Volumn 113, Issue 6, 2013, Pages

Lanthanum halide nanoparticle scintillators for nuclear radiation detection

Author keywords

[No Author keywords available]

Indexed keywords

INCIDENT RADIATION; INTRINSIC RESPONSE; LANTHANUM HALIDES; NANO-STRUCTURED; NUCLEAR RADIATIONS;

EID: 84874303311     PISSN: 00218979     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.4790867     Document Type: Article
Times cited : (16)

References (15)
  • 4
    • 79960675976 scopus 로고    scopus 로고
    • Detection of nuclear weapons and materials: Science, technologies, observations
    • Prepared for Members and Committees of Congress, June 4
    • J. Medalia, " Detection of nuclear weapons and materials: Science, technologies, observations.," Congressional Research Service, CRS Report for Congress, Report No. R401454, Prepared for Members and Committees of Congress, June 4 (2010).
    • (2010) Congressional Research Service, CRS Report for Congress, Report No. R401454
    • Medalia, J.1
  • 5
    • 33644511162 scopus 로고    scopus 로고
    • Version 2.7.0, Los Alamos National Laboratory, Los Alamos, NM, April, LA-CP-11-0438
    • MCNPx User's Manual, Version 2.7.0, edited by, D. B. Pelowitz, Los Alamos National Laboratory, Los Alamos, NM, April 2011, LA-CP-11-0438.
    • (2011) MCNPx User's Manual
    • Pelowitz, D.B.1
  • 6
    • 33846361064 scopus 로고    scopus 로고
    • Semiconductor quantum dot scintillator under gamma-ray irradiation
    • 10.1021/nl0620942
    • S. E. Létant and T. F. Wang, " Semiconductor quantum dot scintillator under gamma-ray irradiation.," Nano Lett. 6, 2877-2880 (2006). 10.1021/nl0620942
    • (2006) Nano Lett. , vol.6 , pp. 2877-2880
    • Létant, S.E.1    Wang, T.F.2
  • 7
    • 80055039763 scopus 로고    scopus 로고
    • Corning Incorporated, accessed July 16 2010
    • VYCOR® Brand Porous Glass 7930, Corning Incorporated, see http://www.corning.com/docs/specialtymaterials/pisheets/Vycor%207930.pdf, accessed July 16 2010 (2001).
    • (2001) VYCOR® Brand Porous Glass 7930
  • 9
    • 84874331627 scopus 로고    scopus 로고
    • Report PNNL-18181, PIET-48581-TM-037, Pacific Northwest National Laboratory, U.S. Department of Energy Contract No. DE-AC05-76RL03180, January. See, accessed September 30, 2012
    • R. T. Kouzes, R. L. Redding, E. K. Mace, and D. C. Stemswold, " Symetrica measurements at PNNL, Technical support for DoD radiological protection issues.," Report PNNL-18181, PIET-48581-TM-037, Pacific Northwest National Laboratory, U.S. Department of Energy Contract No. DE-AC05-76RL03180, January 2009. See http://www.pnl.gov/main/publications/ external/technical-reports/PNNL-18181.pdf, accessed September 30, 2012.
    • (2009) Symetrica Measurements at PNNL, Technical Support for DoD Radiological Protection Issues
    • Kouzes, R.T.1    Redding, R.L.2    Mace, E.K.3    Stemswold, D.C.4
  • 10
    • 84874341153 scopus 로고    scopus 로고
    • Recent advances in the development of large-area plastic gamma-ray spectrometers
    • Institute of Electrical and Electronics Engineers
    • C. J. Burt and D. Ramsden, " Recent advances in the development of large-area plastic gamma-ray spectrometers.," in NSS Dresden Conference Record (Institute of Electrical and Electronics Engineers, 2008).
    • (2008) NSS Dresden Conference Record
    • Burt, C.J.1    Ramsden, D.2
  • 11
    • 11844299095 scopus 로고    scopus 로고
    • The effect of counting statistics on the integrity of deconvolved gamma-ray spectra
    • IEEE, Piscataway, New Jersey
    • G. Crossingham, M. Dallimore, and D. Ramsden, " The effect of counting statistics on the integrity of deconvolved gamma-ray spectra.," in Nuclear Science Symposium Conference Record (IEEE, Piscataway, New Jersey, 2003), Vol. 1, pp. 696-700.
    • (2003) Nuclear Science Symposium Conference Record , vol.1 , pp. 696-700
    • Crossingham, G.1    Dallimore, M.2    Ramsden, D.3
  • 12
    • 11944267367 scopus 로고    scopus 로고
    • High-resolution scintillation spectrometers for neutron-activation analysis
    • IEEE, Piscataway, New Jersey
    • M. Dallimore, G. Crossingham, and D. Ramsden, " High-resolution scintillation spectrometers for neutron-activation analysis.," in Nuclear Science Symposium Conference Record (IEEE, Piscataway, New Jersey, 2003), Vol. 2, pp. 704-707.
    • (2003) Nuclear Science Symposium Conference Record , vol.2 , pp. 704-707
    • Dallimore, M.1    Crossingham, G.2    Ramsden, D.3
  • 13
    • 84874333015 scopus 로고    scopus 로고
    • Progress towards the development of practical scintillation counters based on SiPM devices
    • Institute of Electrical and Electronics Engineers
    • M. A. Foster and D. Ramsden, " Progress towards the development of practical scintillation counters based on SiPM devices.," in NSS Dresden Conference Record (Institute of Electrical and Electronics Engineers, 2008).
    • (2008) NSS Dresden Conference Record
    • Foster, M.A.1    Ramsden, D.2
  • 14
    • 0034245272 scopus 로고    scopus 로고
    • An inter-comparison of three spectral-deconvolution algorithms for gamma-ray spectroscopy
    • 10.1109/23.872973
    • L. J. Meng and D. Ramsden, " An inter-comparison of three spectral-deconvolution algorithms for gamma-ray spectroscopy.," IEEE Trans. Nucl. Sci. 47 (4), 1329-1335 (2000). 10.1109/23.872973
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.4 , pp. 1329-1335
    • Meng, L.J.1    Ramsden, D.2
  • 15
    • 67649219292 scopus 로고    scopus 로고
    • The development of large-area plastic gamma-ray spectrometers
    • (Institute of Electrical and Electronics Engineers, 19-25 October 2008) NSS '08
    • C. Burt and D. Ramsden, " The development of large-area plastic gamma-ray spectrometers.," Nuclear Science Symposium Conference Record (Institute of Electrical and Electronics Engineers, 19-25 October 2008) NSS '08. 1186-1190 (2008).
    • (2008) Nuclear Science Symposium Conference Record , pp. 1186-1190
    • Burt, C.1    Ramsden, D.2