메뉴 건너뛰기




Volumn 122, Issue 3, 2013, Pages 183-189

Rigid bronchoscopic management of complications related to endobronchial stents after lung transplantation

Author keywords

Endobronchial stent; Lung transplant; Rigid bronchoscopy

Indexed keywords

CYCLOSPORIN; MYCOPHENOLIC ACID 2 MORPHOLINOETHYL ESTER; PREDNISONE; RAPAMYCIN; TACROLIMUS;

EID: 84874835735     PISSN: 00034894     EISSN: None     Source Type: Journal    
DOI: 10.1177/000348941312200307     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 0014803002 scopus 로고
    • A review of 23 human lung transplantations by 20 surgeons
    • Wildevuur CR, Benfield Jr. A review of 23 human lung transplantations by 20 surgeons. Ann Thorac Surg 1970;9:489-515.
    • (1970) Ann Thorac Surg , vol.9 , pp. 489-515
    • Wildevuur, C.R.1    Benfield, J.R.2
  • 2
    • 57949108698 scopus 로고    scopus 로고
    • Airway stenoses after lung transplantation: Incidence, management, and outcome
    • Thistlethwaite PA, Yung G, Kemp A, et al. Airway stenoses after lung transplantation: Incidence, management, and outcome. J Thorac Cardiovasc Surg 2008;136:1569-75.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1569-1575
    • Thistlethwaite, P.A.1    Yung, G.2    Kemp, A.3
  • 4
    • 0026344190 scopus 로고
    • Significance of bronchial mucosal blood flow for the monitoring of acute rejection in lung transplantation
    • Takao M, Katayama Y, Onoda K, et al. Significance of bronchial mucosal blood flow for the monitoring of acute rejection in lung transplantation. J Heart Lung Transplant 1991;10: 956-67.
    • (1991) J Heart Lung Transplant , vol.10 , pp. 956-967
    • Takao, M.1    Katayama, Y.2    Onoda, K.3
  • 6
    • 34447565906 scopus 로고    scopus 로고
    • Impact of anastomotic airway complications after lung transplantation
    • Members Of Cleveland Clinic's Pulmonary Transplant Team., 409.el-4
    • Murthy SC, Blackstone EH, Gildea TR, et al Members of Cleveland Clinic's Pulmonary Transplant Team. Impact of anastomotic airway complications after lung transplantation. Ann Thoracic Surg 2007;84:401-9, 409.el-4.
    • (2007) Ann Thoracic Surg , vol.84 , pp. 401-409
    • Murthy, S.C.1    Blackstone, E.H.2    Gildea, T.R.3
  • 7
    • 0038586440 scopus 로고    scopus 로고
    • The role of selfexpandable metallic stents for the treatment of airway complications after lung transplantation
    • Saad CP, Ghamande SA, Minai OA, et al. The role of selfexpandable metallic stents for the treatment of airway complications after lung transplantation. Transplantation 2003;75:1532-8.
    • (2003) Transplantation , vol.75 , pp. 1532-1538
    • Saad, C.P.1    Ghamande, S.A.2    Minai, O.A.3
  • 10
    • 77956470484 scopus 로고    scopus 로고
    • Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy
    • Fruchter O, Raviv Y, Fox BD, Kramer MR. Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy. J Cardiothorac Surg 2010;5:72.
    • (2010) J Cardiothorac Surg , vol.5 , pp. 72
    • Fruchter, O.1    Raviv, Y.2    Fox, B.D.3    Kramer, M.R.4
  • 11
    • 84874870999 scopus 로고    scopus 로고
    • FDA Public Health Notification: Complications From Metallic Tracheal Stents In Patients With Benign Airway Disorders. US Food And Drug Administration July 29, 2005. Accessed June 25 2012
    • FDA Public health notification: Complications from metallic tracheal stents in patients with benign airway disorders. US Food and Drug Administration, July 29, 2005. http://www.fda. gov/MedicalDevices/Safety/ AlertsandNotices/PublicHealth-Notifications/ucm062115.htm. Accessed June 25, 2012.
  • 12
    • 3042772569 scopus 로고    scopus 로고
    • Efficacy and safety of a retrieval hook for removal of retrievable expandable tracheobronchial stents
    • Kim JH, Shin JH, Shim TS, et al. Efficacy and safety of a retrieval hook for removal of retrievable expandable tracheobronchial stents. J Vasc Interv Radiol 2004;15:697-705.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 697-705
    • Kim, J.H.1    Shin, J.H.2    Shim, T.S.3
  • 13
    • 77952553670 scopus 로고    scopus 로고
    • A retrospective study of silicone stent placement for management of anastomotic airway complications in lung transplant recipients: Short-and long-term outcomes
    • Dutau H, Cavailles A, Sakr L, et al. A retrospective study of silicone stent placement for management of anastomotic airway complications in lung transplant recipients: Short-and long-term outcomes. J Heart Lung Transplant 2010;29:658-64.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 658-664
    • Dutau, H.1    Cavailles, A.2    Sakr, L.3
  • 14
    • 84857314625 scopus 로고    scopus 로고
    • Airway complications after lung transplantation: Long-term outcome of silicone stenting
    • Sundset A, Lund MB, Hansen G, Bjørtuft Ø, Kongerud J, Geiran OR. Airway complications after lung transplantation: Long-term outcome of silicone stenting. Respiration 2012;83: 245-52.
