메뉴 건너뛰기




Volumn 91, Issue 3, 2013, Pages 162-169

Preoperative three-dimensional model creation of magnetic resonance brain images as a tool to assist neurosurgical planning

Author keywords

Functional magnetic resonance imaging; Magnetic resonance imaging; Neurosurgery; Rapid prototyping; Stereolithography; Three dimensional printing

Indexed keywords

ARTICLE; BRAIN DAMAGE; CASE REPORT; DIMENSIONAL MEASUREMENT ACCURACY; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; IN VIVO STUDY; NEUROSURGERY; NUCLEAR MAGNETIC RESONANCE SCANNER; PREOPERATIVE EVALUATION; THREE DIMENSIONAL IMAGING; BRAIN CORTEX; BRAIN TUMOR; COMPUTER PROGRAM; COST EFFECTIVENESS ANALYSIS; GRAY MATTER; IMAGING PHANTOM; MEASUREMENT ACCURACY; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; THREE DIMENSIONAL PRINTING; TREATMENT PLANNING;

EID: 84874244712     PISSN: 10116125     EISSN: 14230372     Source Type: Journal    
DOI: 10.1159/000345264     Document Type: Article
Times cited : (64)

References (34)
  • 2
    • 84878448333 scopus 로고    scopus 로고
    • Neurosurgical treatment planning; In Newton HB, Jolesz FA (eds): Handbook of Neuro-Oncology Neuroimaging
    • Tharin S, Golby A: Neurosurgical treatment planning; in Newton HB, Jolesz FA (eds): Handbook of Neuro-Oncology Neuroimaging. New York, Academic Press, 2008, pp 181-191.
    • (2008) New York, Academic Press , pp. 181-191
    • Tharin, S.1    Golby, A.2
  • 5
    • 35048839767 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging for preoperative localisation of eloquent brain areas relative to brain tumours: Clinical implementation in a regional hospital
    • Geerts J, Martens M, Vandevenne JE, Gelin G, Grieten M, Weyns F, Stinissen P, Palmers Y, Wuyts J: Functional magnetic resonance imaging for preoperative localisation of eloquent brain areas relative to brain tumours: clinical implementation in a regional hospital. JBR-BTR 2007; 90: 258-263.
    • (2007) JBR-BTR , vol.90 , pp. 258-263
    • Geerts, J.1    Martens, M.2    Vandevenne, J.E.3    Gelin, G.4    Grieten, M.5    Weyns, F.6    Stinissen, P.7    Palmers, Y.8    Wuyts, J.9
  • 6
    • 0030392070 scopus 로고    scopus 로고
    • Integration of MRI and stereolithography to build medical models: A case study
    • Swann S: Integration of MRI and stereolithography to build medical models: a case study. Rapid Prototyping J 1996; 2: 41-46.
    • (1996) Rapid Prototyping J , vol.2 , pp. 41-46
    • Swann, S.1
  • 11
    • 0033777846 scopus 로고    scopus 로고
    • A review of rapid prototyping (RP) techniques in the medical and biomedical sector
    • Webb PA: A review of rapid prototyping (RP) techniques in the medical and biomedical sector. J Med Eng Technol 2000; 24: 149-153.
    • (2000) J Med Eng Technol , vol.24 , pp. 149-153
    • Webb, P.A.1
  • 12
    • 18144440405 scopus 로고    scopus 로고
    • The application of rapid prototyping technologies in cranial reconstruction and preoperative planning in neurosurgery
    • Müller A, Krishnan KG, Uhl E, Mast G: The application of rapid prototyping technologies in cranial reconstruction and preoperative planning in neurosurgery. J Craniofac Surg 2003; 14: 899-914.
    • (2003) J Craniofac Surg , vol.14 , pp. 899-914
    • Müller, A.1    Krishnan, K.G.2    Uhl, E.3    Mast, G.4
  • 15
    • 21244466455 scopus 로고    scopus 로고
    • Medical rapid prototyping technologies: State of the art and current limitations for applications in oral and maxillofacial surgery
    • Winder J, Bibb R: Medical rapid prototyping technologies: state of the art and current limitations for applications in oral and maxillofacial surgery. J Oral Maxillofac Surg 2005; 63: 1006-1015.
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 1006-1015
    • Winder, J.1    Bibb, R.2
  • 16
    • 26944498616 scopus 로고    scopus 로고
    • Diffusion tensor tractography in patients with cerebral tumors: A helpful technique for neurosurgical planning and postoperative assessment
    • Yu CS, Li KC, Xuan Y, Ji XM, Qin W: Diffusion tensor tractography in patients with cerebral tumors: a helpful technique for neurosurgical planning and postoperative assessment. Eur J Radiol 2005; 56: 197-204.
    • (2005) Eur J Radiol , vol.56 , pp. 197-204
    • Yu, C.S.1    Li, K.C.2    Xuan, Y.3    Ji, X.M.4    Qin, W.5
  • 17
    • 20344376911 scopus 로고    scopus 로고
    • Color rapid prototyping for diffusion tensor MRI visualization
    • Saint-Malo, September
