메뉴 건너뛰기




Volumn 85, Issue 4, 2013, Pages 999-1005

Planning 4-dimensional computed tomography (4DCT) cannot adequately represent daily intrafractional motion of abdominal tumors

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTERIZED TOMOGRAPHY; IMAGE RESOLUTION; RADIOTHERAPY; TUMORS;

EID: 84875219505     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2012.09.014     Document Type: Article
Times cited : (116)

References (16)
  • 1
    • 69549113003 scopus 로고    scopus 로고
    • Residual motion and duty time in respiratory gating radiotherapy using individualized or population-based windows
    • H. Fuji, Y. Asada, and M. Numano Residual motion and duty time in respiratory gating radiotherapy using individualized or population-based windows Int J Radiat Oncol Biol Phys 75 2009 564 570
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 564-570
    • Fuji, H.1    Asada, Y.2    Numano, M.3
  • 2
    • 58149277214 scopus 로고    scopus 로고
    • Planning lung radiotherapy using 4D CT data and a motion model
    • R. Colgan, J. McClelland, and D. McQuaid Planning lung radiotherapy using 4D CT data and a motion model Phys Med Biol 53 2008 5815 5830
    • (2008) Phys Med Biol , vol.53 , pp. 5815-5830
    • Colgan, R.1    McClelland, J.2    McQuaid, D.3
  • 3
    • 67749122516 scopus 로고    scopus 로고
    • Impact of respiratory gating using 4-dimensional computed tomography on the dosimetry of tumor and normal tissues in patients with thoracic malignancies
    • M. Vlachaki, I. Castellon, and C. Leite Impact of respiratory gating using 4-dimensional computed tomography on the dosimetry of tumor and normal tissues in patients with thoracic malignancies Am J Clin Oncol 32 2009 262 268
    • (2009) Am J Clin Oncol , vol.32 , pp. 262-268
    • Vlachaki, M.1    Castellon, I.2    Leite, C.3
  • 4
    • 10744222972 scopus 로고    scopus 로고
    • A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
    • D.A. Low, M. Nystrom, and E. Kalinin A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing Med Phys 30 2003 1254 1263
    • (2003) Med Phys , vol.30 , pp. 1254-1263
    • Low, D.A.1    Nystrom, M.2    Kalinin, E.3
  • 5
    • 69349095126 scopus 로고    scopus 로고
    • Pancreatic tumor motion on a single planning 4D-CT does not correlate with intrafraction tumor motion during treatment
    • A.Y. Minn, D. Schellenberg, and P. Maxim Pancreatic tumor motion on a single planning 4D-CT does not correlate with intrafraction tumor motion during treatment Am J Clin Oncol 32 2009 364 368
    • (2009) Am J Clin Oncol , vol.32 , pp. 364-368
    • Minn, A.Y.1    Schellenberg, D.2    Maxim, P.3
  • 6
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • S.S. Korreman, T. Juhler-Nottrup, and A.L. Boyer Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance Radiother Oncol 86 2008 61 68
    • (2008) Radiother Oncol , vol.86 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3
  • 7
    • 78149476733 scopus 로고    scopus 로고
    • Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy
    • J. Cai, R. McLawhorn, and P.W. Read Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy Med Phys 37 2010 3927 3934
    • (2010) Med Phys , vol.37 , pp. 3927-3934
    • Cai, J.1    McLawhorn, R.2    Read, P.W.3
  • 8
    • 84857618595 scopus 로고    scopus 로고
    • Quantifying ITV instabilities arising from 4DCT: A simulation study using patient data
    • S.S. James, P. Mishra, and F. Hacker Quantifying ITV instabilities arising from 4DCT: A simulation study using patient data Phys Med Biol 57 2012 L1 L7
    • (2012) Phys Med Biol , vol.57
    • James, S.S.1    Mishra, P.2    Hacker, F.3
  • 9
    • 84857630945 scopus 로고    scopus 로고
    • Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements
    • A.J. Cherpak, J.E. Cygler, and S. Andrusyk Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements Radiother Oncol 102 2012 290 296
    • (2012) Radiother Oncol , vol.102 , pp. 290-296
    • Cherpak, A.J.1    Cygler, J.E.2    Andrusyk, S.3
  • 10
    • 33645972885 scopus 로고    scopus 로고
    • Changes in the respiratory pattern during radiotherapy for cancer in the lung
    • G. Hugo, C. Vargas, and J. Liang Changes in the respiratory pattern during radiotherapy for cancer in the lung Radiother Oncol 78 2006 326 331
    • (2006) Radiother Oncol , vol.78 , pp. 326-331
    • Hugo, G.1    Vargas, C.2    Liang, J.3
  • 11
    • 41749103352 scopus 로고    scopus 로고
    • Organ deformation and dose coverage in robotic respiratory-tracking radiotherapy
    • X.Q. Lu, L.N. Shanmugham, and A. Mahadevan Organ deformation and dose coverage in robotic respiratory-tracking radiotherapy Int J Radiat Oncol Biol Phys 71 2008 281 289
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 281-289
    • Lu, X.Q.1    Shanmugham, L.N.2    Mahadevan, A.3
  • 12
    • 84862660475 scopus 로고    scopus 로고
    • Accumulated dose in liver stereotactic body radiotherapy: Positioning, breathing, and deformation effects
    • M. Velec, J.L. Moseley, and T. Craig Accumulated dose in liver stereotactic body radiotherapy: Positioning, breathing, and deformation effects Int J Radiat Oncol Biol Phys 83 2012 1132 1140
    • (2012) Int J Radiat Oncol Biol Phys , vol.83 , pp. 1132-1140
    • Velec, M.1    Moseley, J.L.2    Craig, T.3
  • 13
    • 84865583720 scopus 로고    scopus 로고
    • Video-coaching as biofeedback tool to improve gated treatments: Possibilities and limitations
    • P.H. Cossmann Video-coaching as biofeedback tool to improve gated treatments: Possibilities and limitations Z Med Phys 22 2012 224 230
    • (2012) Z Med Phys , vol.22 , pp. 224-230
    • Cossmann, P.H.1
  • 14
    • 33646927016 scopus 로고    scopus 로고
    • Audio-visual biofeedback for respiratory-gated radiotherapy: Impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy
    • R. George, T.D. Chung, and S.S. Vedam Audio-visual biofeedback for respiratory-gated radiotherapy: Impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy Int J Radiat Oncol Biol Phys 65 2006 924 933
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 924-933
    • George, R.1    Chung, T.D.2    Vedam, S.S.3
  • 16
    • 51049088186 scopus 로고    scopus 로고
    • Can audio coached 4D CT emulate free breathing during the treatment course?
    • G.F. Persson, D.E. Nygaard, and M. Olsen Can audio coached 4D CT emulate free breathing during the treatment course? Acta Oncol 47 2008 1397 1405
    • (2008) Acta Oncol , vol.47 , pp. 1397-1405
    • Persson, G.F.1    Nygaard, D.E.2    Olsen, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.