메뉴 건너뛰기




Volumn 6, Issue 1, 2013, Pages 48-57

Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography

Author keywords

Aortic valve; Echocardiography; Mitral valve; MRI; Regurgitation

Indexed keywords

ADULT; AGED; AORTA SINUS; AORTA VALVE REGURGITATION; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; ECHOCARDIOGRAPH; FEMALE; FOLLOW UP; HEART STROKE VOLUME; HUMAN; LONGITUDINAL STUDY; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REGURGITATION; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; PROSPECTIVE STUDY; SINGLE BLIND PROCEDURE; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPARATIVE STUDY; DIFFERENTIAL DIAGNOSIS; DOPPLER ECHOCARDIOGRAPHY; HEART LEFT VENTRICLE FUNCTION; METHODOLOGY; MIDDLE AGED; MULTICENTER STUDY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOPHYSIOLOGY; PHYSIOLOGY; PROGNOSIS; RECEIVER OPERATING CHARACTERISTIC; SEVERITY OF ILLNESS INDEX;

EID: 84874529806     PISSN: 19419651     EISSN: 19420080     Source Type: Journal    
DOI: 10.1161/CIRCIMAGING.112.975623     Document Type: Article
Times cited : (200)

References (23)
  • 4
    • 49349116544 scopus 로고    scopus 로고
    • Effect of dynamic fow rate and orifce area on mitral regurgitant stroke volume quantifcation using the proximal isovelocity surface area method
    • Buck T, Plicht B, Kahlert P, Schenk IM, Hunold P, Erbel R. Effect of dynamic fow rate and orifce area on mitral regurgitant stroke volume quantifcation using the proximal isovelocity surface area method. J Am Coll Cardiol. 2008;52:767-778.
    • (2008) J Am Coll Cardiol. , vol.52 , pp. 767-778
    • Buck, T.1    Plicht, B.2    Kahlert, P.3    Schenk, I.M.4    Hunold, P.5    Erbel, R.6
  • 6
    • 7044286097 scopus 로고    scopus 로고
    • Quantifcation of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: Comparison of techniques
    • Kon MW, Myerson SG, Moat NE, Pennell DJ. Quantifcation of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: comparison of techniques. J Heart Valve Dis. 2004;13:600-607.
    • (2004) J Heart Valve Dis. , vol.13 , pp. 600-607
    • Kon, M.W.1    Myerson, S.G.2    Moat, N.E.3    Pennell, D.J.4
  • 7
    • 34147127099 scopus 로고    scopus 로고
    • Evaluation of aortic regurgitation in congenital heart disease: Value of MR imaging in comparison to echocardiography
    • Ley S, Eichhorn J, Ley-Zaporozhan J, Ulmer H, Schenk JP, Kauczor HU, Arnold R. Evaluation of aortic regurgitation in congenital heart disease: value of MR imaging in comparison to echocardiography. Pediatr Radiol. 2007;37:426-436.
    • (2007) Pediatr Radiol. , vol.37 , pp. 426-436
    • Ley, S.1    Eichhorn, J.2    Ley-Zaporozhan, J.3    Ulmer, H.4    Schenk, J.P.5    Kauczor, H.U.6    Arnold, R.7
  • 8
    • 60549090789 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance imaging for valvular heart disease: Technique and validation
    • Cawley PJ, Maki JH, Otto CM. Cardiovascular magnetic resonance imaging for valvular heart disease: technique and validation. Circulation. 2009;119:468-478.
    • (2009) Circulation. , vol.119 , pp. 468-478
    • Cawley, P.J.1    Maki, J.H.2    Otto, C.M.3
  • 12
    • 0023678744 scopus 로고
    • Experimental validation of Doppler echocardiographic measurement of volume fow through the stenotic aortic valve
    • Otto CM, Pearlman AS, Gardner CL, Enomoto DM, Togo T, Tsuboi H, Ivey TD. Experimental validation of Doppler echocardiographic measurement of volume fow through the stenotic aortic valve. Circulation. 1988;78:435-441.
    • (1988) Circulation. , vol.78 , pp. 435-441
    • Otto, C.M.1    Pearlman, A.S.2    Gardner, C.L.3    Enomoto, D.M.4    Togo, T.5    Tsuboi, H.6    Ivey, T.D.7
  • 13
    • 0026342728 scopus 로고
    • Doppler echocardiographic fndings in adults with severe symptomatic valvular aortic stenosis: Balloon Valvuloplasty Registry Echocardiographers
    • Otto CM, Nishimura RA, Davis KB, Kisslo KB, Bashore TM. Doppler echocardiographic fndings in adults with severe symptomatic valvular aortic stenosis: Balloon Valvuloplasty Registry Echocardiographers. Am J Cardiol. 1991;68:1477-1484.
    • (1991) Am J Cardiol. , vol.68 , pp. 1477-1484
    • Otto, C.M.1    Nishimura, R.A.2    Davis, K.B.3    Kisslo, K.B.4    Bashore, T.M.5
  • 14
    • 0021173362 scopus 로고
    • Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: Clinical validation of two new methods using the apical window
    • Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation. 1984;70:425-431.
    • (1984) Circulation. , vol.70 , pp. 425-431
    • Lewis, J.F.1    Kuo, L.C.2    Nelson, J.G.3    Limacher, M.C.4    Quinones, M.A.5
  • 15
    • 0026737780 scopus 로고
    • Severity of aortic regurgitation: Interstudy reproducibility of measurements with velocity-encoded cine MR imaging
    • Dulce MC, Mostbeck GH, O'Sullivan M, Cheitlin M, Caputo GR, Higgins CB. Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging. Radiology. 1992;185:235-240.
    • (1992) Radiology. , vol.185 , pp. 235-240
    • Dulce, M.C.1    Mostbeck, G.H.2    O'Sullivan, M.3    Cheitlin, M.4    Caputo, G.R.5    Higgins, C.B.6
  • 18
    • 0032521414 scopus 로고    scopus 로고
    • Comparison of quantitative Doppler with magnetic resonance imaging for assessment of the severity of mitral regurgitation
    • Kizilbash AM, Hundley WG, Willett DL, Franco F, Peshock RM, Gray-burn PA. Comparison of quantitative Doppler with magnetic resonance imaging for assessment of the severity of mitral regurgitation. Am J Car-diol. 1998;81:792-795.
    • (1998) Am J Car-diol. , vol.81 , pp. 792-795
    • Kizilbash, A.M.1    Hundley, W.G.2    Willett, D.L.3    Franco, F.4    Peshock, R.M.5    Gray-Burn, P.A.6
  • 22
    • 0242551318 scopus 로고    scopus 로고
    • Color fow imaging of the vena contracta in mitral regurgitation: Technical considerations
    • Roberts BJ, Grayburn PA. Color fow imaging of the vena contracta in mitral regurgitation: technical considerations. J Am Soc Echocardiogr. 2003;16:1002-1006.
    • (2003) J Am Soc Echocardiogr. , vol.16 , pp. 1002-1006
    • Roberts, B.J.1    Grayburn, P.A.2
  • 23
    • 77649241509 scopus 로고    scopus 로고
    • Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity
    • Biner S, Rafque A, Rafi F, Tolstrup K, Noorani O, Shiota T, Gurudevan S, Siegel RJ. Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity. JACC Cardiovasc Imaging. 2010;3:235-243.
    • (2010) JACC Cardiovasc Imaging. , vol.3 , pp. 235-243
    • Biner, S.1    Rafque, A.2    Rafi, F.3    Tolstrup, K.4    Noorani, O.5    Shiota, T.6    Gurudevan, S.7    Siegel, R.J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.