메뉴 건너뛰기




Volumn 8367, Issue , 2012, Pages

Development and testing of a fluorescence biosensor for glucose sensing

Author keywords

concanavalin A.; continuous glucose monitoring system; Fluorescence resonance energy transfer; glucose biosensor

Indexed keywords

COMPETITIVE BINDING; CONCANAVALIN A; CONTINUOUS GLUCOSE MONITORING; DEVELOPMENT AND TESTING; DIABETES MELLITUS; DONOR CONCENTRATIONS; FLUORESCENCE BIOSENSORS; FLUORESCENCE RESONANCE ENERGY TRANSFER; GLUCOSE BIOSENSOR; GLUCOSE CONCENTRATION; GLUCOSE LEVEL; GLUCOSE MEASUREMENTS; GLUCOSE SENSING; HIGH SENSITIVITY; IMPLANTABLE BIOSENSORS; INTENSIVE CARE; LONG WAVELENGTH; POLYMER LAYERS; PREDICTION ACCURACY; RESONANCE ENERGY TRANSFER; TEST METHOD;

EID: 84874688264     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.920699     Document Type: Conference Paper
Times cited : (3)

References (28)
  • 1
    • 84882439029 scopus 로고    scopus 로고
    • Diabetes
    • WHO Trans. Media Centre
    • WHO. "Diabetes." Fact sheet: World Health Organization, Trans. Media Centre (2011) from http://www.who.int/diabetes/en/index.html
    • (2011) Fact Sheet: World Health Organization
  • 2
    • 0004694873 scopus 로고    scopus 로고
    • NIH. National Diabetes Statistics U.S. Department of Health and Human Services
    • NIH. National Diabetes Statistics. National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). U.S. Department of Health and Human Services (2011) from http://diabetes.niddk.nih.gov/dm/pubs/statistics/
    • (2011) National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
  • 3
    • 84874740606 scopus 로고    scopus 로고
    • Living with diabetes
    • ADA
    • ADA. "Living with Diabetes." American Diabetes Association from http://www.diabetes.org/living-with-diabetes/treatment-and-care/blood-glucose- control/checking-your-bloodglucose.Html
    • American Diabetes Association
  • 4
    • 79952581810 scopus 로고    scopus 로고
    • Finger pricking and pain: A never ending story
    • Heinemann L. "Finger Pricking and Pain: A Never Ending Story." J Diabetes Sci. Technol.; 2(5): 919-921 (2008).
    • (2008) J Diabetes Sci. Technol , vol.2 , Issue.5 , pp. 919-921
    • Heinemann, L.1
  • 5
    • 4344692198 scopus 로고    scopus 로고
    • Current problems and potential techniques in in vivo monitoring
    • Wickramasinghe Y, Yang Y, and Spencer S. "Current Problems and Potential Techniques in In Vivo Monitoring." J Fluorescence; 14(5): 513-520 (2004).
    • (2004) J Fluorescence , vol.14 , Issue.5 , pp. 513-520
    • Wickramasinghe, Y.1    Yang, Y.2    Spencer, S.3
  • 6
    • 4344679385 scopus 로고    scopus 로고
    • Fluorescence glucose detection: Advances toward the ideal in vivo biosensor
    • Moschou. E, Sharma B, Deo S, and Daunert S. "Fluorescence Glucose Detection: Advances toward the Ideal In Vivo Biosensor." J Fluorescence; 14(5): 535-547 (2004).
    • (2004) J Fluorescence , vol.14 , Issue.5 , pp. 535-547
    • Moschou, E.1    Sharma, B.2    Deo, S.3    Daunert, S.4
  • 7
    • 0032799808 scopus 로고    scopus 로고
    • A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel
    • DOI 10.1021/ac990060r
    • Russell R, Pishko M, Gefrides C, McShane M, and Coté G. "A Fluorescence-Based Glucose Biosensor Using ConA and Dextran Encapsulated in a Poly(ethylene glycol) Hydrogel." Anal. Chem.; 71:3126-32 (1999). (Pubitemid 29372728)
    • (1999) Analytical Chemistry , vol.71 , Issue.15 , pp. 3126-3132
    • Russell, R.J.1    Pishko, M.V.2    Gefrides, C.C.3    McShane, M.J.4    Cote, G.L.5
