-
2
-
-
0024567030
-
Forced use of hemiplegic upper extremities to reverse the effect of learned nonuse among chronic stroke and head-injured patients
-
[PMID:2707361]
-
Wolf SL, Lecraw DE, Barton LA, Jann BB. Forced use of hemiplegic upper extremities to reverse the effect of learned nonuse among chronic stroke and head-injured patients. Exp Neurol. 1989;104(2):125-132. [PMID:2707361]http://dx.doi.org/10.1016/S0014-4886(89)80005-6.
-
(1989)
Exp Neurol
, vol.104
, Issue.2
, pp. 125-132
-
-
Wolf, S.L.1
Lecraw, D.E.2
Barton, L.A.3
Jann, B.B.4
-
3
-
-
0034785252
-
Implantable Neuroprosthesis Research Group. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: A multicenter study
-
[PMID:11588741]
-
Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, Gorman P, Hobby J, Mulcahey MJ, Car-roll S, Hentz VR, Wiegner A; Implantable Neuroprosthesis Research Group. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Arch Phys Med Rehabil. 2001;82(10):1380-1388.[PMID:11588741]http://dx.doi.org/10.1053/apmr.2001.25910.
-
(2001)
Arch Phys Med Rehabil
, vol.82
, Issue.10
, pp. 1380-1388
-
-
Peckham, P.H.1
Keith, M.W.2
Kilgore, K.L.3
Grill, J.H.4
Wuolle, K.S.5
Thrope, G.B.6
Gorman, P.7
Hobby, J.8
Mulcahey, M.J.9
Car-Roll, S.10
Hentz, V.R.11
Wiegner, A.12
-
4
-
-
41749090273
-
An implanted upper-extremity neuroprosthe-sis using myoelectric control
-
[PMID:18406958]
-
Kilgore KL, Hoyen HA, Bryden AM, Hart RL, Keith MW, Peckham PH. An implanted upper-extremity neuroprosthe-sis using myoelectric control. J Hand Surg Am. 2008;33(4):539-550. [PMID:18406958]http://dx.doi.org/10.1016/j.jhsa.2008.01.007
-
(2008)
J Hand Surg Am
, vol.33
, Issue.4
, pp. 539-550
-
-
Kilgore, K.L.1
Hoyen, H.A.2
Bryden, A.M.3
Hart, R.L.4
Keith, M.W.5
Peckham, P.H.6
-
5
-
-
84973432709
-
A neuroprosthesis for restoring arm and hand function via functional electrical stimulation following high cervical spinal cord injury
-
Nov 10-14; Philadelphia, PA
-
Kirsch RF, Polasek KH, Hoyen HA, Memberg WD, Wil-liams MR. A neuroprosthesis for restoring arm and hand function via functional electrical stimulation following high cervical spinal cord injury. Proceedings of the 12th Annual Conference of the International Functional Electrical Stimu-lation Society; 2007 Nov 10-14; Philadelphia, PA.
-
(2007)
Proceedings of the 12th Annual Conference of the International Functional Electrical Stimu-lation Society
-
-
Kirsch, R.F.1
Polasek, K.H.2
Hoyen, H.A.3
Memberg, W.D.4
Wil-Liams, M.R.5
-
6
-
-
84860227134
-
Stimulation for return of function after stroke
-
Krames ES, Peckham PH, Rezai AR, editors, London (UK): Academic Press
-
Chae J, Knutson J, Sheffler LR. Stimulation for return of function after stroke. In: Krames ES, Peckham PH, Rezai AR, editors. Neuromodulation. London (UK): Academic Press; 2009. p. 743-751.