    • Acevedo D, Zhang S, Laidlaw DH, Bull CW: Color rapid prototyping for diffusion tensor MRI visualization. Proc MICCAI, Saint-Malo, September 2004, pp 1076-1078.
    • (2004) Proc MICCAI , pp. 1076-1078
    • Acevedo, D.1    Zhang, S.2    Laidlaw, D.H.3    Bull, C.W.4
  • 18
    • 31544445821 scopus 로고    scopus 로고
    • Rapid vessel prototyping: Vascular modeling using 3T magnetic resonance angiography and rapid prototyping technology
    • Markl M, Schumacher R, Küffer J, Bley TA, Hennig J: Rapid vessel prototyping: vascular modeling using 3T magnetic resonance angiography and rapid prototyping technology. MAGMA 2005; 18: 288-292.
    • (2005) MAGMA , vol.18 , pp. 288-292
    • Markl, M.1    Schumacher, R.2    Küffer, J.3    Bley, T.A.4    Hennig, J.5
  • 19
    • 0025034429 scopus 로고
    • Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE)
    • Mugler JP III, Brookeman JR: Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn Reson Med 1990; 15: 152-157.
    • (1990) Magn Reson Med , vol.15 , pp. 152-157
    • Mugler, J.P.I.I.I.1    Brookeman, J.R.2
  • 21
    • 0041901540 scopus 로고    scopus 로고
    • Concepts for rapid application prototyping in medical image analysis and visualization
    • Ghent, March
    • Hahn HK, Link F, Peitgen H: Concepts for rapid application prototyping in medical image analysis and visualization. Proc Simulation Visualisierung, Ghent, March 2003, pp 283-298.
    • (2003) Proc Simulation Visualisierung , pp. 283-298
    • Hahn, H.K.1    Link, F.2    Peitgen, H.3
  • 22
    • 4644278739 scopus 로고    scopus 로고
    • Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images
    • Janke A, Zhao H, Cowin GJ, Galloway GJ, Doddrell GM: Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magn Reson Med 2004; 52: 115-122.
    • (2004) Magn Reson Med , vol.52 , pp. 115-122
    • Janke, A.1    Zhao, H.2    Cowin, G.J.3    Galloway, G.J.4    Doddrell, G.M.5
  • 23
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard P, Balaban RS: Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 1995; 34: 65-73.
    • (1995) Magn Reson Med , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 24
    • 85026150644 scopus 로고    scopus 로고
    • The accuracy of stereolithography in planning craniofacial bone replacement
    • Chang PS, Patrick TH, Patrick CW Jr, Miller MJ: The accuracy of stereolithography in planning craniofacial bone replacement. J Craniofac Surg 2003; 14: 164-170.
    • (2003) J Craniofac Surg , vol.14 , pp. 164-170
    • Chang, P.S.1    Patrick, T.H.2    Patrick Jr., C.W.3    Miller, M.J.4
  • 26
    • 46949085594 scopus 로고    scopus 로고
    • Computer-assisted stereotactic neurosurgery with framework neurosurgery navigation
    • Fengqiang L, Jiadong Q, Yi L: Computer-assisted stereotactic neurosurgery with framework neurosurgery navigation. Clin Neurol Neurosurg 2008; 110: 696-700.
    • (2008) Clin Neurol Neurosurg , vol.110 , pp. 696-700
    • Fengqiang, L.1    Jiadong, Q.2    Yi, L.3
  • 28
    • 59449104777 scopus 로고    scopus 로고
    • Rapid prototyping of compliant human aortic roots for assessment
    • Kalejs M, von Segesser LK: Rapid prototyping of compliant human aortic roots for assessment. Interact Cardiovasc Thorac Surg 2008; 8: 182-186.
    • (2008) Interact Cardiovasc Thorac Surg , vol.8 , pp. 182-186
    • Kalejs, M.1    Von Segesser, L.K.2
  • 29
    • 82455194983 scopus 로고    scopus 로고
    • Accuracy of rapid prototype models for head and neck reconstruction
    • Taft RM, Kondor S, Grant GT: Accuracy of rapid prototype models for head and neck reconstruction. J Prosthet Dent 2011; 106: 399-408.
    • (2011) J Prosthet Dent , vol.106 , pp. 399-408
    • Taft, R.M.1    Kondor, S.2    Grant, G.T.3
  • 30
    • 33646035187 scopus 로고    scopus 로고
    • Rapid prototyping as a tool for diagnosis and treatment planning for maxillary canine impaction
    • Faber J, Berto PM, Quaresma M: Rapid prototyping as a tool for diagnosis and treatment planning for maxillary canine impaction. Am J Orthod Dentofacial Orthop 2006; 129: 583-589.
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 583-589
    • Faber, J.1    Berto, P.M.2    Quaresma, M.3
  • 33
    • 80053384750 scopus 로고    scopus 로고
    • Organ printing: From bioprinter to organ biofabrication line
    • Mironov V, Kasyanov V, Markwald RR: Organ printing: from bioprinter to organ biofabrication line. Curr Opin Biotechnol 2011; 22: 667-673.
    • (2011) Curr Opin Biotechnol , vol.22 , pp. 667-673
    • Mironov, V.1    Kasyanov, V.2    Markwald, R.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.