    • (2012) Respiration , vol.83 , pp. 245-252
    • Sundset, A.1    Lund, M.B.2    Hansen, G.3    Bjørtuft, Ø.4    Kongerud, J.5    Geiran, O.R.6
  • 15
    • 0026275479 scopus 로고
    • Gianturco self-expanding metallic stents in treatment of tracheobronchial stenosis after single lung and heart and lung transplantation
    • Spatenka J, Khaghani A, Irving JD, Theodoropoulos S, Slavik Z, Yacomb MH. Gianturco self-expanding metallic stents in treatment of tracheobronchial stenosis after single lung and heart and lung transplantation. Eur J Cardiothorac Surg 1991;5: 648-52.
    • (1991) Eur J Cardiothorac Surg , vol.5 , pp. 648-652
    • Spatenka, J.1    Khaghani, A.2    Irving, J.D.3    Theodoropoulos, S.4    Slavik, Z.5    Yacomb, M.H.6
  • 16
    • 34247525532 scopus 로고    scopus 로고
    • Endobronchial stent placement for the management of airway complications after lung transplantation
    • Kapoor BS, May B, Panu N, Kowalik K, Hunter DW. Endobronchial stent placement for the management of airway complications after lung transplantation. J Vasc Interv Radiol 2007;18:629-32.
    • (2007) J Vasc Interv Radiol , vol.18 , pp. 629-632
    • Kapoor, B.S.1    May, B.2    Panu, N.3    Kowalik, K.4    Hunter, D.W.5
  • 17
    • 0026479024 scopus 로고
    • Expanding wire stents in benign tracheobronchial disease: Indications and complications
    • Nashef SA, Dromer C, Velly JF, Labrousse L, Couraud L. Expanding wire stents in benign tracheobronchial disease: Indications and complications. Ann Thorac Surg 1992;54:937-40.
    • (1992) Ann Thorac Surg , vol.54 , pp. 937-940
    • Nashef, S.A.1    Dromer, C.2    Velly, J.F.3    Labrousse, L.4    Couraud, L.5
  • 18
    • 0031941595 scopus 로고    scopus 로고
    • Tracheobronchial stenting for the treatment of airway obstruction
    • Filler RM, Forte V, Chait P. Tracheobronchial stenting for the treatment of airway obstruction. J Pediatr Surg 1998;33:304-11.
    • (1998) J Pediatr Surg , vol.33 , pp. 304-311
    • Filler, R.M.1    Forte, V.2    Chait, P.3
  • 19
    • 0345633547 scopus 로고    scopus 로고
    • Tracheobronchial strictures: Treatment with a polyurethane-covered retrievable expandable nitinol stent-initial experience
    • Song HY, Shim TS, Kang SG, et al. Tracheobronchial strictures: Treatment with a polyurethane-covered retrievable expandable nitinol stent-initial experience. Radiology 1999; 213:905-12.
    • (1999) Radiology , vol.213 , pp. 905-912
    • Song, H.Y.1    Shim, T.S.2    Kang, S.G.3
  • 20
    • 0345167846 scopus 로고    scopus 로고
    • Malignant tracheobronchial strictures: Palliation with covered retrievable expandable nitinol stent
    • Shin JH, Kim SW, Shim TS, et al. Malignant tracheobronchial strictures: Palliation with covered retrievable expandable nitinol stent. J Vasc Interv Radiol 2003;14:1525-34.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1525-1534
    • Shin, J.H.1    Kim, S.W.2    Shim, T.S.3
  • 21
    • 4544308841 scopus 로고    scopus 로고
    • Results of temporary placement of covered retrievable covered nitinol stents for tuberculous bronchial strictures
    • Kim JH, Shin JH, Shim TS, et al. Results of temporary placement of covered retrievable covered nitinol stents for tuberculous bronchial strictures. J Vasc Interv Radiol 2004;15:1003-8.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1003-1008
    • Kim, J.H.1    Shin, J.H.2    Shim, T.S.3
  • 22
    • 31744446148 scopus 로고    scopus 로고
    • Malignant esophageal-tracheobronchial strictures: Parallel placement of covered retrievable expandable nitinol stents
    • Nam DH, Shin JH, Song HY, Jung GS, Han YM. Malignant esophageal- tracheobronchial strictures: Parallel placement of covered retrievable expandable nitinol stents. Acta Radiol 2006;47:3-9.
    • (2006) Acta Radiol , vol.47 , pp. 3-9
    • Nam, D.H.1    Shin, J.H.2    Song, H.Y.3    Jung, G.S.4    Han, Y.M.5
  • 23
    • 33748708262 scopus 로고    scopus 로고
    • Treatment of tracheobronchial obstruction with a polytetrafluoroethylene- covered retrievable expandable nitinol stent
    • Shin JH, Song HY, Ko GY, et al. Treatment of tracheobronchial obstruction with a polytetrafluoroethylene-covered retrievable expandable nitinol stent. J Vasc Interv Radiol 2006; 17:657-63.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 657-663
    • Shin, J.H.1    Song, H.Y.2    Ko, G.Y.3
  • 24
    • 33947668892 scopus 로고    scopus 로고
    • Benign tracheobronchial strictures: Long-term results and factors affecting airway patency after temporary stent placement
    • Kim JH, Shin JH, Song HY, Shim TS, Yoon CJ, Ko GY. Benign tracheobronchial strictures: Long-term results and factors affecting airway patency after temporary stent placement. AJR Am J Roentgenol 2007;188:1033-8.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1033-1038
    • Kim, J.H.1    Shin, J.H.2    Song, H.Y.3    Shim, T.S.4    Yoon, C.J.5    Ko, G.Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.