메뉴 건너뛰기




Volumn 20, Issue 4, 2013, Pages 430-439

The Utility of Micro-CT and MRI in the Assessment of Longitudinal Growth of Liver Metastases in a Preclinical Model of Colon Carcinoma

Author keywords

CT; Liver metastases; Mice; MR; PROPELLER

Indexed keywords

IOPAMIDOL;

EID: 84875078605     PISSN: 10766332     EISSN: 18784046     Source Type: Journal    
DOI: 10.1016/j.acra.2012.09.030     Document Type: Article
Times cited : (24)

References (20)
  • 2
    • 0033065833 scopus 로고    scopus 로고
    • Positron emission tomography of murine liver metastases and the effects of treatment by combretastatin A-4
    • Zhao S., Moore J.V., Waller M.L., et al. Positron emission tomography of murine liver metastases and the effects of treatment by combretastatin A-4. Eur J Nucl Med 1999, 26:231-238.
    • (1999) Eur J Nucl Med , vol.26 , pp. 231-238
    • Zhao, S.1    Moore, J.V.2    Waller, M.L.3
  • 3
    • 33847066329 scopus 로고    scopus 로고
    • Monitoring of disease progression by bioluminescence imaging and magnetic resonance imaging in an animal model of hematologic malignancy
    • Inoue Y., Izawa K., Tojo A., et al. Monitoring of disease progression by bioluminescence imaging and magnetic resonance imaging in an animal model of hematologic malignancy. Exp Hematol 2007, 35:407-415.
    • (2007) Exp Hematol , vol.35 , pp. 407-415
    • Inoue, Y.1    Izawa, K.2    Tojo, A.3
  • 4
    • 8844225001 scopus 로고    scopus 로고
    • Validation of bioluminescence imaging of colorectal liver metastases in the mouse
    • Smakman N., Martens A., Kranenburg O., et al. Validation of bioluminescence imaging of colorectal liver metastases in the mouse. J Surg Res 2004, 122:225-230.
    • (2004) J Surg Res , vol.122 , pp. 225-230
    • Smakman, N.1    Martens, A.2    Kranenburg, O.3
  • 5
    • 72149091979 scopus 로고    scopus 로고
    • In vivo micro-CT imaging of liver lesions in small animal models
    • Martiniova L., Schimel D., Lai E.W., et al. In vivo micro-CT imaging of liver lesions in small animal models. Methods 2009, 50:20-25.
    • (2009) Methods , vol.50 , pp. 20-25
    • Martiniova, L.1    Schimel, D.2    Lai, E.W.3
  • 6
    • 77349085317 scopus 로고    scopus 로고
    • Magnetic resonance imaging follow-up of liver growth of neuroendocrine tumors in an experimental mouse model
    • Baboi L., Pilleul F., Milot L., et al. Magnetic resonance imaging follow-up of liver growth of neuroendocrine tumors in an experimental mouse model. Magn Reson Imaging 2009, 28:264-272.
    • (2009) Magn Reson Imaging , vol.28 , pp. 264-272
    • Baboi, L.1    Pilleul, F.2    Milot, L.3
  • 7
    • 24644459789 scopus 로고    scopus 로고
    • A mouse model for developing treatment for secondary liver tumors
    • Cai S.R., Garbow J.R., Culverhouse R., et al. A mouse model for developing treatment for secondary liver tumors. Int J Oncol 2005, 27:113-120.
    • (2005) Int J Oncol , vol.27 , pp. 113-120
    • Cai, S.R.1    Garbow, J.R.2    Culverhouse, R.3
  • 8
    • 57049149085 scopus 로고    scopus 로고
    • Longitudinal in vivo susceptibility contrast MRI measurements of LS174T colorectal liver metastasis in nude mice
    • Kalber T.L., Waterton J.C., Griffiths J.R., et al. Longitudinal in vivo susceptibility contrast MRI measurements of LS174T colorectal liver metastasis in nude mice. J Magn Reson Imaging 2008, 28:1451-1458.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1451-1458
    • Kalber, T.L.1    Waterton, J.C.2    Griffiths, J.R.3
  • 9
    • 11244304503 scopus 로고    scopus 로고
    • Micro-CT with respiratory and cardiac gating
    • Badea C.T., Hedlund L.W., Johnson G.A. Micro-CT with respiratory and cardiac gating. Med Phys 2004, 31:3324-3329.
    • (2004) Med Phys , vol.31 , pp. 3324-3329
    • Badea, C.T.1    Hedlund, L.W.2    Johnson, G.A.3
  • 10
    • 77953952860 scopus 로고    scopus 로고
    • Multi-shot PROPELLER for high-field MRI