-
(2009)
Neuromodulation
, pp. 743-751
-
-
Chae, J.1
Knutson, J.2
Sheffler, L.R.3
-
7
-
-
77649207032
-
Assessing the reliability of the Modified Modified Ashworth Scale between two physiotherapists in adult patients with hemiplegia
-
[PMID:20037215]
-
Ansari NN, Naghdi S, Hasson S, Fakhari Z, Mashayekhi M, Herasi M. Assessing the reliability of the Modified Modified Ashworth Scale between two physiotherapists in adult patients with hemiplegia. NeuroRehabilitation. 2009;25(4):235-240. [PMID:20037215]
-
(2009)
NeuroRehabilitation
, vol.25
, Issue.4
, pp. 235-240
-
-
Ansari, N.N.1
Naghdi, S.2
Hasson, S.3
Fakhari, Z.4
Mashayekhi, M.5
Herasi, M.6
-
8
-
-
79951651181
-
Design and testing of an advanced implantable neuro-prosthesis with myoelectric control
-
[PMID:20876029]
-
Hart RL, Bhadra N, Montague FW, Kilgore KL, Peckham PH. Design and testing of an advanced implantable neuro-prosthesis with myoelectric control. IEEE Trans Neural Syst Rehabil Eng. 2011;19(1):45-53. [PMID:20876029]http://dx.doi.org/10.1109/TNSRE.2010.2079952.
-
(2011)
IEEE Trans Neural Syst Rehabil Eng
, vol.19
, Issue.1
, pp. 45-53
-
-
Hart, R.L.1
Bhadra, N.2
Montague, F.W.3
Kilgore, K.L.4
Peckham, P.H.5
-
9
-
-
0028443013
-
A surgically implanted intramuscular electrode for an implantable neu-romuscular stimulation system
-
Memberg WD, Peckham PH, Keith MW. A surgically implanted intramuscular electrode for an implantable neu-romuscular stimulation system. IEEE Trans Rehabil Eng. 1994;2:80-91. http://dx.doi.org/10.1109/86.313149.
-
(1994)
IEEE Trans Rehabil Eng
, vol.2
, pp. 80-91
-
-
Memberg, W.D.1
Peckham, P.H.2
Keith, M.W.3
-
10
-
-
0029325798
-
Hand opening by electrical stimulation in patients with spastic hemiplegia
-
Hines AE, Crago PE, Billian C. Hand opening by electrical stimulation in patients with spastic hemiplegia. IEEE Trans Rehabil Eng. 1995;3:193-205.http://dx.doi.org/10.1109/86.392368.
-
(1995)
IEEE Trans Rehabil Eng
, vol.3
, pp. 193-205
-
-
Hines, A.E.1
Crago, P.E.2
Billian, C.3
-
11
-
-
0037587228
-
Intramuscular hand neuroprosthesis for chronic stroke survivors
-
[PMID:12814056]
-
Chae J, Hart R. Intramuscular hand neuroprosthesis for chronic stroke survivors. Neurorehabil Neural Repair. 2003;17(2):109-117. [PMID:12814056]http://dx.doi.org/10.1177/0888439003017002005.
-
(2003)
Neurorehabil Neural Repair
, vol.17
, Issue.2
, pp. 109-117
-
-
Chae, J.1
Hart, R.2
-
12
-
-
0033742220
-
The effects of ipsilateral forearm movement and contralateral hand grasp on the spastic hand opened by electrical stimulation
-
[PMID:11272476]
-
Lin C. The effects of ipsilateral forearm movement and contralateral hand grasp on the spastic hand opened by electrical stimulation. Neurorehabil Neural Repair. 2000; 14(3):199-205. [PMID:11272476]
-
(2000)
Neurorehabil Neural Repair
, vol.14
, Issue.3
, pp. 199-205
-
-
Lin, C.1
-
13
-
-
0024399256
-
Implantable functional neuromuscular stimulation in the tetraplegic hand
-
[PMID:2786897]
-
Keith MW, Peckham PH, Thrope GB, Stroh KC, Smith B, Buckett JR, Kilgore KL, Jatich JW. Implantable functional neuromuscular stimulation in the tetraplegic hand. J Hand Surg Am. 1989;14(3):524-530. [PMID:2786897]http://dx.doi.org/10.1016/S0363-5023(89)80017-6.
