-
1
-
-
26444453569
-
Two-hole side-plate DHS in the treatment of intertrochanteric fracture: Results and complications
-
DOI 10.1016/j.injury.2005.04.014, PII S0020138305001464
-
Laohapoonrungsee A., Arpornchayanon O., Phornputkul C., Two-hole side-plate DHS in the treatment of intertrochanteric fracture: results and complications. Injury 2005 36 11 1355 1360 2-s2.0-26444453569 10.1016/j.injury.2005.04.014 (Pubitemid 41427217)
-
(2005)
Injury
, vol.36
, Issue.11
, pp. 1355-1360
-
-
Laohapoonrungsee, A.1
Arpornchayanon, O.2
Phornputkul, C.3
-
2
-
-
0026090325
-
Fixation of intertrochanteric fractures of the femur. A randomized prospective comparison of the Gamma nail and the dynamic hip screw
-
2-s2.0-0026090325
-
Bridle S. H., Patel A. D., Bircher M., Calvert P. T., Fixation of intertrochanteric fractures of the femur. A randomized prospective comparison of the Gamma nail and the dynamic hip screw. Journal of Bone and Joint Surgery B 1991 73 2 330 334 2-s2.0-0026090325
-
(1991)
Journal of Bone and Joint Surgery B
, vol.73
, Issue.2
, pp. 330-334
-
-
Bridle, S.H.1
Patel, A.D.2
Bircher, M.3
Calvert, P.T.4
-
3
-
-
0027170493
-
A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
-
Radford P. J., Needoff M., Webb J. K., A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. Journal of Bone and Joint Surgery B 1993 75 5 789 793 2-s2.0-0027170493 (Pubitemid 23267948)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.5
, pp. 789-793
-
-
Radford, P.J.1
Needoff, M.2
Webb, J.K.3
-
4
-
-
33847656750
-
Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation
-
DOI 10.2106/JBJS.F.00679
-
Palm H., Jacobsen S., Sonne-Holm S., Gebuhr P., Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. Journal of Bone and Joint Surgery A 2007 89 3 470 475 2-s2.0-33847656750 10.2106/JBJS.F.00679 (Pubitemid 46365346)
-
(2007)
Journal of Bone and Joint Surgery - Series A
, vol.89
, Issue.3
, pp. 470-475
-
-
Palm, H.1
Jacobsen, S.2
Sonne-Holm, S.3
Gebuhr, P.4
-
5
-
-
35848964606
-
A prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip
-
DOI 10.1302/0301-620X.89B9.18824
-
Peyser A., Weil Y. A., Brocke L., Sela Y., Mosheiff R., Mattan Y., Manor O., Liebergall M., A prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip. Journal of Bone and Joint Surgery B 2007 89 9 1210 1217 2-s2.0-35848964606 10.1302/0301-620X.89B9.18824 (Pubitemid 350057959)
-
(2007)
Journal of Bone and Joint Surgery - Series B
, vol.89
, Issue.9
, pp. 1210-1217
-
-
Peyser, A.1
Weil, Y.A.2
Brocke, L.3
Sela, Y.4
Mosheiff, R.5
Mattan, Y.6
Manor, O.7
Liebergall, M.8
-
6
-
-
17144467492
-
Reverse obliquity fractures of the intertrochanteric region of the femur
-
2-s2.0-17144467492
-
Haidukewych G. J., Israel T. A., Berry D. J., Reverse obliquity fractures of the intertrochanteric region of the femur. Journal of Bone and Joint Surgery A 2001 83 5 643 650 2-s2.0-17144467492
-
(2001)
Journal of Bone and Joint Surgery A
, vol.83
, Issue.5
, pp. 643-650
-
-
Haidukewych, G.J.1
Israel, T.A.2
Berry, D.J.3
-
7
-
-
78549289900
-
Risk factors in cutout of sliding hip screw in intertrochanteric fractures: An evaluation of 937 patients
-
2-s2.0-78549289900 10.1007/s00264-009-0866-2
-
Hsueh K. K., Fang C. K., Chen C. M., Su Y. P., Wu H. F., Chiu F. Y., Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. International Orthopaedics 2010 34 8 1273 1276 2-s2.0-78549289900 10.1007/s00264-009-0866-2
-
(2010)
International Orthopaedics
, vol.34
, Issue.8
, pp. 1273-1276
-
-
Hsueh, K.K.1
Fang, C.K.2
Chen, C.M.3
Su, Y.P.4
Wu, H.F.5
Chiu, F.Y.6
-
9
-
-
19544380612
-
Sliding hip screw fixation of trochanteric hip fractures: Outcome of 1024 procedures
-
DOI 10.1016/j.injury.2005.01.017, PII S0020138305000380
