    • Garavaglia G, Lübbeke A, Barea C, et al. 2011. Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws. Int Orthop 35: 957-963.
    • (2011) Int Orthop , vol.35 , pp. 957-963
    • Garavaglia, G.1    Lübbeke, A.2    Barea, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.