메뉴 건너뛰기




Volumn 28, Issue 3, 2013, Pages 521-525

Cement-in-Cement Revision for Selected Vancouver Type B1 Femoral Periprosthetic Fractures: A Biomechanical Analysis

Author keywords

Cement in cement revision; Periprosthetic fracture; Total hip replacement

Indexed keywords

CEMENT;

EID: 84874558451     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2012.08.016     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 75649091164 scopus 로고    scopus 로고
    • Temporal trends in hip and knee replacement in the United Kingdom: 1991 to 2006
    • Culliford D.J., Maskell J., Beard D.J., et al. Temporal trends in hip and knee replacement in the United Kingdom: 1991 to 2006. J Bone Joint Surg Br 2010, 92(1):130.
    • (2010) J Bone Joint Surg Br , vol.92 , Issue.1 , pp. 130
    • Culliford, D.J.1    Maskell, J.2    Beard, D.J.3
  • 2
    • 34147150632 scopus 로고    scopus 로고
    • Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030
    • Kurtz S., Ong K., Lau E., et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007, 89(4):780.
    • (2007) J Bone Joint Surg Am , vol.89 , Issue.4 , pp. 780
    • Kurtz, S.1    Ong, K.2    Lau, E.3
  • 4
    • 65649100806 scopus 로고    scopus 로고
    • Revision of the cemented femoral stem using a cement-in-cement technique: a five- to 15-year review
    • Duncan W.W., Hubble M.J., Howell J.R., et al. Revision of the cemented femoral stem using a cement-in-cement technique: a five- to 15-year review. J Bone Joint Surg Br 2009, 91(5):577.
    • (2009) J Bone Joint Surg Br , vol.91 , Issue.5 , pp. 577
    • Duncan, W.W.1    Hubble, M.J.2    Howell, J.R.3
  • 5
    • 33745671618 scopus 로고    scopus 로고
    • In-cement technique for revision hip arthroplasty
    • Quinlan J.F., O'Shea K., Doyle F., et al. In-cement technique for revision hip arthroplasty. J Bone Joint Surg Br 2006, 88(6):730.
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.6 , pp. 730
    • Quinlan, J.F.1    O'Shea, K.2    Doyle, F.3
  • 6
    • 67449104501 scopus 로고    scopus 로고
    • Femoral cement within cement technique in carefully selected aseptic revision arthroplasties
    • Marcos L., Buttaro M., Comba F., et al. Femoral cement within cement technique in carefully selected aseptic revision arthroplasties. Int Orthop 2009, 33(3):633.
    • (2009) Int Orthop , vol.33 , Issue.3 , pp. 633
    • Marcos, L.1    Buttaro, M.2    Comba, F.3
  • 7
    • 34848913465 scopus 로고    scopus 로고
    • Cement-within-cement stem exchange using the collarless polished double-taper stem
    • Mandziak D.G., Howie D.W., Neale S.D., et al. Cement-within-cement stem exchange using the collarless polished double-taper stem. J Arthroplasty 2007, 22(7):1000.
    • (2007) J Arthroplasty , vol.22 , Issue.7 , pp. 1000
    • Mandziak, D.G.1    Howie, D.W.2    Neale, S.D.3
  • 8
    • 53649088009 scopus 로고    scopus 로고
    • Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique
    • Goto K., Kawanabe K., Akiyama H., et al. Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique. J Bone Joint Surg Br 2008, 90(8):1013.
    • (2008) J Bone Joint Surg Br , vol.90 , Issue.8 , pp. 1013
    • Goto, K.1    Kawanabe, K.2    Akiyama, H.3
  • 9
    • 53149091235 scopus 로고    scopus 로고
    • Cement-in-cement revision hip arthroplasty: an analysis of clinical and biomechanical literature
    • Keeling P., Prendergast P.J., Lennon A.B., et al. Cement-in-cement revision hip arthroplasty: an analysis of clinical and biomechanical literature. Arch Orthop Trauma Surg 2008, 128(10):1193.
    • (2008) Arch Orthop Trauma Surg , vol.128 , Issue.10 , pp. 1193
    • Keeling, P.1    Prendergast, P.J.2    Lennon, A.B.3
  • 10
    • 70450207332 scopus 로고    scopus 로고
    • Cement-in-cement stem revision for Vancouver type B periprosthetic femoral fractures after total hip arthroplasty
    • Briant-Evans T.W., Veeramootoo D., Tsiridis E., et al. Cement-in-cement stem revision for Vancouver type B periprosthetic femoral fractures after total hip arthroplasty. Acta Orthop 2009, 80(5):548.
    • (2009) Acta Orthop , vol.80 , Issue.5 , pp. 548
    • Briant-Evans, T.W.1    Veeramootoo, D.2    Tsiridis, E.3
  • 11
    • 78751582017 scopus 로고    scopus 로고
    • Cement-in-cement femoral revision for the treatment of highly selected Vancouver B2 periprosthetic fractures
    • Richards C.J., Duncan C.P., Crawford R.W. Cement-in-cement femoral revision for the treatment of highly selected Vancouver B2 periprosthetic fractures. J Arthroplasty 2011, 26(2):335.
    • (2011) J Arthroplasty , vol.26 , Issue.2 , pp. 335
    • Richards, C.J.1    Duncan, C.P.2    Crawford, R.W.3