-
Chirodian N., Arch B., Parker M. J., Sliding hip screw fixation of trochanteric hip fractures: outcome of 1024 procedures. Injury 2005 36 6 793 800 2-s2.0-19544380612 10.1016/j.injury.2005.01.017 (Pubitemid 40732319)
-
(2005)
Injury
, vol.36
, Issue.6
, pp. 793-800
-
-
Chirodian, N.1
Arch, B.2
Parker, M.J.3
-
10
-
-
0026764040
-
Cutting-out of the dynamic hip screw related to its position
-
2-s2.0-0026764040
-
Parker M. J., Cutting-out of the dynamic hip screw related to its position. Journal of Bone and Joint Surgery B 1992 74 4 625 2-s2.0-0026764040
-
(1992)
Journal of Bone and Joint Surgery B
, vol.74
, Issue.4
, pp. 625
-
-
Parker, M.J.1
-
11
-
-
0025034792
-
Intertrochanteric femoral fractures. Mechanical failure after internal fixation
-
Davis T. R. C., Sher J. L., Horsman A., Simpson M., Porter B. B., Checketts R. G., Intertrochanteric femoral fractures. Mechanical failure after internal fixation. Journal of Bone and Joint Surgery B 1990 72 1 26 31 2-s2.0-0025034792 (Pubitemid 20035810)
-
(1990)
Journal of Bone and Joint Surgery - Series B
, vol.72
, Issue.1
, pp. 26-31
-
-
Davis, T.R.C.1
Sher, J.L.2
Horsman, A.3
Simpson, M.4
Porter, B.B.5
Checketts, R.G.6
-
12
-
-
0024580353
-
Implant failures in a patients with proximal fractures of the femur treated with a sliding screw device
-
DOI 10.1016/0020-1383(89)90151-4
-
Mainds C. C., Newman R. J., Implant failures in a patients with proximal fractures of the femur treated with a sliding screw device. Injury 1989 20 2 98 100 2-s2.0-0024580353 (Pubitemid 19095523)
-
(1989)
Injury
, vol.20
, Issue.2
, pp. 98-100
-
-
Mainds, C.C.1
Newman, R.J.2
-
13
-
-
0026071143
-
Dynamic hip screws that fail
-
2-s2.0-0026071143 10.1016/0020-1383(91)90161-7
-
Thomas A. P., Dynamic hip screws that fail. Injury 1991 22 1 45 46 2-s2.0-0026071143 10.1016/0020-1383(91)90161-7
-
(1991)
Injury
, vol.22
, Issue.1
, pp. 45-46
-
-
Thomas, A.P.1
-
14
-
-
0029012764
-
The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
-
2-s2.0-0029012764
-
Baumgaertner M. R., Curtin S. L., Lindskog D. M., Keggi J. M., The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. Journal of Bone and Joint Surgery A 1995 77 7 1058 1064 2-s2.0-0029012764
-
(1995)
Journal of Bone and Joint Surgery A
, vol.77
, Issue.7
, pp. 1058-1064
-
-
Baumgaertner, M.R.1
Curtin, S.L.2
Lindskog, D.M.3
Keggi, J.M.4
-
15
-
-
0030720275
-
Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
-
Baumgaertner M. R., Solberg B. D., Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. Journal of Bone and Joint Surgery B 1997 79 6 969 971 2-s2.0-0030720275 (Pubitemid 27499589)
-
(1997)
Journal of Bone and Joint Surgery - Series B
, vol.79
, Issue.6
, pp. 969-971
-
-
Baumgaertner, M.R.1
Solberg, B.D.2
-
16
-
-
62549096380
-
Intertrochanteric fractures: Ten tips to improve results
-
2-s2.0-62549096380
-
Haidukewych G. J., Intertrochanteric fractures: ten tips to improve results. Journal of Bone and Joint Surgery A 2009 91 3 712 719 2-s2.0-62549096380
-
(2009)
Journal of Bone and Joint Surgery A
, vol.91
, Issue.3
, pp. 712-719
-
-
Haidukewych, G.J.1
-
17
-
-
84876551252
-
Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures
-
10.1007/s00264-012-1636-0
-
Andruszkow H., Frink M., Fromke C., Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures. International Orthopaedics 2012 36 11 2347 2354 10.1007/s00264-012-1636-0
-
(2012)
International Orthopaedics
, vol.36
, Issue.11
, pp. 2347-2354
-
-
Andruszkow, H.1
Frink, M.2
Fromke, C.3
-
18
-
-
34249943149
-
Anterior or posterior obliquity of the lag screw in the lateral view-Does it affect the sliding characteristics on unstable trochanteric fractures?