    • Pandit P., Qi Y., Story J., et al. Multi-shot PROPELLER for high-field MRI. Magn Reson Med 2010, 64:47-53.
    • (2010) Magn Reson Med , vol.64 , pp. 47-53
    • Pandit, P.1    Qi, Y.2    Story, J.3
  • 11
    • 79251552556 scopus 로고    scopus 로고
    • Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging
    • Pandit P., Qi Y., King K.F., et al. Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging. Magn Reson Med 2011, 65:538-543.
    • (2011) Magn Reson Med , vol.65 , pp. 538-543
    • Pandit, P.1    Qi, Y.2    King, K.F.3
  • 12
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging
    • Pipe J.G. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999, 42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 13
    • 26944469103 scopus 로고    scopus 로고
    • 4D micro-CT of the mouse heart
    • Badea C., Fubara B., Hedlund L., et al. 4D micro-CT of the mouse heart. Mol Imaging 2005, 4:110-116.
    • (2005) Mol Imaging , vol.4 , pp. 110-116
    • Badea, C.1    Fubara, B.2    Hedlund, L.3
  • 14
    • 33644981609 scopus 로고    scopus 로고
    • A liposomal nanoscale contrast agent for preclincal CT in mice
    • Mukundan S., Ghaghada K.B., Badea C.T., et al. A liposomal nanoscale contrast agent for preclincal CT in mice. AJR Am J Roentgenol 2006, 186:300-307.
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 300-307
    • Mukundan, S.1    Ghaghada, K.B.2    Badea, C.T.3
  • 15
    • 0028868358 scopus 로고
    • Effects of iodinated contrast agents in MR imaging
    • Hergan K., Doringer W., Langle M., et al. Effects of iodinated contrast agents in MR imaging. Eur J Radiol 1995, 21:11-17.
    • (1995) Eur J Radiol , vol.21 , pp. 11-17
    • Hergan, K.1    Doringer, W.2    Langle, M.3
  • 16
    • 68049139719 scopus 로고    scopus 로고
    • Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabrication
    • Howles G.P., Nouls J.C., Qi Y., et al. Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabrication. J Magn Reson Imaging 2009, 30:466-471.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 466-471
    • Howles, G.P.1    Nouls, J.C.2    Qi, Y.3
  • 17
    • 49249094515 scopus 로고    scopus 로고
    • Application of MOSFET detectors in small animal digital subtraction angiography (DSA) dosimetry
    • Lin M., Toncheva G., Nguyen G., et al. Application of MOSFET detectors in small animal digital subtraction angiography (DSA) dosimetry. Radiat Res 2008, 170:260-263.
    • (2008) Radiat Res , vol.170 , pp. 260-263
    • Lin, M.1    Toncheva, G.2    Nguyen, G.3
  • 18
    • 0026645150 scopus 로고
    • The accuracy of signal intensity measurements in magnetic resonance imaging as evaluated with the knee
    • Berns G.S., Howell S.M., Farley T.E. The accuracy of signal intensity measurements in magnetic resonance imaging as evaluated with the knee. Mag Reson Imaging 1992, 10:573-578.
    • (1992) Mag Reson Imaging , vol.10 , pp. 573-578
    • Berns, G.S.1    Howell, S.M.2    Farley, T.E.3
  • 19
    • 0345688224 scopus 로고    scopus 로고
    • Fundamental image quality limits for microcomputed tomography in small animals
    • Ford N.L., Thornton M.M., Holdsworth D.W. Fundamental image quality limits for microcomputed tomography in small animals. Med Phys 2003, 30:2869-2877.
    • (2003) Med Phys , vol.30 , pp. 2869-2877
    • Ford, N.L.1    Thornton, M.M.2    Holdsworth, D.W.3
  • 20
    • 63449128201 scopus 로고    scopus 로고
    • Noninvasive monitoring of a murine model of metastatic pheochromocytoma: a comparison of contrast-enhanced microCT and nonenhanced MRI
    • Martiniova L., Kotys M.S., Thomasson D., et al. Noninvasive monitoring of a murine model of metastatic pheochromocytoma: a comparison of contrast-enhanced microCT and nonenhanced MRI. J Magn Reson Imaging 2009, 29:685-691.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 685-691
    • Martiniova, L.1    Kotys, M.S.2    Thomasson, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.