-
(1989)
J Hand Surg Am
, vol.14
, Issue.3
, pp. 524-530
-
-
Keith, M.W.1
Peckham, P.H.2
Thrope, G.B.3
Stroh, K.C.4
Smith, B.5
Buckett, J.R.6
Kilgore, K.L.7
Jatich, J.W.8
-
14
-
-
0030928088
-
An implanted upper-extremity neuroprosthesis. Follow-up of five patients
-
[PMID:9111397]
-
Kilgore KL, Peckham PH, Keith MW, Thrope GB, Wuolle KS, Bryden AM, Hart RL. An implanted upper-extremity neuroprosthesis. Follow-up of five patients. J Bone Joint Surg Am. 1997;79(4):533-541. [PMID:9111397]
-
(1997)
J Bone Joint Surg Am
, vol.79
, Issue.4
, pp. 533-541
-
-
Kilgore, K.L.1
Peckham, P.H.2
Keith, M.W.3
Thrope, G.B.4
Wuolle, K.S.5
Bryden, A.M.6
Hart, R.L.7
-
15
-
-
0024695173
-
Synthesis of hand grasp using functional neuromuscular stimulation
-
[PMID:2787284]
-
Kilgore KL, Peckham PH, Thrope GB, Keith MW, Galla-her-Stone KA. Synthesis of hand grasp using functional neuromuscular stimulation. IEEE Trans Biomed Eng. 1989;36(7):761-770. [PMID:2787284]http://dx.doi.org/10.1109/10.32109.
-
(1989)
IEEE Trans Biomed Eng
, vol.36
, Issue.7
, pp. 761-770
-
-
Kilgore, K.L.1
Peckham, P.H.2
Thrope, G.B.3
Keith, M.W.4
Galla-her-Stone, K.A.5
-
16
-
-
0036727084
-
The Fugl-Meyer assessment of motor recovery after stroke: A critical review of its measurement properties
-
[PMID:12234086]
-
Gladstone DJ, Danells CJ, Black SE. The Fugl-Meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurorehabil Neural Repair. 2002;16(3):232-240. [PMID:12234086]http://dx.doi.org/10.1177/154596802401105171.
-
(2002)
Neurorehabil Neural Repair
, vol.16
, Issue.3
, pp. 232-240
-
-
Gladstone, D.J.1
Danells, C.J.2
Black, S.E.3
-
18
-
-
33947603229
-
Improving hand function in stroke survivors: A pilot study of contralaterally controlled functional electric stimulation in chronic hemi-plegia
-
[PMID:17398254]
-
Knutson JS, Harley MY, Hisel TZ, Chae J. Improving hand function in stroke survivors: a pilot study of contralaterally controlled functional electric stimulation in chronic hemi-plegia. Arch Phys Med Rehabil. 2007;88(4):513-520. [PMID:17398254]http://dx.doi.org/10.1016/j.apmr.2007.01.003.
-
(2007)
Arch Phys Med Rehabil
, vol.88
, Issue.4
, pp. 513-520
-
-
Knutson, J.S.1
Harley, M.Y.2
Hisel, T.Z.3
Chae, J.4
-
19
-
-
0028297054
-
Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuro-prosthesis
-
[PMID:8201183]
-
Wuolle KS, Van Doren CL, Thrope GB, Keith MW, Peck-ham PH. Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuro-prosthesis. J Hand Surg Am. 1994;19(2):209-218. [PMID:8201183]http://dx.doi.org/10.1016/0363-5023(94)90008-6.
-
(1994)
J Hand Surg Am
, vol.19
, Issue.2
, pp. 209-218
-
-
Wuolle, K.S.1
van Doren, C.L.2
Thrope, G.B.3
Keith, M.W.4
Peck-Ham, P.H.5
-
20
-
-
0021281230
-
Reliabil-ity and validity of grip and pinch strength evaluations
-
[PMID:6715829]
-
Mathiowetz V, Weber K, Volland G, Kashman N. Reliabil-ity and validity of grip and pinch strength evaluations. J Hand Surg Am. 1984;9(2):222-226. [PMID:6715829]
-
(1984)
J Hand Surg Am
, vol.9
, Issue.2
, pp. 222-226
-
-
Mathiowetz, V.1
Weber, K.2
Volland, G.3
Kashman, N.4
-
21
-
-
0030924386
-
The Arm Motor Ability Test: Reliability, validity, and sensitivity to change of an instrument for assessing disabilities in activities of daily living
-
[PMID:9196469]
-
Kopp B, Kunkel A, Flor H, Platz T, Rose U, Mauritz KH, Gresser K, McCulloch KL, Taub E. The Arm Motor Ability Test: reliability, validity, and sensitivity to change of an instrument for assessing disabilities in activities of daily living. Arch Phys Med Rehabil. 1997;78(6):615-620.[PMID:9196469]http://dx.doi.org/10.1016/S0003-9993(97)90427-5.