-
DOI 10.1016/j.injury.2007.03.010, PII S0020138307001210
-
Park S. Y., Park J., Rhee D. J., Yoon H. K., Yang K. H., Anterior or posterior obliquity of the lag screw in the lateral view-Does it affect the sliding characteristics on unstable trochanteric fractures? Injury 2007 38 7 785 791 2-s2.0-34249943149 10.1016/j.injury.2007.03.010 (Pubitemid 46879748)
-
(2007)
Injury
, vol.38
, Issue.7
, pp. 785-791
-
-
Park, S.Y.1
Park, J.2
Rhee, D.J.3
Yoon, H.K.4
Yang, K.H.5
-
19
-
-
0025944925
-
Treatment of the unstable intertrochanteric fracture: Effect of the placement of the screw, its angle of insertion, and osteotomy
-
2-s2.0-0025944925
-
Den Hartog B. D., Bartal E., Cooke F., Treatment of the unstable intertrochanteric fracture: effect of the placement of the screw, its angle of insertion, and osteotomy. Journal of Bone and Joint Surgery A 1991 73 5 726 733 2-s2.0-0025944925
-
(1991)
Journal of Bone and Joint Surgery A
, vol.73
, Issue.5
, pp. 726-733
-
-
Den Hartog, B.D.1
Bartal, E.2
Cooke, F.3
-
20
-
-
0026842367
-
Treatment of the unstable intertrochanteric fracture. Effect of the placement of the screw, its angle of insertion, and osteotomy
-
2-s2.0-0026842367
-
Fleiss D. J., Treatment of the unstable intertrochanteric fracture. Effect of the placement of the screw, its angle of insertion, and osteotomy. Journal of Bone and Joint Surgery A 1992 74 4 633 2-s2.0-0026842367
-
(1992)
Journal of Bone and Joint Surgery A
, vol.74
, Issue.4
, pp. 633
-
-
Fleiss, D.J.1
-
21
-
-
44949212693
-
Anterior or posterior obliquity of the lag screw in the lateral view-Does it affect the sliding characteristics on unstable trochanteric fractures?
-
2-s2.0-44949212693 10.1016/j.injury.2008.02.020
-
Mereddy P. K. R., Sunderamoorthy D., Anterior or posterior obliquity of the lag screw in the lateral view-Does it affect the sliding characteristics on unstable trochanteric fractures? Injury 2008 39 7 822 2-s2.0-44949212693 10.1016/j.injury.2008.02.020
-
(2008)
Injury
, vol.39
, Issue.7
, pp. 822
-
-
Mereddy, P.K.R.1
Sunderamoorthy, D.2
-
22
-
-
57349085028
-
Is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? A biomechanical investigation
-
2-s2.0-57349085028 10.1016/j.clinbiomech.2008.07.004
-
Windolf M., Braunstein V., Dutoit C., Schwieger K., Is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? A biomechanical investigation. Clinical Biomechanics 2009 24 1 59 64 2-s2.0-57349085028 10.1016/j.clinbiomech.2008.07.004
-
(2009)
Clinical Biomechanics
, vol.24
, Issue.1
, pp. 59-64
-
-
Windolf, M.1
Braunstein, V.2
Dutoit, C.3
Schwieger, K.4
-
23
-
-
57349178352
-
Quantification of cancellous bone-compaction due to DHS® Blade insertion and influence upon cut-out resistance
-
2-s2.0-57349178352 10.1016/j.clinbiomech.2008.09.005
-
Windolf M., Muths R., Braunstein V., Gueorguiev B., Hänni M., Schwieger K., Quantification of cancellous bone-compaction due to DHS® Blade insertion and influence upon cut-out resistance. Clinical Biomechanics 2009 24 1 53 58 2-s2.0-57349178352 10.1016/j.clinbiomech.2008.09.005
-
(2009)
Clinical Biomechanics
, vol.24
, Issue.1
, pp. 53-58
-
-
Windolf, M.1
Muths, R.2
Braunstein, V.3
Gueorguiev, B.4
Hänni, M.5
Schwieger, K.6
-
24
-
-
79955124195
-
Dynamic hip screw versus DHS blade: A biomechanical comparison of the fixation achieved by each implant in bone
-
2-s2.0-79955124195 10.1302/0301-620X.93B5.25539
-
O'Neill F., Condon F., McGloughlin T., Lenehan B., Coffey J. C., Walsh M., Dynamic hip screw versus DHS blade: a biomechanical comparison of the fixation achieved by each implant in bone. Journal of Bone and Joint Surgery B 2011 93 5 616 621 2-s2.0-79955124195 10.1302/0301-620X.93B5.25539
-
(2011)
Journal of Bone and Joint Surgery B
, vol.93
, Issue.5
, pp. 616-621
-
-
O'Neill, F.1
Condon, F.2
McGloughlin, T.3
Lenehan, B.4
Coffey, J.C.5
Walsh, M.6
-
25
-
-
84874830738
-
Dynamic hip screw blade fixation for intertrochanteric hip fractures
-
Leung F., Gudushauri P., Yuen G., Dynamic hip screw blade fixation for intertrochanteric hip fractures. The Journal of Orthopaedic Surgery 2012 20 3 302 306
-
(2012)
The Journal of Orthopaedic Surgery
, vol.20
, Issue.3
, pp. 302-306
-
-
Leung, F.1
Gudushauri, P.2
Yuen, G.3
|