  • 8
    • 27544434392 scopus 로고    scopus 로고
    • Competitive binding assay for glucose based on glycodendrimer-fluorophore conjugates
    • DOI 10.1021/ac0507901
    • Ibey B, Beier H, Rounds R, Coté G, Yadavalli V, and Pishko M. "Competitive Binding Assay for Glucose Based on Glycodendrimer-Fluorophore Conjugates." Anal. Chem.; 77: 7039-7046 (2005). (Pubitemid 41547303)
    • (2005) Analytical Chemistry , vol.77 , Issue.21 , pp. 7039-7046
    • Ibey, B.L.1    Beier, H.T.2    Rounds, R.M.3    Cote, G.L.4    Yadavalli, V.K.5    Pishko, M.V.6
  • 9
    • 84865538780 scopus 로고    scopus 로고
    • Fluorescence-based glucose sensors." chapter 10
    • Ed. David Cunningham and Julie Stenken. Chemical Analysis: Monographs on Analytical Chemistry and its Application. Hoboken, NJ, John Wiley & Sons, Inc
    • McShane M, Stein E. "Fluorescence-Based Glucose Sensors." Chapter 10, In Vivo Glucose Sensing. Ed. David Cunningham and Julie Stenken. Chemical Analysis: Monographs on Analytical Chemistry and its Application. Hoboken, NJ, John Wiley & Sons, Inc.; Vol. 174 (2010).
    • (2010) Vivo Glucose Sensing , vol.174
    • McShane, M.1    Stein, E.2
  • 11
    • 0020037173 scopus 로고
    • Affinity sensor: A new technique for developing implantable sensors for glucose and other metabolites
    • Schultz J, Mansouri S, and Goldstein I. "Affinity Sensor: A New Technique for Developing Implantable Sensors for Glucose and Other Metabolites." Diabetes Care; 5(3): 245-253 (1982). (Pubitemid 12117174)
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 245-253
    • Schultz, J.S.1    Mansouri, S.2    Goldstein, I.J.3
  • 12
    • 0000407406 scopus 로고
    • Fiber-optic biosensors based on fluorescence energy transfer
    • Meadows D and Shultz J. "Fiber-Optic Biosensors Based on Fluorescence Energy Transfer." Talanta; 35(2): 145-150 (1988).
    • (1988) Talanta , vol.35 , Issue.2 , pp. 145-150
    • Meadows, D.1    Shultz, J.2
  • 13
    • 0033663638 scopus 로고    scopus 로고
    • Glucose monitoring using implanted fluorescent microspheres
    • McShane M, Russell R, Pishko M, and Coté G. "Glucose Monitoring Using Implanted Fluorescent Microspheres." IEEE Engg. Med. & Biol.; 19(6): 36-45 (2000).
    • (2000) IEEE Engg. Med. & Biol , vol.19 , Issue.6 , pp. 36-45
    • McShane, M.1    Russell, R.2    Pishko, M.3    Coté, G.4
  • 14
    • 84874694084 scopus 로고    scopus 로고
    • Implantable concanavalin a based sensors for interstitial fluid glucose sensing in diabetics
    • Ed. Chris Geddes and Joseph Lakowicz. New York
    • Ibey B, Pishko M., and Coté G. "Implantable Concanavalin A Based Sensors for Interstitial Fluid Glucose Sensing in Diabetics." Chapter 4, Glucose Sensing-Topics in Fluorescence Spectroscopy. Ed. Chris Geddes and Joseph Lakowicz. New York; 11:105 (2006).
    • (2006) Chapter 4, Glucose Sensing-Topics in Fluorescence Spectroscopy , vol.11 , pp. 105
    • Ibey, B.1    Pishko, M.2    Coté, G.3
  • 16
    • 1042275717 scopus 로고    scopus 로고
    • In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring
    • DOI 10.1016/j.bios.2003.08.019
    • Ballerstadt R, Polak A, Beuhler A, Frye J. "In Vitro Long-Term Performance Study of a Near-Infrared Fluorescence Affinity Sensor for Glucose Monitoring." Biosensors and Bioelectronics; 19: 905-914 (2004). (Pubitemid 38201341)
    • (2004) Biosensors and Bioelectronics , vol.19 , Issue.8 , pp. 905-914
    • Ballerstadt, R.1    Polak, A.2    Beuhler, A.3    Frye, J.4
  • 17
