메뉴 건너뛰기




Volumn 135, Issue 3, 2013, Pages

In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices

Author keywords

axial flow blood pump; centrifugal flow blood pump; left ventricular assist device; mechanical circulatory support; pulsatility

Indexed keywords

AXIAL FLOW BLOOD PUMPS; AXIAL FLOW PUMP; AXIAL PUMPS; BLOOD PUMP; CIRCULATORY FLOW; CONTINUOUS-FLOW; HEART FAILURE; IMPELLER SPEED; IN-VITRO; MECHANICAL CIRCULATORY SUPPORT; PULSATILITY; PULSATILITY INDEX; VENTRICULAR ASSIST DEVICE;

EID: 84874093927     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4023525     Document Type: Article
Times cited : (23)

References (27)
  • 1
    • 0001168111 scopus 로고
    • Perfusion of the pulmonary circulation by nonpulsatile flow
    • Wesolowski, S. A., Fisher, J. H., and Welsh, C. S., 1953, " Perfusion of the Pulmonary Circulation by Nonpulsatile Flow.," Surgery, 33 (3), pp. 370-375.
    • (1953) Surgery , vol.33 , Issue.3 , pp. 370-375
    • Wesolowski, S.A.1    Fisher, J.H.2    Welsh, C.S.3
  • 2
    • 0026647115 scopus 로고
    • Is a pulsatile cardiac prosthesis a dying dinosaur?
    • Nose, Y., 1992, " Is a Pulsatile Cardiac Prosthesis a Dying Dinosaur? " Artif. Organs, 16 (3), pp. 233-234.
    • (1992) Artif. Organs , vol.16 , Issue.3 , pp. 233-234
    • Nose, Y.1
  • 3
    • 0028332172 scopus 로고
    • Pulsatile versus nonpulsatile cardiopulmonary bypass: No difference in brain blood flow or metabolism at 27 °c
    • Hindman, B. J., Dexter, F., Ryu, K. H., Smith, T., and Cutkomp, J., 1994, " Pulsatile versus Nonpulsatile Cardiopulmonary Bypass: No Difference in Brain Blood Flow or Metabolism at 27 °C.," Anesthesiology, 80 (5), pp. 1137-1147, Available at: http://journals.lww.com/anesthesiology/Abstract/1994/ 05000/Pulsatile-Versus-Nonpulsatile-Cardiopulmonary.23.aspx
    • (1994) Anesthesiology , vol.80 , Issue.5 , pp. 1137-1147
    • Hindman, B.J.1    Dexter, F.2    Ryu, K.H.3    Smith, T.4    Cutkomp, J.5
  • 6
    • 0023919392 scopus 로고
    • The need for a nonpulsatile pumping system
    • Nose, Y., 1988, " The Need for a Nonpulsatile Pumping System.," Artif. Organs, 12 (2), pp. 113-115.
    • (1988) Artif. Organs , vol.12 , Issue.2 , pp. 113-115
    • Nose, Y.1
  • 7
    • 84970399852 scopus 로고
    • Review article: Current status and use of artificial hearts and circulatory assist devices
    • Unger, F., 1986, " Review Article: Current Status and Use of Artificial Hearts and Circulatory Assist Devices.," Perfusion, 1 (3), pp. 155-163.
    • (1986) Perfusion , vol.1 , Issue.3 , pp. 155-163
    • Unger, F.1
  • 8
    • 0033945443 scopus 로고    scopus 로고
    • The history of continuous-flow blood pumps
    • Olsen, D. B., 2000, " The History of Continuous-Flow Blood Pumps.," Artif. Organs, 24 (6), pp. 401-404.
    • (2000) Artif. Organs , vol.24 , Issue.6 , pp. 401-404
    • Olsen, D.B.1
  • 9
    • 0030740053 scopus 로고    scopus 로고
    • The importance of pulsatile and nonpulsatile flow in the design of blood pumps
    • Allen, G. S., Murray, K. D., and Olsen, D. B., 1997, " The Importance of Pulsatile and Nonpulsatile Flow in the Design of Blood Pumps.," Artif. Organs, 21 (8), pp. 922-928.
    • (1997) Artif. Organs , vol.21 , Issue.8 , pp. 922-928
    • Allen, G.S.1    Murray, K.D.2    Olsen, D.B.3
  • 12
    • 0035337515 scopus 로고    scopus 로고
    • Sensorless approach to control of a turbodynamic lvas
    • Choi, S., Antaki, J. F., Boston, J. R., and Thomas, D. A., 2001, " Sensorless Approach to Control of a Turbodynamic LVAS.," IEEE T. Contr. Syst. T., 9 (3), pp. 473-482.
    • (2001) IEEE T. Contr. Syst. T. , vol.9 , Issue.3 , pp. 473-482
    • Choi, S.1    Antaki, J.F.2    Boston, J.R.3    Thomas, D.A.4
  • 13
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an adult mock circulation for testing cardiac support devices
    • Pantalos, G. M., Koenig, S. C., Gillars, K. J., Giridharan, G. A., and Ewert, D. L., 2004, " Characterization of an Adult Mock Circulation for Testing Cardiac Support Devices.," ASAIO J., 50 (1), pp. 37-46.
    • (2004) ASAIO J. , vol.50 , Issue.1 , pp. 37-46
    • Pantalos, G.M.1    Koenig, S.C.2    Gillars, K.J.3    Giridharan, G.A.4    Ewert, D.L.5
  • 14
    • 84868660683 scopus 로고    scopus 로고
    • Flow characteristics of continuous-flow lvads in a novel open-loop system