-
(1997)
Arch Phys Med Rehabil
, vol.78
, Issue.6
, pp. 615-620
-
-
Kopp, B.1
Kunkel, A.2
Flor, H.3
Platz, T.4
Rose, U.5
Mauritz, K.H.6
Gresser, K.7
McCulloch, K.L.8
Taub, E.9
-
22
-
-
84857313103
-
Contralaterally controlled functional electri-cal stimulation for upper extremity hemiplegia: An early-phase randomized clinical trial in subacute stroke patients
-
[PMID:21875892]
-
Knutson JS, Harley MY, Hisel TZ, Hogan SD, Maloney MM, Chae J. Contralaterally controlled functional electri-cal stimulation for upper extremity hemiplegia: an early-phase randomized clinical trial in subacute stroke patients. Neurorehabil Neural Repair. 2012;26(3):239-246.[PMID:21875892]http://dx.doi.org/10.1177/1545968311419301.
-
(2012)
Neurorehabil Neural Repair
, vol.26
, Issue.3
, pp. 239-246
-
-
Knutson, J.S.1
Harley, M.Y.2
Hisel, T.Z.3
Hogan, S.D.4
Maloney, M.M.5
Chae, J.6
-
23
-
-
82255161108
-
Estimating the minimal clin-ically important difference of an upper extremity recovery measure in subacute stroke patients
-
[PMID:22120029]
-
Arya KN, Verma R, Garg RK. Estimating the minimal clin-ically important difference of an upper extremity recovery measure in subacute stroke patients. Top Stroke Rehabil. 2011;18(6, Suppl 1):599-610. [PMID:22120029]http://dx.doi.org/10.1310/tsr18s01-599.
-
(2011)
Top Stroke Rehabil
, vol.18
, Issue.6 SUPPL 1
, pp. 599-610
-
-
Arya, K.N.1
Verma, R.2
Garg, R.K.3
-
24
-
-
0015787499
-
Proportionally controlled func-tional electrical stimulation of hand
-
[PMID:4269119]
-
Rebersek S, Vodovnik L. Proportionally controlled func-tional electrical stimulation of hand. Arch Phys Med Reha-bil. 1973;54(8):378-382. [PMID:4269119]
-
(1973)
Arch Phys Med Reha-bil
, vol.54
, Issue.8
, pp. 378-382
-
-
Rebersek, S.1
Vodovnik, L.2
-
25
-
-
0016675208
-
Electro-physiological orthosis for the upper extremity in hemiple-gia: Feasibility study
-
[PMID:1081869]
-
Merletti R, Acimovic R, Grobelnik S, Cvilak G. Electro-physiological orthosis for the upper extremity in hemiple-gia: feasibility study. Arch Phys Med Rehabil. 1975;56(12):507-513. [PMID:1081869]
-
(1975)
Arch Phys Med Rehabil
, vol.56
, Issue.12
, pp. 507-513
-
-
Merletti, R.1
Acimovic, R.2
Grobelnik, S.3
Cvilak, G.4
-
26
-
-
28544444354
-
High-frequency electrical conduc-tion block of mammalian peripheral motor nerve
-
[PMID:16124008]
-
Bhadra N, Kilgore KL. High-frequency electrical conduc-tion block of mammalian peripheral motor nerve. Muscle Nerve. 2005;32(6):782-790. [PMID:16124008]http://dx.doi.org/10.1002/mus.20428
-
(2005)
Muscle Nerve
, vol.32
, Issue.6
, pp. 782-790
-
-
Bhadra, N.1
Kilgore, K.L.2
|