  • 18
    • 37649003074 scopus 로고    scopus 로고
    • Reusable optical platform with permeability-controlled hydrogel pads for selective saccharide detection
    • Cheung K, Mak W, and Trau D. "Reusable Optical Platform with Permeability-Controlled Hydrogel Pads for Selective Saccharide Detection." Anal. Chemica. Actuators; 607:204-210 (2008).
    • (2008) Anal. Chemica. Actuators , vol.607 , pp. 204-210
    • Cheung, K.1    Mak, W.2    Trau, D.3
  • 19
    • 84862110783 scopus 로고    scopus 로고
    • Development of smart contact lenses for ophthalmic glucose monitoring
    • Ed. Chris Geddes. New York, NY: Springer, Inc
    • Badugu R, Lakowicz J, Geddes C. "Development of Smart Contact Lenses for Ophthalmic Glucose Monitoring." Glucose Sensing. Ed. Chris Geddes. New York, NY, Springer, Inc. 11:399-429 (2006).
    • (2006) Glucose Sensing , vol.11 , pp. 399-429
    • Badugu, R.1    Lakowicz, J.2    Geddes, C.3
  • 20
    • 58549099502 scopus 로고    scopus 로고
    • Development of boronic acid grafted random copolymer sensing fluid for continuous glucose monitoring
    • Li S, Davis E, Anderson J, Lin Q, and Wang Q. "Development of Boronic Acid Grafted Random Copolymer Sensing Fluid for Continuous Glucose Monitoring." Biomacromolecules; 10(1):113-118 (2009).
    • (2009) Biomacromolecules , vol.10 , Issue.1 , pp. 113-118
    • Li, S.1    Davis, E.2    Anderson, J.3    Lin, Q.4    Wang, Q.5
  • 22
    • 84874740606 scopus 로고    scopus 로고
    • Living with diabetes
    • ADA
    • ADA. "Living with Diabetes." American Diabetes Association. From http://www.diabetes.org/living-with-diabetes/treatment-and-care/blood- glucose-control/checking-your-bloodglucose.html
    • American Diabetes Association
  • 24
    • 84874755408 scopus 로고    scopus 로고
    • Immobilization chemistry of biological recognition
    • Ed. Electra Gizeli and Christopher Lowe Taylor & Francis; New York
    • Mayes A. "Immobilization Chemistry of Biological Recognition." Chapter 4, Biomolecular Sensors. Ed. Electra Gizeli and Christopher Lowe. Taylor & Francis; New York (2002).
    • (2002) Chapter 4, Biomolecular Sensors
    • Mayes, A.1
  • 25
    • 79960220835 scopus 로고    scopus 로고
    • NIR FRET fluorescence for use as an implantable glucose biosensor
    • Dweik M, and Grant S. "NIR FRET Fluorescence for Use as an Implantable Glucose Biosensor." Sensors & Transducers J; 3: 71-79 (2008).
    • (2008) Sensors & Transducers J , vol.3 , pp. 71-79
    • Dweik, M.1    Grant, S.2
  • 26
    • 0034005547 scopus 로고    scopus 로고
    • Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer
    • Tang Z, Du Xiaogu, Louie R, and Kost G. "Effects of Drugs on Glucose Measurements with Handheld glucose Meters and a Portable Glucose Analyzer." Am. J. Clin. Pathol.; 113: 75-86 (2000). (Pubitemid 30217342)
    • (2000) American Journal of Clinical Pathology , vol.113 , Issue.1 , pp. 75-86
    • Tang, Z.1    Du, X.2    Louie, R.F.3    Kost, G.J.4
  • 27
    • 77957373315 scopus 로고    scopus 로고
    • Multivalent interaction based carbohydrate biosensors for signal amplification
    • Wang Y, Chalagalla S, Li T, Sun X, Zhao W, Wang P, and Zeng W. "Multivalent Interaction Based Carbohydrate Biosensors for Signal Amplification." Biosens Bioelectron; 26(3): 996-1001 (2010).
    • (2010) Biosens Bioelectron , vol.26 , Issue.3 , pp. 996-1001
    • Wang, Y.1    Chalagalla, S.2    Li, T.3    Sun, X.4    Zhao, W.5    Wang, P.6    Zeng, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.