A high-fidelity temperature distribution forecasting system for data centers

Author keywords

[No Author keywords available]

Indexed keywords

10 MINUTES; AVERAGE ERRORS; COMPUTATIONAL FLUID DYNAMICS MODELING; COMPUTING INFRASTRUCTURES; CYBER PHYSICALS; DATA CENTERS; FORECASTING SYSTEM; HIGH-FIDELITY; PRODUCTION DATA; REAL-TIME PREDICTION; SENSOR FEEDBACK; SENSOR MEASUREMENTS; TEMPERATURE EVOLUTION; TEMPERATURE FORECASTING; TEMPERATURE MODELING; TEMPERATURE MONITORING; THERMAL MONITORING; THERMODYNAMIC MODEL; TRANSIENT TEMPERATURE DISTRIBUTIONS; WIRELESS SENSING;

EID: 84874322361     PISSN: 10528725     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/RTSS.2012.73     Document Type: Conference Paper
Times cited : (50)

References (29)
  • 1
    • 84874335838 scopus 로고    scopus 로고
    • Data center professionals turn to highdensity computing as major boom continues
    • Aperture Research Institute
    • Aperture Research Institute, "Data center professionals turn to highdensity computing as major boom continues," Research Note, April 2007.
    • (2007) Research Note
  • 2
    • 84874295588 scopus 로고    scopus 로고
    • http://blog.wikimedia.org/2010/03/24/globaloutagecoolingfailureanddns/.
  • 4
    • 78650445483 scopus 로고    scopus 로고
    • Dynamic thermal man agement of air cooled data centers
    • C. Bash, C. Patel, and R. Sharma, "Dynamic thermal man agement of air cooled data centers," in ITherm, 2006.
    • (2006) ITherm
    • Bash, C.1    Patel, C.2    Sharma, R.3
  • 5
    • 85141274933 scopus 로고    scopus 로고
    • Cool job alloction: Measuring the power savings of placing jobs at cooling efficient locations in the data center
    • C. Bash and G. Forman, "Cool job alloction: Measuring the power savings of placing jobs at cooling efficient locations in the data center," in USENIX ATC, 2007.
    • (2007) USENIX ATC
    • Bash, C.1    Forman, G.2
  • 6
    • 33845897992 scopus 로고    scopus 로고
    • Making scheduling"cool": Temperature aware workload placement in data centers
    • J. Moore, J. Chasey, P. Ranganathanz, and R. Sharmaz, "Making scheduling"cool": Temperature aware workload placement in data centers," in USENIX ATC, 2005.
    • (2005) USENIX ATC
    • Moore, J.1    Chasey, J.2    Ranganathanz, P.3    Sharmaz, R.4
  • 7
    • 54249125817 scopus 로고    scopus 로고
    • Energy efficient thermalaware task scheduling for homogeneous high performance computing data centers: A cyber physical approach
    • Q. Tang, S. K. S. Gupta, and G. Varsamopoulos, "Energy efficient thermal aware task scheduling for homogeneous high performance computing data centers: A cyber physical approach," in IEEE Trans. Parallel Distrib. Sys., 2008.
    • (2008) IEEE Trans. Parallel Distrib. Sys.
    • Tang, Q.1    Gupta, S.K.S.2    Varsamopoulos, G.3
  • 10
    • 57749193513 scopus 로고    scopus 로고
    • Coracle: Predictive thermal management for data centers
    • L. Ramos and R. Bianchini, "Coracle: Predictive thermal management for data centers," in HPCA, 2008.
    • (2008) HPCA
    • Ramos, L.1    Bianchini, R.2
  • 11
    • 47749153403 scopus 로고    scopus 로고
    • Sensor based fast thermal evaluation model for energy ef ficient high performance datacenters
    • Q. Tang, T. Mukherjee, S. K. S. Gupta, and P. Cayton, "Sensor based fast thermal evaluation model for energy efficient high performance datacenters," in ICISIP, 2006.
    • (2006) ICISIP
    • Tang, Q.1    Mukherjee, T.2    Gupta, S.K.S.3    Cayton, P.4
  • 12
    • 84874295655 scopus 로고    scopus 로고
    • Weatherman: Automated, online, and predictive thermal mapping and management
    • J. Moore, J. Chasey, and P. Ranganathanz, "Weatherman: Automated, online, and predictive thermal mapping and management," in ICAC, 2006.
    • (2006) ICAC
    • Moore, J.1    Chasey, J.2    Ranganathanz, P.3
  • 14
    • 84874320174 scopus 로고    scopus 로고
    • Best practices for designing data centers with the infrastruxure inrow RC
    • J. Niemann, "Best practices for designing data centers with the infrastruxure inrow RC," Application note of American Power Conversion, 2006.
    • (2006) Application Note of American Power Conversion
    • Niemann, J.1
  • 15
    • 84874336718 scopus 로고    scopus 로고
    • Improving data center efficiency with rack or row cooling devices: Results of chill off 2" comparative testing
    • G. C. Bell, "Improving data center efficiency with rack or row cooling devices: Results of "chill off 2" comparative testing," Federal Energy Management Program, 2012.
    • (2012) Federal Energy Management Program
    • Bell, G.C.1
  • 19
    • 80051882727 scopus 로고    scopus 로고
    • Towards optimal sensor placement for hot server detection in data centers
    • X. Wang, X. Wang, G. Xing, J. Chen, C.X. Lin, and Y. Chen, "Towards optimal sensor placement for hot server detection in data centers," in ICDCS, 2011.
    • (2011) ICDCS
    • Wang, X.1    Wang, X.2    Xing, G.3    Chen, J.4    Lin, C.X.5    Chen, Y.6
  • 25
    • 84874322232 scopus 로고    scopus 로고
    • Tripp Lite, Inc., Portable AC Unit SRCOOL12K
    • Tripp Lite, Inc., Portable AC Unit SRCOOL12K.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.