    • Stanfield, J. R., Selzman, C. H., Pardyjak, E. R., and Bamberg, S. M., 2012, " Flow Characteristics of Continuous-Flow LVADs in a Novel Open-Loop System.," ASAIO J., 58 (6), pp. 590-596.
    • (2012) ASAIO J. , vol.58 , Issue.6 , pp. 590-596
    • Stanfield, J.R.1    Selzman, C.H.2    Pardyjak, E.R.3    Bamberg, S.M.4
  • 15
    • 84870449174 scopus 로고    scopus 로고
    • Pressure sensitivity of axial-flow and centrifugal-flow lvads
    • Stanfield, J. R., and Selzman, C. H., 2012, " Pressure Sensitivity of Axial-Flow and Centrifugal-Flow LVADs.," Cardiovasc. Eng. Tech., 3 (4), pp. 413-423.
    • (2012) Cardiovasc. Eng. Tech. , vol.3 , Issue.4 , pp. 413-423
    • Stanfield, J.R.1    Selzman, C.H.2
  • 16
    • 14844344055 scopus 로고    scopus 로고
    • An investigation of the pump operating characteristics as a novel control index for lvad control
    • Choi, S., Boston, J. R., and Antaki, J. F., 2005, " An Investigation of the Pump Operating Characteristics as a Novel Control Index for LVAD Control.," Int. J. Cont. Autom., 3 (1), pp. 100-108, Available at: http://bme2.aut.ac.ir/~towhidkhah/BioModelling/Seminar87-1/rohani/ An%20investigation%20of%20the%20pump%20operating%20characteristics%20as%20a%20n ovel%20control%20index%20for%20LVAD%20control.pdf
    • (2005) Int. J. Cont. Autom. , vol.3 , Issue.1 , pp. 100-108
    • Choi, S.1    Boston, J.R.2    Antaki, J.F.3
  • 17
    • 33846960118 scopus 로고    scopus 로고
    • Hemodynamic controller for lvad based on pulsatility ratio
    • Choi, S., Boston, J. R., and Antaki, J. F., 2007, " Hemodynamic Controller for LVAD Based on Pulsatility Ratio.," Artif. Organs, 31 (2), pp. 114-125.
    • (2007) Artif. Organs , vol.31 , Issue.2 , pp. 114-125
    • Choi, S.1    Boston, J.R.2    Antaki, J.F.3
  • 20
  • 22
    • 0842286457 scopus 로고    scopus 로고
    • In vitro characterization of aortic retrograde and antegrade flow from pulsatile and nonpulsatile vads
    • DiGiorgi, P. L., Smith, D. L., Naka, Y., and Oz, M. C., 2004, " In Vitro Characterization of Aortic Retrograde and Antegrade Flow From Pulsatile and Nonpulsatile VADs.," J. Heart Lung Transpl., 23 (2), pp. 186-192.
    • (2004) J. Heart Lung Transpl. , vol.23 , Issue.2 , pp. 186-192
    • Digiorgi, P.L.1    Smith, D.L.2    Naka, Y.3    Oz, M.C.4
  • 23
    • 0030018274 scopus 로고    scopus 로고
    • Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock
    • Nakata, K., Shiono, M., Orime, Y., Hata, M., Sezai, A., Saitoh, T., and Sezai, Y., 1996, " Effect of Pulsatile and Nonpulsatile Assist on Heart and Kidney Microcirculation With Cardiogenic Shock.," Artif. Organs, 20 (6), pp. 681-684.
    • (1996) Artif. Organs , vol.20 , Issue.6 , pp. 681-684
    • Nakata, K.1    Shiono, M.2    Orime, Y.3    Hata, M.4    Sezai, A.5    Saitoh, T.6    Sezai, Y.7
  • 25
    • 0035100480 scopus 로고    scopus 로고
    • Healing the heart with vad therapy: Mechanisms of cardiac recovery
    • Young, J. B., 2001, " Healing the Heart With VAD Therapy: Mechanisms of Cardiac Recovery." Ann. Thorac. Surg., 71 (3 Suppl.), pp. S210-S219.
    • (2001) Ann. Thorac. Surg. , vol.71 , Issue.3 SUPPL.
    • Young, J.B.1
  • 26
    • 0029033797 scopus 로고
    • Reversal of chronic ventricular dilatation in patients with end-stage cardiomyopathy by prolonged mechanical unloading
    • Levin, H., Oz, M., Chen, J., Packer, M., Rose, E., and Burkhoff, D., 1995, " Reversal of Chronic Ventricular Dilatation in Patients With End-Stage Cardiomyopathy by Prolonged Mechanical Unloading.," Circulation, 91 (11), pp. 2717-2720.
    • (1995) Circulation , vol.91 , Issue.11 , pp. 2717-2720
    • Levin, H.1    Oz, M.2    Chen, J.3    Packer, M.4    Rose, E.5    Burkhoff, D.6
  • 27
    • 34249011417 scopus 로고    scopus 로고
    • Design features, developmental status and experimental results with the heartmate iii centrifugal lvas with magnetically levitated rotor
    • Farrar, D. J., Bourque, K., Dague, C. P., Cotter, C. J., and Poirier, V. L., 2007, " Design Features, Developmental Status and Experimental Results With the Heartmate III Centrifugal LVAS With Magnetically Levitated Rotor.," ASAIO J., 53 (3), pp. 310-315.
    • (2007) ASAIO J. , vol.53 , Issue.3 , pp. 310-315
    • Farrar, D.J.1    Bourque, K.2    Dague, C.P.3    Cotter, C.J.4    Poirier, V.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.