  • 12
    • 43049099294 scopus 로고    scopus 로고
    • Biomechanical evaluation of periprosthetic femoral fracture fixation
    • Zdero R., Walker R., Waddell J.P., et al. Biomechanical evaluation of periprosthetic femoral fracture fixation. J Bone Joint Surg Am 2008, 90(5):1068.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.5 , pp. 1068
    • Zdero, R.1    Walker, R.2    Waddell, J.P.3
  • 13
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques
    • Dennis M.G., Simon J.A., Kummer F.J., et al. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 2000, 15(4):523.
    • (2000) J Arthroplasty , vol.15 , Issue.4 , pp. 523
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3
  • 14
    • 33744503191 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates
    • Fulkerson E., Koval K., Preston C.F., et al. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates. J Orthop Trauma 2006, 20(2):89.
    • (2006) J Orthop Trauma , vol.20 , Issue.2 , pp. 89
    • Fulkerson, E.1    Koval, K.2    Preston, C.F.3
  • 15
    • 0035286601 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques
    • Dennis M.G., Simon J.A., Kummer F.J., et al. Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques. J Orthop Trauma 2001, 15(3):177.
    • (2001) J Orthop Trauma , vol.15 , Issue.3 , pp. 177
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3
  • 16
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G., Deuretzbacher G., Heller M., et al. Hip contact forces and gait patterns from routine activities. J Biomech 2001, 34(7):859.
    • (2001) J Biomech , vol.34 , Issue.7 , pp. 859
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 17
    • 0029410935 scopus 로고
    • Torsional loads in the early postoperative period following total hip replacement
    • Kotzar G.M., Davy D.T., Berilla J., et al. Torsional loads in the early postoperative period following total hip replacement. J Orthop Res 1995, 13(6):945.
    • (1995) J Orthop Res , vol.13 , Issue.6 , pp. 945
    • Kotzar, G.M.1    Davy, D.T.2    Berilla, J.3
  • 18
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G., Graichen F., Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech 1993, 26(8):969.
    • (1993) J Biomech , vol.26 , Issue.8 , pp. 969
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 19
    • 84857726933 scopus 로고    scopus 로고
    • Treatment of periprosthetic femoral fractures in hip arthroplasty
    • Park S.K., Kim Y.G., Kim S.Y. Treatment of periprosthetic femoral fractures in hip arthroplasty. Clin Orthop Surg 2011, 3(2):101.
    • (2011) Clin Orthop Surg , vol.3 , Issue.2 , pp. 101
    • Park, S.K.1    Kim, Y.G.2    Kim, S.Y.3
  • 20
    • 0017844886 scopus 로고
    • Points in the technique of recementing in the revision of an implant arthroplasty
    • Greenwald A.S., Narten N.C., Wilde A.H. Points in the technique of recementing in the revision of an implant arthroplasty. J Bone Joint Surg Br 1978, 60(1):107.
    • (1978) J Bone Joint Surg Br , vol.60 , Issue.1 , pp. 107
    • Greenwald, A.S.1    Narten, N.C.2    Wilde, A.H.3
  • 21
    • 33947725271 scopus 로고    scopus 로고
    • Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty
    • Weinrauch P.C., Bell C., Wilson L., et al. Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty. J Arthroplasty 2007, 22(3):394.
    • (2007) J Arthroplasty , vol.22 , Issue.3 , pp. 394
    • Weinrauch, P.C.1    Bell, C.2    Wilson, L.3
  • 22
    • 67650763724 scopus 로고    scopus 로고
    • In vitro cyclic testing of the Exeter stem after cement within cement revision
    • Wilson L.J., Bell C.G., Weinrauch P., et al. In vitro cyclic testing of the Exeter stem after cement within cement revision. J Arthroplasty 2009, 24(5):789.
    • (2009) J Arthroplasty , vol.24 , Issue.5 , pp. 789
    • Wilson, L.J.1    Bell, C.G.2    Weinrauch, P.3
  • 23
    • 0029843646 scopus 로고    scopus 로고
    • Cement-within-cement revision hip arthroplasty; should it be done?
    • Li P.L., Ingle P.J., Dowell J.K. Cement-within-cement revision hip arthroplasty; should it be done?. J Bone Joint Surg Br 1996, 78(5):809.
    • (1996) J Bone Joint Surg Br , vol.78 , Issue.5 , pp. 809
    • Li, P.L.1    Ingle, P.J.2    Dowell, J.K.3
  • 24
    • 84875867519 scopus 로고    scopus 로고
    • Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study
    • Thomsen M.N., Jakubowitz E., Seeger J.B., et al. Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study. Orthopedics 2008, 31(7):653.
    • (2008) Orthopedics , vol.31 , Issue.7 , pp. 653
    • Thomsen, M.N.1    Jakubowitz, E.2    Seeger, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.