메뉴 건너뛰기




Volumn 84, Issue 2, 2013, Pages

A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG ELECTRONIC CIRCUIT; DISCRIMINATION THRESHOLDS; LIGHT SPOT POSITION; MEASUREMENT RANGE; MEASURING SYSTEMS; POSITION-SENSITIVE DETECTORS; STATIC CALIBRATION; WORKING PRINCIPLES;

EID: 84874912220     PISSN: 00346748     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.4793227     Document Type: Conference Paper
Times cited : (29)

References (14)
  • 1
    • 84866525335 scopus 로고    scopus 로고
    • Optical-fiber measurement systems for medical applications
    • edited by P. Predee(InTech)
    • S. Silvestri and E. Schena, " Optical-fiber measurement systems for medical applications.," in Optoelectronics-Devices and Applications, edited by, P. Predeep, (InTech, 2011), pp. 205-224.
    • (2011) Optoelectronics - Devices and Applications , pp. 205-224
    • Silvestri, S.1    Schena, E.2
  • 2
    • 0003419052 scopus 로고    scopus 로고
    • Wiley, Hoboken, New Jersey
    • E. Udd, Fiber Optic Sensors (Wiley, Hoboken, New Jersey, 2006).
    • (2006) Fiber Optic Sensors
    • Udd, E.1
  • 3
    • 79951548048 scopus 로고    scopus 로고
    • A simple fiber-optic flowmeter based on bending loss
    • 10.1109/JSEN.2009.2031845
    • R. P. Hu and X. G. Huang, " A simple fiber-optic flowmeter based on bending loss.," IEEE Sens. J. 9 (12), 1052-1955 (2009). 10.1109/JSEN.2009.2031845
    • (2009) IEEE Sens. J. , vol.9 , Issue.12 , pp. 1052-1955
    • Hu, R.P.1    Huang, X.G.2
  • 4
    • 49749117963 scopus 로고    scopus 로고
    • Optical fiber-based macrobend free air flow sensor using a hinge joint: A preliminary report
    • 10.1002/mo23746
    • A. Vijayan, V. Thakare, R. N. Karekar, and R. C. Aiyer " Optical fiber-based macrobend free air flow sensor using a hinge joint: A preliminary report.," Microwave Opt. Technol. Lett. 50 (10), 2543-2546 (2008). 10.1002/mop.23746
    • (2008) Microwave Opt. Technol. Lett. , vol.50 , Issue.10 , pp. 2543-2546
    • Vijayan, A.1    Thakare, V.2    Karekar, R.N.3    Aiyer, R.C.4
  • 5
    • 0035426146 scopus 로고    scopus 로고
    • DP flow sensor using optical fibre Bragg grating
    • 10.1016/S0924-4247(01)00546-5
    • J. Lim, Q. P. Yang, B. E. Jones, and P. R. Jackson, " DP flow sensor using optical fibre Bragg grating.," Sens. Actuators A 92 (1-3), 102-108 (2001). 10.1016/S0924-4247(01)00546-5
    • (2001) Sens. Actuators A , vol.92 , Issue.13 , pp. 102-108
    • Lim, J.1    Yang, Q.P.2    Jones, B.E.3    Jackson, P.R.4
  • 6
    • 27144541804 scopus 로고    scopus 로고
    • Novel target flowmeter based on differential fiber Bragg grating sensor
    • 10.1016/j.measurement.2005.07.005
    • Y. Zhao, K. Chen, and J. Yang, " Novel target flowmeter based on differential fiber Bragg grating sensor.," Measurement 38, 230-235 (2005). 10.1016/j.measurement.2005.07.005
    • (2005) Measurement , vol.38 , pp. 230-235
    • Zhao, Y.1    Chen, K.2    Yang, J.3
  • 7
    • 64549143327 scopus 로고    scopus 로고
    • Fiber Bragg grating sensor for simultaneous measurement of flow rate and direction
    • 10.1088/0957-0233/19/12/125302
    • P. Lu and Q. Chen, " Fiber Bragg grating sensor for simultaneous measurement of flow rate and direction.," Meas. Sci. Technol. 19 (12), 125302 (2008). 10.1088/0957-0233/19/12/125302
    • (2008) Meas. Sci. Technol. , vol.19 , Issue.12 , pp. 125302
    • Lu, P.1    Chen, Q.2
  • 8
    • 70350183734 scopus 로고    scopus 로고
    • A cantilever force sensor combined with a spherical reflecting mirror for sensitivity enhancement of an optical detection system
    • 10.1109/JSTQE.2009.2019615
    • C. Liao and J. Tsai, " A cantilever force sensor combined with a spherical reflecting mirror for sensitivity enhancement of an optical detection system.," IEEE J. Select. Top. Quant. Electron. 15 (5), 1463-1468 (2009). 10.1109/JSTQE.2009.2019615
    • (2009) IEEE J. Select. Top. Quant. Electron. , vol.15 , Issue.5 , pp. 1463-1468
    • Liao, C.1    Tsai, J.2
  • 9
    • 79952166554 scopus 로고    scopus 로고
    • A novel target type low pressure-drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: Measurement principle and static calibration
    • 10.1063/1.3549624
    • P. Saccomandi, E. Schena, and S. Silvestri, " A novel target type low pressure-drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: Measurement principle and static calibration.," Rev. Sci. Instrum. 82 (2), 024301 (2011). 10.1063/1.3549624
    • (2011) Rev. Sci. Instrum. , vol.82 , Issue.2 , pp. 024301
    • Saccomandi, P.1    Schena, E.2    Silvestri, S.3
  • 12
  • 14
    • 67650890638 scopus 로고    scopus 로고
    • Evaluation of measurement data - Guide to the expression of uncertainty in measurement
    • Evaluation of measurement data-Guide to the expression of uncertainty in measurement, JCGM 100, 2008.
    • (2008) JCGM , vol.100


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.